Sub Section [82]-[85] Wireless Zone Supervision (Zones 1 - 32)

Programming these sections determines whether or not the zone transmitter will be supervised.

Panic Pendants do not send Supervisory signals and cannot be supervised.

Sub Section [90] General Wireless Options (Zones 1 - 32)

Option Description

[1]-[6] Future Use

[7]ON: RF Jam Disabled.RF Jam is disabled. OFF: RF Jam Enabled. RF Jam is enabled.

[8]ON: Global Placement Test All placements (zones) tested. OFF: Individual Module Placement Test. Installer must enter zone number for placement test.

Section [898]: Wireless Device Enrollment - See Section 2 of this manual.

Section [899]: Template Programming - See Section 3 of this manual.

Section [900]: Panel Version Displayed

Section [900]: Display Panel Version. The system will display the version of the control panel (for example, [0100] indicates panel version 1.00).

Section [904]: Wireless Module Placement Test

Enter Section [904] followed by the 2-digit number of the wireless zone to test. When a wireless signal is received from the selected transmitter, the system will indicate the location as Good or Bad as follows:

Good: One bell squawk, keypad displays ‘GOOD’

Bad: Three bell squawks, keypad displays ‘BAD’

Press [#] to exit when testing is complete. Enter the 2-digit zone number for the next wireless device to test or press [#] to return to standard pro- gramming.

Section [990] Installer Lockout Enable

Enter Section [990][Installer Code][990] to enable the Installer Lockout feature. A hardware default cannot be performed when the Installer Lockout feature is ON. In addition, the system will chatter the line seizure relay 10 times if the panel is powered up to indicate the feature is ON.

Section [991] Installer Lockout Disable

Enter Section [991][Installer Code][991] to turn the Installer Lockout feature OFF.

Section [996] Restore Wireless Device Default Programming

Enter Section [996][Installer Code][996] to return wireless programming to factory defaults.

Section [998] Restore Control Panel Default Programming

Enter Section [998][Installer Code][998] to return control panel programming to factory defaults.

Wireless device programming and keypad programming are not defaulted

To default Labels see Section [996] Label Reset in Keypad Programming

To default Wireless Devices see Section [996] above

Section [999] Restore System Default Programming

Enter Section [999][Installer Code][999] to return system programming to factory defaults.

Except for Labels, All programming including wireless device programming and keypad programming will be returned to factory defaults. To default Labels see Section [996] Label Reset in Keypad Programming

Hardware Reset (Default) Main Control Panel

Perform the following to default the main control panel:

Power down the system completely.

Connect a short between I/O 1 and I/O 2 on the control panel (remove all other wires from these terminals).

Power up the control panel (AC power only) for 10 full seconds.

Power down the control panel, remove short between I/O 1 and I/O 2.

Power up the control panel.