Appendix A: Reporting Code Formats
Section # | Reporting Code | Code Sent When... | Dialer | Automatic | SIA Auto |
Direction* | Contact ID | Rep Codes** | |||
|
|
| Codes | ||
|
|
|
|
|
|
[347] | Installer Lead In | Installer’s mode has been entered | MA/R | (6)27 | |
|
|
|
|
|
|
[347] | Installer Lead Out | Installer’s mode has been exited | MA/R | (6)28 | |
|
|
|
|
|
|
[348] | Walk Test End | End of test | T | (6) A7 | |
|
|
|
|
|
|
[348] | Walk Test Begin | Beginning of test | T | (6) A7 | |
|
|
|
|
|
|
[348] | Periodic Test | Periodic system test transmission | T | (6) A2 | |
|
|
|
|
|
|
[348] | System Test | [*][6] bell/communications test | T | (6) A1 | |
|
|
|
|
|
|
Closings | System armed (user | O/C | (4) A1 |
| |
|
|
|
|
|
|
Openings | System disarmed (user | O/C | (4) A1 |
| |
|
|
|
|
|
|
* | A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions | ||||
** | UU = user number |
|
|
| |
*** | Use the “Fail to close” event code [(4)54] to report closing or activity delinquency. Ensure the central station is aware that this code is used. | ||||
**** | Zones are panic pendants are identified, wireless keys can be identified for openings and closings. |
|
|
| |
|
|
|
|
|
|
Contact ID Zone Alarm/Restoral Event Codes
(as per SIA DCS: ‘Contact ID’
Program any of these codes for zone alarms/restorals when using the
standard
Medical Alarms |
| (1)34 Entry / Exit |
(1)AA Medical |
| (1)35 Day / Night |
(1)A1 Pendant Transmitter |
| (1)36 Outdoor |
(1)A2 Fail to Report In |
| (1)37 Tamper |
Fire Alarms |
| (1)38 Near Alarm |
(1)1A Fire Alarm |
| General Alarms |
(1)11 Smoke |
| (1)4A General Alarm |
(1)12 Combustion |
| (1)43 Exp. module failure |
(1)13 Water Flow |
| (1)44 Sensor tamper |
(1)14 Heat |
| (1)45 Module Tamper |
(1)15 Pull Station |
| (1)4A Cross Zone Police Code |
(1)16 Duct |
| 24 Hour |
(1)17 Flame |
| (1)5A 24 Hour |
(1)18 Near Alarm |
| (1)51 Gas detected |
Panic Alarms |
| (1)52 Refrigeration |
(1)2A Panic |
| (1)53 Loss of Heat |
(1)21 Duress |
| (1)54 Water Leakage |
(1)22 Silent |
| (1)55 Foil Break |
(1)23 Audible |
| (1)56 Day Trouble |
Burglar Alarms |
| (1)57 Low bottled Gas level |
(1)3A Burglary |
| (1)58 High Temp |
(1)31 Perimeter |
| (1)59 Low Temp |
(1)32 Interior |
| (1)61 Loss of Air Flow |
(1)33 24 Hour |
|
|
SIA Format Automatic Zone Alarm/Restoral Codes
Zone Definition | SIA Auto Rep | Contact ID Auto | ||
| Codes* | Rep Codes* | ||
Delay 1 | (1) | 3A | ||
Delay 2 | (1) | 3A | ||
Instant | (1) | 3A | ||
Interior | (1) | 3A | ||
Interior Stay/Away | (1) | 3A | ||
Delay Stay/Away | (1) | 3A | ||
(1) | 5A | |||
(1) | 5A | |||
(1) | 3A | |||
(1) | 51 | |||
(1) | 58 | |||
(1) | AA | |||
(1) 2A | ||||
(1) A1 | ||||
(1) | 54 | |||
(1) | 59 | |||
Interior Delay | (1) | 3A | ||
Instant Stay/Away | (1) | 3A | ||
(1) | 4A | |||
Night Zone | (1) | 3A | ||
Delayed | (1) | 1A | ||
Standard | (1) | 1A | ||
(1) | 1A |