DSCover Satellite Products SCW904x manual Programming Worksheets, Zone Loop Response Options

Models: SCW904x

1 64
Download 64 pages 52.09 Kb
Page 23
Image 23
[030] Zone Loop Response Options

7.2 Programming Worksheets

[030] Zone Loop Response Options

Opt

Def. ON

OFF

1

Zone 33 is Fast Loop Response

Zone 33 is Normal Loop Response

2

Zone 34 is Fast Loop Response

Zone 34 is Normal Loop Response

3-8

Future Use

 

[101]-[134] Zone Attributes (Options 10-13 are reserved for Future Use).

Zone Attribute Defaults

 

Attribute:

1

2

3

4

5

6

7

8

9

14

15

16

 

ON

Audible Steady Chime Bypass Force* Swing

Tx. Delay

Cross Zn

2-way Audio

NC

SEOL

DEOL

 

OFF

Silent

Pulsed

No

No

No

No

No

No

No

Loops

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone Type:

 

 

 

 

 

 

 

 

 

 

 

 

00

Null Zone

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

01

Delay 1

ON

ON

ON

ON

OFF

ON

OFF

OFF

ON

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02

Delay 2

ON

ON

ON

ON

OFF

ON

OFF

OFF

ON

OFF

ON

OFF

03

Instant

ON

ON

ON

ON

OFF

ON

OFF

OFF

ON

OFF

ON

OFF

04

Interior

ON

ON

OFF

ON

OFF

ON

OFF

OFF

ON

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

05

Interior Stay/Away

ON

ON

OFF

ON

ON

ON

OFF

OFF

ON

OFF

ON

OFF

06

Delayed Stay/Away

ON

ON

OFF

ON

ON

ON

OFF

OFF

ON

OFF

ON

OFF

07

Future Use

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

08

Future Use

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

09

24hr Superv. (Hardwired)

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

ON

OFF

10

24hr Superv. Buzzer

OFF

ON

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

24hr Burglary

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

ON

OFF

12

Future Use

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

13

24hr Gas

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

24hr Heat

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

15

24hr Medical

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

ON

OFF

16

24hr Panic

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

24hr Emergency

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

ON

OFF

18

Future Use

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

19

24hr Water

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

24hr Freeze

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

ON

OFF

21

Future Use

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

22 Momentary Keyswitch Arm

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

23 Maintained Keyswitch (Hardwired)

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

ON

OFF

24

Future Use

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

25

Interior Delay

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26

24hr Non-alarm

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

ON

OFF

27-31 Future Use

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

32

Instant Stay/Away

ON

ON

OFF

ON

OFF

ON

OFF

OFF

ON

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

33

Future Use

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

34

Future Use

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

35

Future Use

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36

24hr Non-latching Tamper

OFF

ON

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

37 Night Zone

ON

ON

OFF

ON

ON

ON

OFF

OFF

ON

OFF

ON

OFF

87

Delay 24hr Fire (Wireless)

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

88

Stand. 24hr Fire (Wireless)

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

89

Auto-verified Fire (Wireless)

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

* For UL installations, do not change attribute 5 (Force Arming) from the default setting.

For CP-01 installations:

Option 6 (Swinger) is defaulted ON for zone definitions 09-11, 13-17, 19,20

Option 7 (Tx Delay) is defaulted ON for zone definitions 01-06, 09-11, 13-17, 19,20,25,32,36,37

WWW.DIYALARMFORUM.COM19

Page 23
Image 23
DSCover Satellite Products SCW904x manual Programming Worksheets, Zone Loop Response Options