Desa BDV34NA, BDV34PA High Altitude Installation, Parts Lists for Venting Kits and Components

Page 15

OWNER’S MANUAL

VENTING INSTALLATION

Continued

HIGH ALTITUDE

INSTALLATION

Your Vanguard direct-vent fireplace has been AGA tested and approved for eleva- tions from 0-2000 feet and CGA certified for elevations from 0-4500 feet.

When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Re- duce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification.

When installing this fireplace at an eleva- tion above 4500 feet (in Canada), check with local authorities.

Consult your local gas company to help de- termine the proper orifice for your location.

For assistance with any high altitude instal- lation contact DESA International’s Tech- nical Service Department at 1-800-DESA- LOG (1-800-337-2564).

PARTS LISTS FOR VENTING KITS AND COMPONENTS

Vanguard Rigid Venting

Number Description

BGFVK Basic Ground Floor Rigid Vent Kit

Includes: 7" x 60° Elbow, Extended

Adjustable Horizontal Termination,

Wall Thimble and 14 Screws

BVK

Basement Rigid Vent Kit

 

Includes: 7" x 30° Elbow, 7" x 4'

 

Galvanized Pipe, 7" x 90° Elbow, 7"

 

Adjustable Galvanized Pipe (7-12"),

 

Wall Thimble, Horizontal Termina-

 

tion, RTV Silicone and 20 Screws

CVK

Corner Vent Kit

 

Includes: 7" x 30° Elbow, 7" x 90°

 

Elbow, 7" Adjustable Galvanized

 

Pipe (7-12"), 6" Pipe, Wall Thimble,

 

Horizontal Termination, RTV Sili-

 

cone and 20 Screws

SVK

Snorkel Rigid Vent Kit

 

Includes: 7" x 30° Elbow, 7" x 4'

 

Galvanized Pipe, 7" x 90° Elbow, 7"

 

Adjustable Galvanized Pipe (7-12"),

 

Wall Thimble, 36" Snorkel Termi-

 

nation, RTV Silicone and 28 Screws

Vanguard Rigid Venting (Cont.)

Number Description

RVF

Roof Rigid Vent Kit

 

Includes: Flue Restrictor, Storm

 

Collar, 7" x 30° Elbow, 7" x 4'

 

Galvanized Pipe, 7" x 2' Galva-

 

nized Pipe, 7" Adjustable Galva-

 

nized Pipe (7-12"), Firestop Sup-

 

port, Roof Flashing, RTV Silicone,

 

Vertical Termination, and 26 screws

D1000

7" x 12" Galvanized Coaxial

 

Pipe (6 pcs.)

D1010

7" x 24" Galvanized Coaxial

 

Pipe (6 pcs.)

D1020

7" x 48" Galvanized Coaxial

 

Pipe (6 pcs.)

D1030

7" Adjustable (7-12")

 

Galvanized Coaxial Pipe

 

(6 pcs.)

D1050

7" x 6" Galvanized Coaxial Pipe

 

(6 pcs.)

D2000

7" x 90° Elbow (6 pcs.)

D2010

7" x 45° Elbow (6 pcs.)

D2020

7" x 30° Elbow (6 pcs.)

D2030

7" x 60° Elbow (6 pcs.)

D3000

Wall Strap/Offset Support

 

(6 pcs.)

D3010

Storm Collar (6 pcs.)

D3020

Wall Thimble (6 pcs.)

D3040

Vertical Vent Termination Cap

D3050

Vertical Restrictor (6 pcs.)

D3060

Ceiling Firestop/Support (6 pcs.)

D3070

Rectangular Horizontal Rigid

 

Vent Termination Cap

D3090

Cathedral Ceiling Support Box

D4000

Roof Flashing 6/12-9/12

D4010

Roof Flashing 9/12-12/12

D5000

Wood/Vinyl Siding Standoff

 

(6 pcs.)

