DeWalt DeVILBISS manual Voltage and Circuit Protection, 120/240 Dual Voltage Motor

Models: DeVILBISS

1 92
Download 92 pages 33.85 Kb
Page 13
Image 13

Voltage and Circuit Protection

Refer to the Parts Manual for the voltage and minimum branch circuit requirements.

Certain air compressors can be operated on a 15 amp circuit if the following conditions are met.

1.Voltage supply through branch circuit is 15 amps.

2.Circuit is not used to supply any other electrical needs (lights, appliances, etc.).

3.Extension cords comply with specifications.

4.Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay fuse. NOTE: If compressor is connected to a circuit protected by fuses, use only time delay fuses marked "D" in Canada and "T" in the US.

If any of the above conditions cannot be met, or if operation of the compressor repeatedly causes interruption of the power, it may be necessary to operate it from a 20 amp circuit. It is not necessary to change the cord set.

120/240 Dual Voltage Motor

This model has a dual voltage motor, 120 and 240 volt. It is wired for 120 volt but can be converted to 240 volt operation. Instructions for connecting the motor for operation at 240 volt can be found printed on the label attached to the side of the motor.

When converting to 240V operation, the

attached three-prong 120V cord assembly must be replaced with a three-pronged 240V cord assembly (K-0080) that can be purchased through a Sears Service Center.

 

 

 

 

 

120 Volt Plug

 

 

 

 

240 Volt Plug

 

Air Distribution System

Plastic or PVC pipe is not

designed for use with compressed air. Regardless of its indicated pressure rating, plastic pipe can burst from air pressure. Use only metal pipe for air distribution lines.

The next figure represents a typical air distribution system. The following are tips to remember when setting up the air compressor’s air distribution system.

13- ENG

D23766

Page 13
Image 13
DeWalt DeVILBISS manual Voltage and Circuit Protection, 120/240 Dual Voltage Motor, Air Distribution System