Desa CGFP28P and CGFP28PT, Unvented Propane/Lp Gas Fireplace, Installation, Continued

Page 16
Test Pressures Equal To or Less Than 1/2 PSIG

Pressure Testing Fireplace Gas ConnectionsManual backgroundManual background CGFP28P and CGFP28PT

UNVENTED PROPANE/LP GAS FIREPLACE

INSTALLATION

Continued

Test Pressures Equal To or Less Than 1/2 PSIG

1.Close manual shutoff valve (see Fig- ure 34).

2.Pressurize supply piping system by ei- ther using compressed air or opening propane supply tank valve.

3.Check all joints from propane supply tank to manual shutoff valve (see Fig- ure 35). Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

4.Correct all leaks at once.

Pressure Testing Fireplace Gas Connections

1.Open manual shutoff valve (see Fig- ure 34).

2.Open propane supply tank valve.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from manual shutoff valve to thermostat gas valve (see Fig- ure 35). Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

5.Correct all leaks at once.

6.Light fireplace (see Operating Fire- place, pages 18 and 19 [Thermostat- controlled models] or pages 19 and 20 [Manually-controlled models]). Check all other internal joints for leaks.

7.Turn off fireplace (see To Turn Off Gas to Appliance, page 18, [Thermostat- controlled models] or page 20 [Manu- ally-controlled models]).

Open

Manual Manual background

Shutoff

Valve

Closed

Manual Shutoff Valve

Propane

Supply

Tank

Manual Gas Valve

Figure 35 - Checking Gas Joints

Figure 34 - Manual Shutoff Valve

16

103414

Image 16
Contents OWNER’S OPERATION AND INSTALLATION MANUAL CGFP28P AND CGFP28PTWHAT TO DO IF YOU SMELL GAS Do not try to light any applianceSAFETY INFORMATION CGFP28P and CGFP28PTUNVENTED PROPANE/LP GAS FIREPLACE WARNINGSLOCAL CODES PRODUCT IDENTIFICATIONUNPACKING PRODUCT FEATURES SAFETY FEATURESAIR FOR COMBUSTION AND VENTILATION OPERATIONDETERMINING FRESH-AIRFLOW FOR FIREPLACE LOCATION ContinuedAIR FOR COMBUSTION AND VENTILATION VENTILATION AIR CGFP28P and CGFP28PTUNVENTED PROPANE/LP GAS FIREPLACE AIR FOR COMBUSTION AND VENTILATIONELECTRICAL HOOKUP When Using Optional Blower INSTALLATIONCHECK GAS TYPE INSTALLING GA3650T BLOWER ACCESSORY INSTALLATIONCGFP28P and CGFP28PT UNVENTED PROPANE/LP GAS FIREPLACEOPERATING THE BLOWER INSTALLATIONIf your fireplace system is installed ContinuedINSTALLATION INSTALLING GA3650T BLOWER ACCESSORYCGFP28P and CGFP28PT UNVENTED PROPANE/LP GAS FIREPLACEINSTALLATION a. If your fireplace system is installedContinued Operating the BlowerINSTALLATION CLEARANCES CONVENTIONAL FIREPLACE INSTALLATIONINSTALLATION CGFP28P and CGFP28PTBUILT-INFIREPLACE INSTALLATION Check Local Building CodesINSTALLATION ContinuedINSTALLING GAS PIPING TO FIREPLACE LOCATION INSTALLATIONCGFP28P and CGFP28PT UNVENTED PROPANE/LP GAS FIREPLACECHECKING GAS CONNECTIONS Pressure Testing Gas Supply Piping SystemINSTALLATION Pressure Testing Fireplace Gas ConnectionsCGFP28P and CGFP28PT UNVENTED PROPANE/LP GAS FIREPLACEINSTALLATION INSTALLING LOGSContinued FOR YOUR SAFETY READ BEFORE LIGHTING OPERATING FIREPLACELIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCEMANUAL LIGHTING PROCEDURE THERMOSTAT CONTROL OPERATIONFOR YOUR SAFETY READ BEFORE LIGHTING OPERATING FIREPLACEINSPECTING BURNERS VARIABLE MANUAL CONTROL OPERATIONPILOT FLAME PATTERN FRONT BURNER FLAME PATTERNCLEANING AND MAINTENANCE LOGSTROUBLESHOOTING OBSERVED PROBLEMCGFP28P and CGFP28PT UNVENTED PROPANE/LP GAS FIREPLACETROUBLESHOOTING Maintenance, pageContinued Refer to Air for Combustion and VentiTROUBLESHOOTING CGFP28P and CGFP28PTUNVENTED PROPANE/LP GAS FIREPLACE ContinuedSERVICE HINTS SPECIFICATIONSTECHNICAL SERVICE PARTS CENTRALSILLUSTRATED PARTS BREAKDOWN CGFP28PCGFP28P and CGFP28PT UNVENTED PROPANE/LP GAS FIREPLACEPARTS LIST CGFP28PPART NUMBER DESCRIPTIONLOG BASE ASSEMBLY ILLUSTRATEDPARTS BREAKDOWNCGFP28PT LOG BASE ASSEMBLY THERMOSTAT- CONTROLLED MODELPARTS LIST FIREPLACE CGFP28P and CGFP28PTUNVENTED PROPANE/LP GAS FIREPLACE ILLUSTRATEDFIREPLACE CGFP28P CGFP28PT PARTS LISTREPLACEMENT PARTS ACCESSORIESPARTS UNDER WARRANTY PARTS NOT UNDER WARRANTYPage WARRANTY INFORMATION NOT A UPCModel Serial No Date Purchased 2701 Industrial Drive P.O. Box Bowling Green, KY