DSCover Satellite Products SCW904x manual Self Contained Wireless Alarm System, Attribute

Models: SCW904x

1 64
Download 64 pages 52.09 Kb
Page 30
Image 30
[406] Number of Rings To Answer On

Self Contained Wireless Alarm System v1.0

[406] Number of Rings To Answer On

Default 000

I I I I

Valid entries are 000-009, (000 to disable)

[499] Initiate PC-Link Downloading

Enter [499] [Installer Code][499]

[501]-[502] PGM Output Attributes

Program only the following attributes for the PGM options listed. All others will be ignored.

PGM options are programmed in Section [009].

PGM Attribute Defaults (Y = Attribute ON; N = Attribute OFF):

Attribute:

 

1

2

3

4

5

6

7

8

 

 

ON

Not used

Not used

True Output

Follows Timer

Code Req.

Not used

Not used

Not used

 

 

OFF

Inverted

On / Off

No Code Req.

 

 

 

 

 

 

 

 

 

 

PGM Option

 

 

 

 

 

 

 

 

 

[00]

Null PGM (Not Used)

 

 

 

 

 

 

 

 

 

[01]

Residential Burglary / Fire Bell Output

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[05]

System Armed Status

 

 

 

Y

 

 

 

 

 

[06]

Ready To Arm

 

 

 

Y

 

 

 

 

 

[07]

Keypad Buzzer follows PGM

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[08]

Courtesy Pulse

 

 

 

Y

 

 

 

 

 

[09]

System Trouble (See Table Below)

Y

Y

Y

Y

Y

Y

Y

Y

[10]

System Event (See Table Below)

Y

Y

Y

Y

Y

Y

Y

N

 

 

 

 

 

 

 

 

 

 

[11]

System Tamper (all sources, zones, keypad, modules)

 

 

Y

N

 

 

 

 

[12]

TLM and Alarm

 

 

 

Y

 

 

 

 

 

[17]

Away Armed Status

 

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[18]

Stay Armed Status

 

 

 

Y

 

 

 

 

 

[19]

Command Output #1, [

][7][1]

 

 

Y

Y

Y

 

 

 

[20]

Command Output #2, [

][7][2]

 

 

Y

Y

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Attribute:

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

ON

Serv Req

AC Fail.

TLM Fault

FTC

Zone Fault

Zone Tamper

Zone Low

Loss of Clock

 

Evnt.

 

 

 

 

 

Batt

 

OFF

Disabled

Disabled

Disabled

Disabled

Disabled

Disabled

Disabled

Disabled

PGM Option

 

 

 

 

 

 

 

 

[9] System Trouble

Y

Y

Y

Y

Y

Y

Y

Y

 

 

 

 

 

 

 

 

 

Attribute:

 

1

2

3

4

5

6

7

8

 

ON

Burg Event

Fire Event

Panic Event

Medical

Supervisory

Priority Event

Duress Event

Follows Timer

 

 

 

 

 

Event

Event

 

 

 

 

OFF

Disabled

Disabled

Disabled

Disabled

Disabled

Disabled

Disabled

Latched

 

 

 

 

 

 

 

 

 

 

PGM Option

 

 

 

 

 

 

 

 

 

[10] System Event

 

Y

Y

Y

Y

Y

Y

Y

N

 

 

 

 

 

 

 

 

 

 

Section PGM

Output

1

2

3

4

5

6

7

8

#

Type*

 

 

 

 

 

 

 

 

Main Board

 

 

 

 

 

 

 

 

 

[501] 1 ( )

[502] 2 ( )

I

I

I

I

I

I

I

I

I

I

I

I

I

I

I

I

I

I

I

I

*Record here based on programming in Section [009].

26WWW.DIYALARMFORUM.COM

Page 30
Image 30
DSCover Satellite Products SCW904x manual Self Contained Wireless Alarm System, Number of Rings To Answer On, Attribute