1.2 Wiring

1.2 Wiring

1.2 Wiring

1. Zone Wiring

Zones can be wired for Normally Open, Normally Closed Contacts with Single- end-of-line (SEOL) resistors or Double End-of-Line (DEOL) resistors. Observe the following guidelines

For UL/ULC listed installations use SEOL or DEOL only.

Minimum 22 AWG wire, maximum 18 AWG

Do NOT use shielded wire

Wire run resistance shall not exceed 100Ω. Refer to the chart below.

 

Burglary Zone Wiring Chart

Wire

Max wire Length to End-of-line Resistor

Gauge

(feet/meters)

 

 

22

3000 / 914

 

 

20

4900 / 1493

 

 

19

6200 / 1889

 

 

18

7800 / 2377

 

 

Figures are based on maximum wiring resistance of 100Ω

Section [009] Selects Hardwired Zone Definition

Sections [133], [134] Opt [14] selects Normally Closed

Sections [133], [134] Opt [15] selects SEOL resistors

Sections [133], [134] Opt [16] selects DEOL resistors.

Zone Status - Loop Resistance/Loop Status

Fault - 0Ω (shorted wire/loop)

Secure - 5600Ω (contact closed)

Tamper - infinite (broken wire, open)

Violated - 11,200Ω (contact open)

Normally Closed Loops - Do NOT use for UL Installations

Single End-of-Line Resistor Wiring

Double End-of-Line Resistor Wiring

2. PGM/Aux Power Wiring

PGMs switch to ground when activated by control panel.

Connect the plus side of the device to be activated to the AUX+ Terminal. Con- nect the minus terminal to the PGM. Each PGM can provide 50mA output.

NOTE: The control panel can provide a maximum of 100mA of AUX current for PGMs, relays, LED’s etc. Min/Max operating voltages for PGMs, relays and modules is 10.2VDC - 13.75VDC

NOTE: Battery Voltage (6.0-8.4VDC) is boosted internally to supply 12VDC on the AUX+ output by setting Sect[014] Opt[4] to ON. This option must be enabled for PGMs used in UL/ULC Residential Burg installations. This output can NOT be used for UL/ULC Fire installations.

LED output with

I/O

I/O

current limiting

resistor and optional Relay driver output

3. Telephone Line Wiring

Wire the telephone connection terminals (TIP, Ring, T-1, R-1) to an RJ-31x Connector as indicated. Use 24 AWG wire minimum for wiring.

For connection of multiple devices to the telephone line, wire in the sequence indicated.

Communication format is programmed in section [350]. Telephone Call Directions are programmed in section [351]-[376].

T-1 1. Zone WiringBurglary Zone Wiring Chart

R-1 Max wire Length to End-of-line Resistor2. PGM/Aux Power Wiring

TIP 3. Telephone Line Wiring4. Battery

RING 5. AC WiringWWW.DIYALARMFORUM.COM3

BRN

 

GRA

 

GRN

 

RED

RJ-31X

 

Note: For UL Listed Installations,the Installer must verify the communication format with the supervising station at the time of the installation.

4. Battery
5. AC Wiring

A 1500 mAHr Ni-Mh battery pack is included to meet standby power require- ments

NOTE: UL/ULC Residential Burglary installations require 4 Hr. power standby time plus 4 minutes alarm annunciation.

NOTE: UL/ULC Residential Fire installations require 24 Hr. power standby plus 5 minutes alarm annunciation

NOTE: Battery life is 4-5 years under typical operating conditions. Battery capacity deteriorates with age and number of charge/discharge cycles. Replace battery every 4-5 years.

AC Transformer Requirements:

Primary:120VAC, 50/60Hz., 0.33A

240VAC, 50/60Hz., 0.165A Secondary: 16.5VAC/20VA

The following Transformers shall be used:

UL Listed Installations - PTD1620U, PTD1640U (60Hz.) ULC Listed installations - PTD1620, PTD1640 (60Hz.) EU Installations - PTD1620T-EU (50 Hz.)