Self Contained Wireless Alarm System v1.0
7.2 Programming Worksheets
Unless indicated otherwise, default values apply to NA, EU and
EU Defaults are indicated by a Superscript EU e.g., ( NA Defaults are indicated by a Superscript NA e.g., (
EU
NA
) or ( EU005) ) or ((NA005)
Keypad and Function Key Programming
See “Local Keypad Programming” on page 30. for additional options.
[000]Function Key Programming
[1]Function Key 1 Assignment
[2]Function Key 2 Assignment
[3]Function Key 3 Assignment
[4]Function Key 4 Assignment
[5]Function Key 5 Assignment
Function Key Options:
00 | Null Key | 09 | Future Use | *27 | Disarm | ||
01 | Future Use | 10 | Future use | *29 | [A]uxilliary Alarm | ||
02 | Future Use | 11 | Future use | *30 | [P]anic | ||
03 | Stay Arm | 12 | Future Use |
|
| ||
04 | Away Arm | 13 | [ | ][7][1] Command Output #1 | * Applies to Key Fobs only | ||
05 | [ | ][9] No Entry Arm | 14 | [ | ][7][2] Command Output #2 | See Section [804] Subsection | |
06 | [ | ][4] Chime On / Off | 15 | For Future Use |
|
| |
07 | Future Use | 16 | [ | ][0] Quick Exit |
|
| |
08 | [ | ][1] Bypass Mode | 17 | [ | ][1] Reactivate Stay/Away Zones |
|
|
Key 1
Key 2
Key 3
Key 4
Key 5
Keypad Defaults
03 ___
04 ___
06 ___
08 ___
16 ___
[001]-[002] Zone Definitions
00 | Null Zone (Not Used) |
|
|
| 13 | 24 | Hour Gas* |
|
|
|
|
| 25 | Interior Delay* |
|
|
|
|
| ||||||
01 | Delay 1* |
|
|
|
|
| 14 | 24 | Hour Heat* |
|
|
|
|
| 26 | 24 Hour |
|
|
|
| |||||
02 | Delay 2* |
|
|
|
|
| 15 | 24 | Hour Medical* |
|
|
|
|
|
|
|
|
| |||||||
03 | Instant* |
|
|
|
|
| 16 | 24 | Hour Panic* |
|
|
|
|
| 32 | Instant Stay/Away* |
|
|
|
| |||||
04 | Interior* |
|
|
|
|
| 17 | 24 | Hour Emergency* |
|
|
|
|
|
|
|
| ||||||||
05 | Interior, Stay/Away* |
|
|
|
| 18 | Future Use |
|
|
|
|
|
| 36 | 24 Hr. |
|
|
| |||||||
06 | Delay, Stay/Away* |
|
|
|
| 19 | 24 | Hour Water* |
|
|
|
| 37 | Night Zone |
|
|
|
|
| ||||||
|
|
|
| 20 | 24 | Hour Freeze* |
|
|
|
| 87 | Delayed 24 Hr. Fire (Wireless)** |
|
|
| ||||||||||
09 | 24 Hour Supervisory (Hardwired) | 21 | Future Use |
|
|
|
|
|
| 88 | Standard 24 Hr. Fire (Wireless)** |
|
|
| |||||||||||
10 | 24 Hour Supervisory Buzzer* |
| 22 | Momentary Keyswitch Arm* |
|
| 89 |
|
| ||||||||||||||||
11 | 24 Hour Burglary* |
|
|
|
| 23 | Maintained Keyswitch Arm (Hardwired)* |
|
|
|
|
|
|
|
|
|
| ||||||||
12 | Future Use |
|
|
|
|
| 24 | Future Use |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
*For burglary applications only |
|
| ** For residential fire applications only |
|
|
|
|
|
|
|
|
|
| ||||||||||||
Section | Zone | Default |
|
|
| Section | Zone | Default |
|
|
| Section | Zone | Default |
|
|
| Section | Zone | Default |
|
|
| ||
[001] | 01 | 01 | I | I | I | [001] | 09 |
| 00 | I | I | I | [002] | 17 | 00 | I | I | I | [002] | 25 | 00 | I | I | I | |
|
| 02 | 03 | I | I | I |
| 10 |
| 00 | I | I | I |
| 18 | 00 | I | I | I |
| 26 | 00 | I | I | I |
|
| 03 | 03 | I | I | I |
| 11 |
| 00 | I | I | I |
| 19 | 00 | I | I | I |
| 27 | 00 | I | I | I |
|
| 04 | 03 | I | I | I |
| 12 |
| 00 | I | I | I |
| 20 | 00 | I | I | I |
| 28 | 00 | I | I | I |
|
| 05 | 04 | I | I | I |
| 13 |
| 00 | I | I | I |
| 21 | 00 | I | I | I |
| 29 | 00 | I | I | I |
|
| 06 | 04 | I | I | I |
| 14 |
| 00 | I | I | I |
| 22 | 00 | I | I | I |
| 30 | 00 | I | I | I |
|
| 07 | 04 | I | I | I |
| 15 |
| 00 | I | I | I |
| 23 | 00 | I | I | I |
| 31 | 00 | I | I | I |
|
| 08 | 04 | I | I | I |
| 16 |
| 00 | I | I | I |
| 24 | 00 | I | I | I |
| 32 | 00 | I | I | I |
16WWW.DIYALARMFORUM.COM