Self Contained Wireless Alarm System v1.0
Section [170] PGM Output Timer
Program the time, in seconds, PGM outputs programmed to follow the PGM Output Timer will activate for. Valid entries are [001] to [255].
Section [176] Cross Zone/Police Code Timer
Program the time, in seconds (Cross Zone) or minutes (Police Code), that the panel will use to determine if a Cross Zone or Police Code event has occurred. If data [000] is programmed when using the Police Code feature, the panel will generate a Police Code event if any two zones go into alarm during any
Section [190] No Activity Arming Pre-Alert Duration
Program the time, in minutes, for the No Activity Arming
Section [191] No Activity Arm Timer
Program the time, in minutes, for the No Activity Arm Timer. If Delay Zones are restored and no zone activity is detected for the time pro- grammed, the system will start the auto arm sequence. Valid entries are [000] to [255].
Section [202]-[206] Zone Assignments
Activates the selected zones. Zones
If a zone assignment is set, but no serial number is enrolled (zones 1 to 32), or the terminals are set as PGM outputs instead of zone inputs (zones 33 and 34), then these zones will appear in the bypass list.
Section [301]-[303] Communication Telephone Numbers
Program the phone numbers as required. Phone Number 3 is dedicated as a
HEX [A] | Not used |
HEX [B] | Simulates a [ ] key press |
HEX [C] | Simulates a [#] key press |
HEX [D] | Additional dial tone search |
HEX [E] | |
HEX [F] | End of phone number marker |
Section [304] Call Waiting Cancel String
Program the digits required to disable call waiting. If enabled, the system will dial the programmed string on the first dialing attempt. Program unused digits with data [F]. This section is activated in Section [382] Opt [4].
Section [310] System Account Number
Program the System Account Number. Only the SIA format supports
Section [320]-[348] Reporting Codes
Program the reporting code for all events to be transmitted. For description of when each reporting event will be transmitted, refer to
Appendix A – Reporting Codes. The panel also supports Automatic SIA and Automatic Contact ID reporting. Program data [00] to disable the reporting of an event. If any other data is programmed (Data [01] to [FF]) the panel will automatically generate the correct reporting event when transmitting to the central station. For all formats excluding Automatic SIA and Automatic Contact ID, the panel will not attempt to report an event if data [00] or data [FF] is programmed for the reporting code.
Section [350] Communicator Format
Program the
Section [351]-[376] Communicator Call Direction Options
Reporting events are categorized into 5 groups; Alarm/Restoral, Opening/Closing, Tamper Alarm/Restoral, System Maintenance and Test Trans- missions. Program which Phone Number the control panel will use to transmit reporting events by turning the option ON in the correct Section. Phone Number 1 and/or Phone Number 2 can be used.