DSCover Satellite Products SCW904x Third Keypad Options, Programmed LCD Message, Label Reset

Models: SCW904x

1 64
Download 64 pages 52.09 Kb
Page 51
Image 51
Section [076] Third Keypad Options

Section 8: Programming Descriptions

Section [076] Third Keypad Options

Option Description

[1]ON: Chime Enabled for Zone Openings. When the zone is open and the chime feature is enabled ([*][4] Door Chime), the keypad

will chime the selected chime tone for the zone. OFF: Chime Disabled for Zone Openings. The keypad will not chime for zone openings

[2]ON: Chime Enabled for Zone Closings. When the zone is closed and the chime feature is enabled ([*][4] Door Chime), the keypad

will chime the selected chime tone for the zone. OFF: Chime Disabled for Zone Closing. The keypad will not chime for zone clos- ings

[3-8]Future Use

Section [077] Programmed LCD Message

Enter a 32 character message. If there is any thing other than blanks programmed into this section, the keypad will time out to this message instead of the Time and Date display. Any option or feature that overrides the clock display will also override the LCD message. An override by the system will not be counted against the Message Duration programmed in Section [078]. This message can be programmed in Installers Pro- gramming or using DLS.

Section [078] Programmed LCD Message Duration

Enter a 3 digit number. Valid Entries are 001 to 255 seconds. 000 = Unlimited Duration.

This section is used to program the number of times an LCD message must be cleared from the LCD displays (by pressing any key) before it will no longer be displayed. When programmed on the system, the LCD keypad will display the message when not in use. Programming 000 in this section will result in the message never clearing. This could be used as a greeting (residential) or a company message (commercial). This over- rides the settings of Clock Display options in Section [075].

Section [201]-[234] Door Chime Options for Zones 1-34

Option Description

[1]ON: 6 Beeps. Standard Door Chime Enabled.OFF: Disabled. Standard Door Chime Disabled.

[2]ON: Bing Bing Sound. OFF: Disabled

[3]ON: Ding Dong Sound. OFF: Disabled

[3]ON: Alarm Tone. The keypad will sound a medium volume alarm signal for 4 seconds. OFF: Disabled [5-8]Future Use

Enable one Door Chime option for each zone. If more than one option is enabled, the last numerical option enabled will take pre- cedence. For example, if options 3 and 1 are both enabled, then the zone will sound ‘Ding-Dong’. If all Door Chime options are disabled, the keypad will not sound a Door Chime tone for that particular zone.

Section [996] Label Reset

Resets Programmable Labels to Factory Defaults. Entering this section and pressing [*] returns all programmable system labels to the default con- ditions. This does not affect any of the keypad configuration sections.

WWW.DIYALARMFORUM.COM47

Page 51
Image 51
DSCover Satellite Products SCW904x manual Third Keypad Options, Programmed LCD Message Duration, Label Reset