Section [402] Downloading Computer Phone Number

 

Section 8: Programming Descriptions

[4]

ON: User Initiated Call-up Enabled. The user can initiate a downloading session using the [ ][6] command. OFF: User Initiated

 

Call-up Disabled. The user cannot initiate a downloading session.

[5]Future Use

[6]ON: 300 Baud Panel Call-Up.When the user initiates a DLS connection, the panel will connect and send the initial header at 300

baud. OFF: 110 Baud Panel Call-Up.When the user initiates a DLS connection, the panel will connect and send the initial header at 110 baud. The panel will then switch to 300 baud in order to receive the response from the DLS computer.

[7]-[8] Future Use

Section [402] Downloading Computer Phone Number

The Downloading Computer Telephone Number is used for Call Back and User Initiated DLS functions. Program the phone number as required. HEX digits can be included for special applications:

HEX [A]

Not used

HEX [B]

Simulates a [ ] key press

HEX [C]

Simulates a [#] key press

HEX [D]

Additional dial tone search

HEX [E]

2-second pause

HEX [F]

End of phone number marker

Section [403] Downloading Access Code

Program the 6-digit Downloading Access Code. Upon connection, the system will only connect to the downloading computer if the Downloading Access Code programmed matches the Downloading Access Code programmed in the computer file.

Section [404] Panel Identification Code

Program the 6-digit Panel Identification Code. This code is used by the downloading computer to verify the correct account is calling back (Call Back feature) or to identify which customer account file should be used (User Initiated DLS features).

Section [406] Number of Rings to Answer On

The value in this section determine how many rings that the panel will automatically pick up on in order to establish a DLS connection. Default value is 000 rings. Valid entries are [000]-[009].

If Section [401] Option 1 and Section [406] are both enabled, either one will work depending on how the installer calls the premises.

Section [499] Initiate PC-Link Downloading

Enter the following command to initiate downloading via PC-Link – Section [499] [Installer Code] [499]. Plugging in the PC-Link connec- tor will automatically initiate the connection if DLS is initiated before connecting the PC-Link Header. The session will NOT be automati- cally initiated if the system is in installer mode.

Section [501]-[502] PGM 1 & 2 Output Attributes

Allows the user to customize PGM1 and PGM2 Attributes. The following attributes can be enabled or disabled for each PGM output. When a PGM option is changed, the corresponding PGM’s attributes are defaulted.

The following attributes are available for PGM Output Types [01], [05]-[08] and [17]-[20]. Option Description

[1]-[2] Not Used

[3]ON: True Output. Output will activate (switch to ground) when the event occurs.

OFF: Inverted Output. Output will de-activate (switch to open) when the event occurs.

Section [403] Downloading Access Code This attribute is also available for PGM Output Types [11] and [12].

[4]ON: Output Pulsed. The output will activate for the duration programmed in the PGM Output Timer, Section [170].

OFF: Output On/Off. The output will toggle between on and off when the corresponding [*][7] command is entered.

Section [404] Panel Identification Code This attribute is available only for PGM Output Types [11] and [19]-[20].

[5]ON: Access Code Required for Activation. OFF: No Access Code Required for Activation.

Section [406] Number of Rings to Answer On This attribute is available only for PGM Output Types [19]-[20].

WWW.DIYALARMFORUM.COM41