Desa BDV34NA, BDV34PA installation manual Gas leak. See Warning statement

Page 29

OWNER’S MANUAL

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

Fireplace produces unwanted odors

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks (see Check-

 

 

 

above

 

ing Gas Connections, pages 19 and 20)

 

 

 

 

 

 

 

Fireplace shuts off in use

1.

High or gusting winds

1.

Fireplace has been tested for up to

 

 

 

 

 

40mph winds. However, extreme con-

 

 

 

 

 

ditions may occur. See Lighting Instruc-

 

 

 

 

 

tions on page 24

 

 

2.

Low line pressure

2.

Contact local propane/LP or natural gas

 

 

 

 

 

company

 

 

3.

Pilot is partially clogged

3.

Clean pilot (see Cleaning and Mainte-

 

 

 

 

 

nance, page 26)

 

 

4.

Inner vent pipe leaking exhaust gasses

4.

Locate and correct all leaks (see Check-

 

 

 

into system

 

ing Gas Connections, pages 19 and 20)

 

 

5.

Horizontal vent improperly pitched

5.

Horizontal vent termination should slope

 

 

 

 

 

down only enough to prevent any water

 

 

 

 

 

from entering the unit. The maximum

 

 

 

 

 

downward slope of the vent termination

 

 

 

 

 

is 1/4" for any horizontal run

 

 

6.

Glass too loose and air tight gasket leaks

6.

Tighten glass

 

 

 

in corners after usage

 

 

 

 

 

7.

Bad thermopile or thermocouple

7.

Replace faulty component

 

 

8.

Improper vent cap installation

8.

Check for proper installation and free-

 

 

 

 

 

dom from debris or blockage

 

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks (see Check-

position

 

above

 

ing Gas Connections, pages 19 and 20)

 

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

 

 

Gas odor during combustion

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks (see Check-

 

 

 

above

 

ing Gas Connections, pages 19 and 20)

 

 

 

 

 

 

 

Dark residue on logs or inside of fireplace

1.

Improper log placement

1.

Properly locate logs (see Installing Logs,

 

 

 

 

 

Lava Rock, and Glowing Embers, page 23)

 

 

2.

Air holes at burner inlet blocked

2.

Clean out air holes at burner inlets. Pe-

 

 

 

 

 

riodically repeat as needed

 

 

3.

Burner flame holes blocked

3.

Remove blockage or replace burner

www.desatech.com

105980

29

Image 29
Contents Natural GAS Model BDV34NA PROPANE/LP GAS Model BDV34PA For Your SafetyFor Your Safety What to do if YOU Smell GAS BDV34NA and BDV34PA Safety InformationProduct Identification Product FeaturesGlossary Terms Local CodesLocation and Space Requirements PRE-INSTALLATION PreparationClearances Framing and FinishingLocation of Vent Termination PRE-INSTALLATION Preparation General VentingGeneral Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Cathedral Ceiling Installation Installation for Vertical TerminationFlat Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting Parts Lists for Venting Kits and Components High Altitude InstallationVanguard Rigid Venting Vanguard Flexible VentingInstalling Optional Blower Accessory Fireplace InstallationInstalling GA3700/DA3610T Blowers Check GAS TypeSide View Installation Items Needed Installing GAS Piping to Fireplace LocationChecking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas Connections Installing Optional Wall Mount Switch GWMS2REMOVING/REPLACING Glass Door Installing Remote ReceiverInstalling Left Side Brick Panel Installing Optional Brick Liner D8037AInstalling Log No Installing LOGS, Lava Rock and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsPilot Assembly Operating Optional Blower AccessoryInspecting Burners Optional Remote OperationCleaning and Maintenance Observed Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Replacement PartsTechnical Service Service HintsBDV34NA BDV34PA SpecificationsAccessories Duplex Outlet KIT Receiver and HAND-HELD Remote Control KIT Ghrc SeriesManual Blower KIT GA3700 Brass Louver KITBDV34NA7 BDV34PA Illustrated PARTS37 BreakdownDIRECT-VENT Fireplace BDV34NA BDV34PA Parts ListWarranty Information