Vanguard Flexible Venting

Number Description

BFGFVK Basic Flex Ground Floor Vent Kit

Includes: Flex Adapter, 7" x 2' Flex- ible Pipe, 4" x 2' Flexible Pipe, Wall Thimble, Horizontal Termination, (2) Spacer Springs,

(2)4" Hose Clamps, (2) 7" Hose Clamps, and 10 Screws

Vanguard Flexible Venting (Cont.)

Number Description

FGFVK Flex Ground Floor Vent Kit

Includes: Flex Adapter, 7" x 4' Flex- ible Pipe, 4" x 4' Flexible Pipe, Wall Thimble, Horizontal Termination,

(4)Spacer Springs, (2) 4" Hose Clamps, (2) 7" Hose Clamps, RTV Silicone, and 10 Screws

D1040 7" x 25' Coaxial Flex Pipe with Spacer Springs

D3080 Rectangular Horizontal Flex

Termination Cap

D4020 Flex Connector (6 pcs.)

D4030 Flex Wall Thimble (6 pcs.)

D4040 4" Hose Clamp (6 pcs.)

D4050 7" Hose Clamp (6 pcs.)

SIMPSON DURA-VENT GS 4" x 6 5/8 "

Number Description

Available from DESA International:

SD2040 Simpson Dura-Vent GS 30° Elbow (6 pcs.)

SD2050 Simpson Dura-Vent GS 60° Elbow (6 pcs.)

Available from Simpson Dura-Vent Only:

9027" x 48" Pipe

9037" x 36" Pipe

9047" x 24" Pipe

9067" x 12" Pipe

9077" x 9" Pipe

9087" x 6" Pipe

9117" Adjustable (11"-14 5/8") Pipe

940Wall Thimble

941Cathedral Ceiling Support Box

943Roof Flashing 0/12-6/12

943S Roof Flashing 7/12-12/12

9457" x 45° Elbow

950Vinyl Siding Standoff

953Storm Collar

963Ceiling Firestop

98136" Snorkel Termination

984Horizontal Termination Vent Cap

988Wall Strap

9907" x 90° Elbow

991Vertical High Wind Termination

105980

15

Image 15
Contents For Your Safety For Your Safety What to do if YOU Smell GASNatural GAS Model BDV34NA PROPANE/LP GAS Model BDV34PA BDV34NA and BDV34PA Safety InformationLocal Codes Product FeaturesProduct Identification Glossary TermsFraming and Finishing PRE-INSTALLATION PreparationLocation and Space Requirements ClearancesLocation of Vent Termination PRE-INSTALLATION Preparation General VentingGeneral Venting Installing Vent System in a Chase Venting InstallationInstallation Precautions Installation PlanningSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting Vanguard Flexible Venting High Altitude InstallationParts Lists for Venting Kits and Components Vanguard Rigid VentingCheck GAS Type Fireplace InstallationInstalling Optional Blower Accessory Installing GA3700/DA3610T BlowersSide View Installation Items Needed Installing GAS Piping to Fireplace LocationConnecting Fireplace to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Pressure Testing Fireplace Gas Connections Installing Optional Wall Mount Switch GWMS2REMOVING/REPLACING Glass Door Installing Remote ReceiverInstalling Left Side Brick Panel Installing Optional Brick Liner D8037AInstalling Log No Installing LOGS, Lava Rock and Glowing EmbersLighting Instructions For Your Safety Read Before LightingManual Lighting Procedure Operating FireplaceOptional Remote Operation Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersCleaning and Maintenance Observed Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Service Hints Replacement PartsWiring Diagram Technical ServiceBDV34NA BDV34PA SpecificationsAccessories Brass Louver KIT Receiver and HAND-HELD Remote Control KIT Ghrc SeriesDuplex Outlet KIT Manual Blower KIT GA3700BDV34NA7 BDV34PA Illustrated PARTS37 BreakdownDIRECT-VENT Fireplace BDV34NA BDV34PA Parts ListWarranty Information