OWNER’S MANUAL
OPERATING
FIREPLACE
Continued
OPTIONAL REMOTE
OPERATION
Note: The GHRC receiver and hand- held remote control accessory must be purchased separately (See Accessories on pages 32 and 33). Follow instructions in- cluded with the remote control.
NOTICE: You must light the pilot before using the
1. After lighting, let pilot flame burn for |
about one minute. Turn gas control |
knob on the control valve to ON posi- |
tion. Turn variable control knob any- |
where between HI and LO. Slide the |
selector switch to the REMOTE po- |
sition. Note: The burner may light if |
when selector switch was last turned |
off. You can now turn the burners on |
and off with the |
trol unit. |
OPERATING
OPTIONAL BLOWER
ACCESSORY
Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the left side of the switch bracket to the left just inside the louver panel.
Both the GA3700 manual blower and the DA3610T
Note for CDA3610T Only: If you are using CDA3610T blower, your fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.
The blower helps distribute heated air from the fireplace. Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions that will hinder the flow of air.
INSPECTING
BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT ASSEMBLY
The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. Call a qualified service person to readjust the pilot if necessary.
The height of the thermopile must be 3/8" to 1/2" above the pilot flame as shown in Figure
55.The thermocouple must be at a height of about 1/8" above the pilot flame. The flame from the pilot burner must extend beyond both the thermocouple and thermopile.
If your pilot assembly does not meet these requirements:
•turn fireplace off (seeTo Turn Off Gas to Appliance, page 24)
•seeTroubleshooting, pages 27 through 29
Thermopile
3/8" to 1/2"
Pilot Burner
IMPORTANT: Do not leave the se- |
lector switch in the REMOTE posi- |
tion when the pilot is not lit. This will |
drain the battery. |
IMPORTANT: Be sure to press the |
ON/OFF button on the |
mote control unit for up to 3 seconds |
to assure proper operation. |
2. Press the ON/OFF button to turn the |
burners on and off. When turning |
burners off, the pilot will remain lit. |
IMPORTANT: To turn the pilot off, |
manually turn the gas control knob |
Blower Control Knob (Optional Accessory)
OFF
ON
REMOTE
OFF
ON
Selector Switch in
Remote Position
(Optional Remote
Control)
Variable Control Knob
N |
| L |
|
O |
| O | I |
T | F | O | H |
O | F |
|
|
LIP |
|
|
|
|
|
|
|
Gas Control
Knob in On
Position
1/8"
Thermocouple
Piezo
Ignitor
Figure 55 - Pilot Assembly
on the heater to the OFF position. |
Figure 54 - Setting the Selector Switch, Gas Control Knob, and Variable Control Knob for Remote Operation
Continued
105980 | 25 |