Desa BDV34NA, BDV34PA installation manual REMOVING/REPLACING Glass Door, Installing Remote Receiver

Page 21

OWNER’S MANUAL

FIREPLACE INSTALLATION

Continued

INSTALLING OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL ACCESSORY - GHRC

NOTICE: Use only alkaline bat- teries (not included).

Installing Remote Receiver

1.Open bottom louver and locate the switch bracket on the left.

2.Unscrew the switch bracket. Lean bracket forward so you are able to ac- cess the back of the remote receiver.

3.Locate the battery clip mounted on the back of the receiver. Slide a 9-volt al- kaline battery (not included) through the clip.

4.Attach the terminal wires to the battery.

5.Remove the wire that runs from TH to TPTH from the valve (see Figure 40).

6.Connect wires from receiver to TH and TPTH on the valve (see Figure 41).

7.Replace the switch bracket.

Figure 40 - Disconnecting TH to TPTH Wire

To Wall Optional

Remote Accessory

t

Figure 41 - Control Valve Terminals

Receiver

Terminal

Wires

Battery Clip

9-Volt Alkaline Battery

Figure 42 - Attaching Alkaline Battery to Receiver

Installing 9-Volt Alkaline Battery

in Hand-Held Remote Control

Unit

1.Remove battery cover on back of re- mote control unit.

2.Attach terminal wires to a 9-volt bat- tery (not included). Place battery into the battery housing.

3.Replace battery cover onto remote con- trol unit.

Battery Cover

Remote

Terminal

Control Unit

Wires

 

9-Volt

 

Alkaline

 

Battery

 

 

Battery

 

Housing

Figure 43 - Installing Alkaline Battery in Hand-Held Remote Control Unit

REMOVING/REPLACING GLASS DOOR

You must remove glass door to install op- tional brick liners, logs, lava rock, and em- ber material.

CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For re- placement part information see Replacement Parts, page 30.

1.Remove the upper louver panel by lift- ing upward and out (see Figure 44).

2.Remove the screws from the three tabs at the top of the glass door while hold- ing door securely keeping it from fall- ing forward.

3.Grasp door by both sides and ease it upward off of the lower bracket (see Figure 45).

4.To replace glass door, follow the above instructions in reverse.

Top Louver

Panel

Figure 44 - Removing Top Louver Panel

Screw

Glass Door

Assembly

Lower Bracket for

Glass Door Assembly

Figure45 -Removing/ReplacingGlassDoor

Continued

105980

21

Image 21
Contents For Your Safety For Your Safety What to do if YOU Smell GASNatural GAS Model BDV34NA PROPANE/LP GAS Model BDV34PA BDV34NA and BDV34PA Safety InformationProduct Identification Product FeaturesGlossary Terms Local CodesLocation and Space Requirements PRE-INSTALLATION PreparationClearances Framing and FinishingLocation of Vent Termination PRE-INSTALLATION Preparation General VentingGeneral Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting Parts Lists for Venting Kits and Components High Altitude InstallationVanguard Rigid Venting Vanguard Flexible VentingInstalling Optional Blower Accessory Fireplace InstallationInstalling GA3700/DA3610T Blowers Check GAS TypeSide View Installation Items Needed Installing GAS Piping to Fireplace LocationConnecting Fireplace to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Pressure Testing Fireplace Gas Connections Installing Optional Wall Mount Switch GWMS2REMOVING/REPLACING Glass Door Installing Remote ReceiverInstalling Left Side Brick Panel Installing Optional Brick Liner D8037AInstalling Log No Installing LOGS, Lava Rock and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsPilot Assembly Operating Optional Blower AccessoryInspecting Burners Optional Remote OperationCleaning and Maintenance Observed Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Replacement PartsTechnical Service Service HintsBDV34NA BDV34PA SpecificationsAccessories Duplex Outlet KIT Receiver and HAND-HELD Remote Control KIT Ghrc SeriesManual Blower KIT GA3700 Brass Louver KITBDV34NA7 BDV34PA Illustrated PARTS37 BreakdownDIRECT-VENT Fireplace BDV34NA BDV34PA Parts ListWarranty Information