Appendix E: 2-Way Audio Verification (SCW9047 only)

Appendix E: 2-Way Audio Verification (SCW9047 only)

The following information is intended for use by the Central Station Operator.

The SCW9047 Audio Verification provides Talk and Listen-in capability for audio verification of alarms. This allows the central station to communicate with the occupants through the microphone and speaker of the alarm system. The commands indicated below are a subset of the

SIA Audio Verification Standard (November 11, 1997)

The 2-way Audio Session

1.Zone Violation: A 2-way audio session begins with the violation of a zone that has zone attribute 9 enabled. By default the following do NOT initiate a 2-way session:

Fire Zones, zone 87, 88, 89 and the Fire Key

Supervisory zones, zones 9 and 10

24 Hr Freeze zone, zone 20

By default 1-way audio (Listen-in only) is initiated by the following:

Silent Panic events (Silent [P], Silent Panic zone)

Duress alarm

Silent zone alarm (Zone attribute 1 OFF)

NOTE: The Operator can NOT switch to Talk mode (Speaker is always OFF)

2.Communication to the Monitoring Station: When the appropriate Alarm is triggered one of the following reporting codes/actions is sent to the monitoring station.

Format

Reporting Code/Event

 

 

SIA

L90

 

 

Contact ID

606

 

 

BPS

Communicates the Event, then automatically enters into 2-way Audio mode

 

 

3.Alerting the Operator: When the reporting code is received by the monitoring station or a 2-way session is automatically initiated, a 2-way Initiation (Start) tone will be sounded to alert the operator. A high (1800 Hz) tone and a low (900 Hz) tone are used to generate the following Session Tones. Short tone duration is 100ms. Long tone duration is 1 second.:

2-way Initiation (Start) Tone:

3 Hi Tones (Short)

After the third short Hi tone has sounded, the system switches directly into Listen-in mode without

 

a keypress from the monitoring station.

 

 

Reminder Tones:

 

 

 

1 Hi Tone (Short)

1 Short Hi Tone indicates 20 seconds are left in the audio session

 

 

1 low Tone

1 Short Low Tone indicates 10 seconds are left in the audio session

 

 

Subsequent Alarm:

 

 

 

1 Hi Tone Long

1 long Hi Tone indicates a new alarm event if Section [023] Option 6 (New Alarms will not discon-

 

nect 2-way Audio) is enabled, alarms will be delayed. If disabled the audio session will terminate.

 

NOTE: Receiving a subsequent alarm event tone will not restart the 90 second session timer.

 

 

Subsequent Fire Event:

 

 

Hi, Low, Hi

3 short (100ms) tones Hi, Low, Hi indicates a new Fire alarm if Section [023] Option 6 (New Alarms

(Short)

will not disconnect 2-way Audio) is enabled. If disabled the audio session will terminate.

 

NOTE: Receiving a subsequent Fire alarm event tone will not restart the 90 second session timer.

 

 

WWW.DIYALARMFORUM.COM57

Page 61
Image 61
DSCover Satellite Products SCW904x manual Appendix E 2-Way Audio Verification SCW9047 only, Format Reporting Code/Event