DSCover Satellite Products SCW904x Programming Descriptions, Keypad Function Key Programming

Models: SCW904x

1 64
Download 64 pages 52.09 Kb
Page 37
Image 37
Section 8: Programming Descriptions

Section 8: Programming Descriptions

Section 8: Programming Descriptions

The following is a brief description of the features and options available in the control panel.

Section [000] Keypad Function Key Programming

The five function keys can be reprogrammed with following functions. See Keypad Function Key Programming on page 16 for defaults

Option

Description

 

Option

Description

[00]

Null Key: Program non functioning keys with this option

[14]

Command Output #2: See [ ][7][1] on page 13

[03]

Stay Arm: See Stay Arm on page 11

[16]

Quick Exit: See [ ][0] on page 13

[04]

Away Arm: See Away Arm on page 11

[17]

Reactivate Stay/Away Zones: See [ ][1] on page 11

[05]

No Entry Arm: See [

][9] on page 13

*[27]

Disarm: See Disarm on page 11

[06]

Chime On/Off: See [

][4] on page 12

*[29]

[A]ux Alarm: Same as [A] key

[08]

Bypass: See [ ][1] on page 11

*[30]

[P]anic: Same as [P] key.

[13]

Command Output #1: See [ ][7][1] on page 13

*Applies to Key Fobs only (See Section [804] Subsection [61]-[76]

Section [001]-[002] Zone Definitions

Option Description

[00]Null Zone: Zone not used

[01]Delay 1: When armed, provides entry delay when violated (follows Entry Delay 1)

[02]Delay 2: When armed, provides entry delay when violated (follows Entry Delay 2)

[03]Instant: When armed, instant alarm when violated

[04]Interior: When armed, instant alarm if the zone is violated first, will follow entry delay if entry delay is active

[05]Interior Stay/Away: Similar to ‘Interior’ except panel will auto-bypass the zone if armed in the Stay mode

[06]Delay Stay/Away: Similar to ‘Delay 1’ except panel will auto-bypass the zone if armed in the Stay mode

[07]-[08]

Future Use

[09]24-Hour Supervisory (Hardwired): Instant Alarm, silent at default.

[10]24-Hour Supervisory Buzzer: Instant alarm, panel will activate keypad buzzer instead of bell output

[11]24-Hour Burglary: Instant alarm when violated, audible alarm at default.

[12]Future Use

[13]24-Hour Gas: Instant alarm when violated, audible alarm at default.

[14]24-Hour Heat: Instant alarm when violated, audible alarm at default (also known as high-temp).

[15]24-Hour Medical: Instant alarm when violated, audible alarm at default.

[16]24-Hour Panic: Instant alarm when violated, audible alarm at default.

[17]24-Hour Emergency: Instant alarm when violated, audible alarm at default.

[18]Future Use

[19]24-Hour Water: Instant alarm when violated, audible alarm at default (also known as flood).

[20]24-Hour Freeze: Instant alarm when violated, audible alarm at default (also known as low-temp).

[21]Future Use

[22]Momentary Keyswitch Arm: Arms or disarms the system when violated

[23]Maintained Keyswitch Arm: Arms system when violated, disarms system when restored

[24]For Future Use

[25]Interior/Delay: Function as an Interior zone when armed in Away mode, and as a Delay zone when armed in the Stay mode

[26]24-HourNon-Alarm:Zone will NOT create an alarm. Can be used with chime to identify a specific event.

[27]-[31]

Future Use:

[32]Instant Stay/Away: Similar to ‘Instant’ except panel will auto-bypass the zone if armed in the Stay mode

[33]-[35]

Future Use

[36]24-HourNon-Latching Tamper: Instant tamper condition when violated. Active in armed and disarmed state.

WWW.DIYALARMFORUM.COM33

Page 37
Image 37
DSCover Satellite Products SCW904x manual Programming Descriptions, Keypad Function Key Programming, 002Zone Definitions