Self Contained Wireless Alarm System v1.0
[37] | Night Zone: Functions like Interior Stay/Away (05) but will remain bypassed if the user presses [ ][1] to |
| zones when armed in the Stay mode |
[87]Delayed
[88]Standard
[89]
Section [005] System Times
After entering Section [005], program the Entry Delay 1, Entry Delay 2 and Exit Delay for the system. Entries are in seconds. Program the Bell
Section [006] Installer Code
The default Installer Code is [5555] or [555555] if
Section [007] Master Code
The default Master Code is [1234] or [123456] if
Section [009] I/O Programming (Zones/PGMs)
The alarm system has two
PGM Output Options:
Option Description
[00]Null PGM: Not Used
[01]Residential Fire and Burglary: Output will activate (steady for burglary, pulsing for fire) if an alarm occurs.
[05]System Armed Status: Output will activate when the system is armed
[06]Ready to Arm: Output will activate when system is in the Ready state (Ready light ON)
[07]Keypad Buzzer Follows Output: Activates when the keypad buzzer is activated for 24 hour Supervisory, Zone Alarms, Entry Delay, Audible Exit Delay, No Activity Arming
[08]Courtesy Pulse: Output will activate during entry/exit delay when the system is armed – will remain active for an additional 2 minutes after the entry or exit delay expires
[09]System Trouble Output (with trouble options): Output will activate when any selected trouble condition is present.
[10]System Event Output (with trouble options): Output will activate when any selected condition occurs. Output can be programmed to follow timer.
[11]System Tamper: Output will activate when any tamper condition is present (i.e., zones)
[12]TLM and Alarm: Output will activate if a telephone line trouble is present and then an alarm occurs
[17]Away Armed Status: Activates when the system is armed in Away mode
[18]Stay Armed Status: Activates when system is armed in Stay mode
[19] | Command Output 1:Activates when a [ ][7][1] command is entered on the keypad – Command can be programmed to require a |
| valid access code and output can be programmed to activate for the time programmed in Section [170] or programmed to latch. |
[20] | Command Output 2: Activates when a [ ][7][2] command is entered on the keypad – Command can be programmed to require |
| a valid access code and output can be programmed to activate for the time programmed in Section [170] or programmed to latch. |
Section [012] Keypad Lockout
The system can be programmed to ‘lockout’ the keypad if a series of incorrect user or installer codes are entered. When lockout is active, the sys- tem will emit a steady
34WWW.DIYALARMFORUM.COM