DSCover Satellite Products SCW904x manual Self Contained Wireless Alarm System

Models: SCW904x

1 64
Download 64 pages 52.09 Kb
Page 28
Image 28
[377]Communication Variables

Self Contained Wireless Alarm System v1.0

[375] System Maintenance Communicator Call Directions

 

Option 1

Option 2

Option 3-8

Section

First Telephone

Second Telephone

Not Used

 

Number (Default ON)

Number (Default OFF)

(Default OFF)

 

 

 

 

 

 

 

[375]

I

I

I

I

I

I

 

 

 

 

 

 

[376] System Test Transmissions Communicator Call Directions

 

Option 1

Option 2

Option 3-8

Section

First Telephone

Second Telephone

Not Used

 

Number (Default ON)

Number (Default OFF)

(Default OFF)

 

 

 

 

 

 

 

[376]

I

I

I

I

I

I

 

 

 

 

 

 

[377]Communication Variables

Default

003 I

0__I__0__I

1__I

Swinger Shutdown (Alarms and Rest)

001-014

Transmissions

003 I

I

I

I

Swinger Shutdown (Tampers and Rest)

001-014

Transmissions, 000=disabled on Non CP-01 Systems

003 I

I

I

I

Swinger Shutdown (Maint. and Rest)

001-014

Transmissions, 000=disabled

000 I

0__I__3__I

0__I

Communication Delay

000-255 seconds

030 I

I

I

I

AC Failure Communication Delay

001-255 minutes/hours, 000=disabled

EU002 NA010 I

I

I

I

TLM Trouble Delay

003-255 seconds x3 (e.g.,003 = 9 seconds)

030 I

I

I

I

Test Transmission Cycle (land line)

001-255 days/hours††

000 I

I

I

I

Future Use

 

 

007 I

I

I

I

Zone Low Battery Transmission Delay

000-255 days

030 I

I

I

I

Delinquency Transmission Cycle

000-255 days/hours†††, 000=disabled

000 I

0__I__0__I

5__I

Communications Cancelled Window

000-255 minutes

Dependent on programming in section [382], option [6] ††Dependent on programming in section [023], option [4]

†††Dependent on programming in section [380], option [8].

For UL installations, the Entry Delay plus Communication Delay time must not exceed 60 seconds.

[378]Test Transmission Time of Day

Default

9999 I I I I I Valid entries are 0000-2359 (9999 to disable)

[380] First Communicator Options

Opt

Def. ON

OFF

1

Communications Enabled

Communications Disabled

2

Restorals on Bell Time-out

Restorals Follow Zones

3

Pulse Dialing

DTMF Dialing

4Future Use

5Future Use

6

Alternate Dial (1st & 3rd)

Call 1st Number, Backup to 3rd

7

Future Use

 

8

Delinquency Follows Zone Activity (Hours)

Delinquency Follows Arming (Days)

24WWW.DIYALARMFORUM.COM