Desa BDV34PA, BDV34NA installation manual Installing Optional Wall Mount Switch GWMS2

Page 20

®BDV34NA AND BDV34PA

DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)

FIREPLACE INSTALLATION

Continued

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.

Close manual shutoff valve (see Fig-

 

ure 37).

2.

Pressurize supply piping system by ei-

 

ther opening propane/LP supply tank

 

valve for propane/LP gas fireplace or

 

opening main gas valve located on or near

 

gas meter for natural gas fireplace, or

 

using compressed air.

3.

Check all joints from propane/LP sup-

 

ply tank or gas meter to manual shutoff

INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2

1.Connect one terminal of 25 ft. wire for the wall switch to the TPTH terminal on the valve. Connect remaining wire terminal to the TH terminal on the valve. Make sure that the wire termi- nals are in the positions on the unit as pictured in Figure 41, page 21. If wires are not connected as shown the switch will not work.

2.Route the 25 ft. wire through openings provided on the sides of the fireplace to a convenient location to mount your switch.

3.Connect one bare wire end to each of the terminals of the GWMS2 wall switch.

4.Install the wall switch and cover in the wall.

valve (see Figure 38 for propane/LP or

Figure 39 for natural). Apply commer-

cial leak test solution to all gas joints.

Bubbles forming show a leak. Correct

all leaks at once.

Pressure Testing Fireplace Gas Connections

1.Open manual shutoff valve (see Fig- ure 37).

2.Open propane/LP supply tank valve for propane/LP fireplace or main gas valve located on or near gas meter for natu- ral gas fireplace.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from manual shutoff valve to thermostat gas valve (see Fig- ure 38 for propane/LP or Figure 39 for natural). Apply commercial leak test so- lution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

5.Light fireplace (see Operating Fire- place, pages 24 and 25). Check all other internal joints for leaks.

6.Turn off fireplace (see To Turn Off Gas to Appliance, page 24).

Open

Manual

Shutoff

Valve

Closed

Figure 37 - Manual Shutoff Valve

Propane/LP Supply

Tank

Manual

Shutoff Valve

Gas Valve

Figure 38 - Checking Gas Joints for Propane/LP Gas Fireplace

Manual

Shutoff Valve

Gas Meter

Gas Valve

Figure 39 - Checking Gas Joints for Natural Gas Fireplace

20

105980

Image 20
Contents Natural GAS Model BDV34NA PROPANE/LP GAS Model BDV34PA For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information BDV34NA and BDV34PAProduct Features Product IdentificationGlossary Terms Local CodesPRE-INSTALLATION Preparation Location and Space RequirementsClearances Framing and FinishingPRE-INSTALLATION Preparation General Venting Location of Vent TerminationGeneral Venting Venting Installation Installation PrecautionsInstallation Planning Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Horizontal VentingVenting with Two 90 Elbows Cathedral Ceiling Installation Installation for Vertical TerminationFlat Ceiling Installation Vertical Termination Configurations Venting with One 90 ElbowVertical Venting High Altitude Installation Parts Lists for Venting Kits and ComponentsVanguard Rigid Venting Vanguard Flexible VentingFireplace Installation Installing Optional Blower AccessoryInstalling GA3700/DA3610T Blowers Check GAS TypeSide View Installing GAS Piping to Fireplace Location Installation Items NeededChecking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Installing Optional Wall Mount Switch GWMS2 Pressure Testing Fireplace Gas ConnectionsInstalling Remote Receiver REMOVING/REPLACING Glass DoorInstalling Optional Brick Liner D8037A Installing Left Side Brick PanelInstalling LOGS, Lava Rock and Glowing Embers Installing Log NoFor Your Safety Read Before Lighting Manual Lighting ProcedureOperating Fireplace Lighting InstructionsOperating Optional Blower Accessory Pilot AssemblyInspecting Burners Optional Remote OperationCleaning and Maintenance Troubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Replacement Parts Wiring DiagramTechnical Service Service HintsSpecifications BDV34NA BDV34PAAccessories Receiver and HAND-HELD Remote Control KIT Ghrc Series Duplex Outlet KITManual Blower KIT GA3700 Brass Louver KITIllustrated PARTS37 Breakdown BDV34NA7 BDV34PAParts List DIRECT-VENT Fireplace BDV34NA BDV34PAWarranty Information