Self Contained Wireless Alarm System v1.0
[375] System Maintenance Communicator Call Directions
| Option 1 | Option 2 | Option | |||
Section | First Telephone | Second Telephone | Not Used | |||
| Number (Default ON) | Number (Default OFF) | (Default OFF) | |||
|
|
|
|
|
|
|
[375] | I | I | I | I | I | I |
|
|
|
|
|
|
[376] System Test Transmissions Communicator Call Directions
| Option 1 | Option 2 | Option | |||
Section | First Telephone | Second Telephone | Not Used | |||
| Number (Default ON) | Number (Default OFF) | (Default OFF) | |||
|
|
|
|
|
|
|
[376] | I | I | I | I | I | I |
|
|
|
|
|
|
[377]Communication Variables
Default
003 I | 0__I__0__I | 1__I | Swinger Shutdown (Alarms and Rest) | Transmissions | ||
003 I | I | I | I | Swinger Shutdown (Tampers and Rest) | Transmissions, 000=disabled on Non | |
003 I | I | I | I | Swinger Shutdown (Maint. and Rest) | Transmissions, 000=disabled | |
000 I | 0__I__3__I | 0__I | Communication Delay | |||
030 I | I | I | I | AC Failure Communication Delay | ||
EU002 NA010 I | I | I | I | TLM Trouble Delay | ||
030 I | I | I | I | Test Transmission Cycle (land line) | ||
000 I | I | I | I | Future Use |
|
|
007 I | I | I | I | Zone Low Battery Transmission Delay | ||
030 I | I | I | I | Delinquency Transmission Cycle | ||
000 I | 0__I__0__I | 5__I | Communications Cancelled Window |
†Dependent on programming in section [382], option [6] ††Dependent on programming in section [023], option [4]
†††Dependent on programming in section [380], option [8].
For UL installations, the Entry Delay plus Communication Delay time must not exceed 60 seconds.
[378]Test Transmission Time of Day
Default
9999 I I I I I Valid entries are
[380] First Communicator Options
Opt | Def. ON | OFF |
1 | Communications Enabled | Communications Disabled |
2 | Restorals on Bell | Restorals Follow Zones |
3 | Pulse Dialing | DTMF Dialing |
4Future Use
5Future Use
6 | Alternate Dial (1st & 3rd) | Call 1st Number, Backup to 3rd |
7 | Future Use |
|
8 | Delinquency Follows Zone Activity (Hours) | Delinquency Follows Arming (Days) |
24WWW.DIYALARMFORUM.COM