DeWalt DeVILBISS manual Before Each Start-Up, How to Start

Models: DeVILBISS

1 92
Download 92 pages 33.85 Kb
Page 17
Image 17

minutes. Make sure the drain valve is open and there is minimal air pressure build-up in tank.

7.After 20 minutes, close the drain valve (clockwise). The air receiver will fill to "cut-out" pressure and the motor will stop.

The compressor is now ready for use.

Before Each Start-Up:

1.Place On/Auto/Off lever to "Off".

2.Check oil level in pump. See "Oil" paragraph in the "Maintenance" section for instructions.

3.Pull regulator knob out, turn counter-clockwise until it stops. Push knob in to lock in place.

4.Attach hose and accessories. NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect.

Too much air pressure causes a

hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

How to Start:

1.Turn the On/Auto/Off lever to "On/Auto" and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure.

2.Pull the regulator knob out and turn clockwise to increase pressure. When the desired pressure is reached push knob in to lock in place. The compressor is ready for use.

NOTE: Always operate the air compressor in well-ventilated areas free of gasoline or other combustible vapors. If the compressor is being used to operate a sprayer DO NOT place near the spray area.

17- ENG

D23766

Page 17
Image 17
DeWalt DeVILBISS manual Before Each Start-Up, How to Start