DSCover Satellite Products SCW904x manual Installation & Wiring, Technical Summary, Specifications

Models: SCW904x

1 64
Download 64 pages 52.09 Kb
Page 5
Image 5
Section 1: Installation & Wiring

Section 1: Installation & Wiring

Section 1: Installation & Wiring

This Installation Guide provides the basic installation, wiring and programming information for the PowerSeries Self Contained Wireless (SCW) Security System.

This publication covers the following versions of the SCW Security System:

SCW9045-433 v1.0

SCW9045-868 v1.0

SCW9047-433 v1.0

SCW9047-868 v1.0

 

These models are not UL/ULC Listed (intended for European market only)

TECHNICAL SUMMARY

 

Specifications

 

Temp Range

0°C-49°C (32°F-120°F)

Humidity (Max)

93%RH Non Condensing.

Power Supply

16.5VAC/20VA @50/60Hz.

Current Draw from Transformer

400mA AC (Max.)

Aux+ Output

12.0-12.5VDC/100mA

Features

 

Wireless Zones

32

*On-board I/O

2

Partitions

1

Wireless Keys

16

User Codes

16 + 1 Master Code

Event Buffer

128 Events

LCD Display

2 Rows x 16 Char

Plug-in Transformer

Secondary 16.5 VAC/20-40VA

Battery Backup

7.2VDC@1500 mAH

(24Hr Backup)

 

*I/O Terminals can be configured as Zone Inputs or PGM Outputs When configured as PGMs, outputs are 50mA

Compatible Wireless Devices

SCW9045-433 v1.0

all DSC 433 or 433EU Devices

SCW9047-433 v1.0

all DSC 433 or 433EU Devices

SCW9045-868 v1.0

all DSC 868 Devices

SCW9047-868 v1.0

all DSC 868 Devices

UL Listed Wireless Devices

WS4904(P)

PIR Motion Detector

WS4916

Smoke Detector

WS4945

Door Contact

WS4965

Door Contact

WLS912L-433

Glass Break Detector

WLS914-433

PIR Motion Detector

WS4938

Panic Pendant

WS4939

Wireless Key

Classified in Accordance with ANSI/SIA CP-01-2000 (SIA-FAR)

IMPORTANT NOTE!

This equipment, SCW Alarm System shall be installed and used within an environment that provides the pollution degree max 2 and over-voltages category II NON-HAZARDOUS LOCATIONS, indoor only. The equipment is DIRECT PLUG-IN connected and is designed to be installed, serviced and/or repaired by service persons only; [service person is defined as a person having the appropriate technical training and experience necessary to be aware of hazards to which that person may be exposed in performing a task and of measures to minimize the risks to that person or other persons]. There are no parts replaceable by the end-user within this equipment.

The power supply must be direct plug-in,fail safe, with dou- ble or reinforced insulation between primary and secondary circuits. In EU countries it must meet the applicable require- ments of the Low Voltage Directive and protected as per the EN60950-1:2001 Standard Requirements. In all other countries, it must be of an approved type acceptable to the local authori- ties; it is the installer’s responsibility to ensure that the socket- outlet that the transformer is plugged-in, is near the equipment and is easily accessible.

The wiring (cables) used for installation of the SCW Alarm Sys- tem and accessories, shall be insulated with PVC, TFE, PTFE, FEP, Neoprene or Polyamide.

(a)The equipment enclosure must be secured to the building structure before operation.

(b)Internal wiring must be routed in a manner that prevents:

-Excessive strain on wire and on terminal connections;

-Loosening of terminal; connections;

-Damage of conductor insulation

(c)Disposal of the used battery packs shall be made according to the waste recovery and recycling regulations applicable to the intended market.

(d)Before servicing, DISCONNECT the power and telephone connection.

(e)Do NOT route any wiring over circuit boards.

WWW.DIYALARMFORUM.COM1

Page 5
Image 5
DSCover Satellite Products SCW904x manual Installation & Wiring, Technical Summary, Specifications, Features