DSCover Satellite Products SCW904x Appendix D SIA False Alarm Reduction, SIA Feature, Comments

Models: SCW904x

1 64
Download 64 pages 52.09 Kb
Page 60
Image 60
Appendix D: SIA False Alarm Reduction

Self Contained Wireless Alarm System v1.0

Appendix D: SIA False Alarm Reduction

SIA Feature

Comments
Range/Default
Require-
Programming Section

 

 

ment

 

 

 

 

Exit Time

Access to Entry and Exit delays and Bell Time Out for the system

Range:45- 255 seconds

Required

[005], 3rd entry

 

Default: 60 sec.

(programmable)

 

 

 

 

Progress Annunciation/

Enables audible exit beeps from the keypad for the duration of exit delay

Keypads may be disabled

Allowed

Disable - for Silent Exit

 

Default: Enabled

 

[014], Option 6 ON

 

 

 

 

 

 

 

Exit Time Restart

Enables the exit delay restart feature

Default: Enabled

Required

[014], Option 2 ON

 

 

 

 

 

 

 

Auto Stay Arm on

Function Key: Stay Arming. All Stay/Away type zones (05, 06) will be automatically

If no exit after full arm

Required

Unvacated Premises

bypassed

Default: Enabled

 

[001]-[002] Zone type 05, 06

 

 

 

 

 

 

 

Exit Time and Progress

System Times and Audible Exit beeps can be disabled when using the Key fob to arm

Default: Enabled

Allowed

Annunciation/Disable

away the system

 

 

or Remote Arming

 

 

 

[005] and [014] bit 6

 

 

 

 

 

 

 

Entry delay(s)

Access to Entry and Exit delays and Bell Time Out for the system

Range: 30 sec. to 4 min.

Required

[005], 1st and 2nd entry

Note: Combined Entry delay and Communications Delay (Abort Window) shall not

Default: 30 sees

(programmable)

 

exceed 60s

 

 

 

 

 

 

Abort Window

Access to zone attributes, i.e, swinger shutdown, transmission delay and cross zone.

May be disabled

Required

for Non-Fire zones

Individual zones attribute bit 6 (Transmission delay) is by default ON

by zone or zone type

 

[101]-[134] bit 6 ON

 

Default: Enabled

 

 

 

 

 

Abort Window - for

Access to the programmable delay before communicating alarms

Range: 15 - 45 sec.

Required

Non-Fire zones

Note: Combined Entry delay and Communications Delay (Abort Window) shall not

Default: 30 sees

(programmable)

[377], 4th entry

exceed 60s

 

 

 

 

 

 

Abort Annunciation

Enables the “Communication Cancelled” message display on keypad

Annunciate that no

Required

[382], Option 3 ON

 

alarm was transmitted

 

 

 

Default: Enabled

 

 

 

 

 

Cancel Annunciation

Access to the reporting code for Alarm Cancelled

Annunciate that a

Required

[328], 8th entry

 

Cancel was transmitted

 

 

 

Default: Enabled

 

 

 

 

 

Duress Feature

Do not derive code from an existing Master/User code (e.g., Master code is 1234, the

No 1+/- derivative of another

Allowed

[*][5] Master Code

duress code should not be 1233 or 1235)

user code. No duplicates with

 

Option 2 ON

 

other user codes

 

 

 

Default: disabled

 

 

 

 

 

Cross Zoning

This option enables Cross Zoning for entire system. Individual zones can be enabled

Programming required

Required

[016] Option 1

for Cross zoning via Zone attribute bit 8 in sections [101] - [134]

Default: Disabled

 

[101]-[134] bit 8 OFF

 

 

 

 

 

 

 

Cross Zone Timer

Access to the programmable Cross Zone timer

May program

Allowed

[176]

 

Range: 001-255 sec./min.

 

 

 

Default: 60 secs

 

 

 

 

 

Swinger Shutdown for Alarms

Access to the swinger shutdown limit for zone alarms

For all non-fire zones

Required

[377] 1st entry

 

shut down at 1 or 2 trips

(programmable)

 

 

Default: 1 Trip

 

 

 

 

 

Swinger Shutdown Enable

Access to zone attributes, i.e., swinger shutdown, transmission delay and cross zone.

For non-police

Allowed

[101] - [134] bit 6 ON

Individual zones attribute bit 6 (Swinger shutdown enabled) is by default ON

response zones

 

 

 

Default: Enabled

 

 

 

 

 

24-Hr. Auto_verified Fire

Access to 24-Hr. Auto_verified Fire (Wireless)

Activates If a restoral is Not

Required

(Wireless) Zone type [89]

 

received within the specified

 

 

 

time

 

 

 

Default: disabled

 

 

 

 

 

Call Waiting Cancel Dial String

Access to the dialing sequence used to disable call waiting

Dependant on user phone

Required

[304], [382], Option 4 OFF

 

line

 

 

 

Default: disabled

 

 

 

 

 

 

Testing

 

 

 

 

 

 

System Test:

The system activates all keypad sounders, bells or sirens for 2 seconds and all keypad lights turn on.

 

[*][6] Master Code, Option 4

Refer to the User Manual (part no. 29007326).

 

 

 

 

 

 

Walk Test Mode:

This mode is used to test each zone on the system for proper functionality.

 

 

[*][6] Opt 8

 

 

 

 

 

 

 

Alarm Communications

Enables Communication of zone alarms while Walk Test is active.

 

 

During Walk Test

 

 

 

[382] Option 2:

 

 

 

 

 

 

 

Walk Test End and Begin

Access to the reporting codes for Walk Test Begin and Walk Test End.

 

 

Reporting Codes

 

 

 

[348], 1st and 2nd Entries

 

 

 

56WWW.DIYALARMFORUM.COM

Page 60
Image 60
DSCover Satellite Products SCW904x Appendix D SIA False Alarm Reduction, Self Contained Wireless Alarm System, SIA Feature