•Use pipe that is the same size as the air tank outlet. Piping that is too small will restrict the flow of air.
•If piping is over 100 feet long, use the next larger size.
•Bury underground lines below the frost line and avoid pockets where condensation can gather and freeze. Apply pressure before underground lines are covered to make sure all pipe joints are free of leaks.
•A flexible coupling is recommended to be installed between the air discharge outlet and main air distribution line to allow for vibration.
•A separate regulator is recommended to control the air pressure. Air pressure from the tank is usually to high for individual air driven tools.
AIR FLOW | FEEDER LINES SLOPE |
| |
WITH AIR FLOW | AIR FLOW | ||
|
MAIN DISTRIBUTION AIR LINES Slope pipe in direction of air flow. Water condensate flows along bottom of pipe to drain legs, preventing it from entering feeder lines.
REGULATOR
LUBRICATOR
DRAIN
TRAP
MOISTURE
SEPARATOR
AND TRAP
AIR USAGE
LINES
DIRT
LEG
FILTER
FLEXIBLE
COUPLING
DRAIN
LEGS
DRAIN
TRAPS
REGULATOR
LUBRICATOR
AIR DISCHARGE
DIRTVALVE
LEG
AIR
COMPRESSOR
TYPICAL COMPRESSED
AIR DISTRIBUTION SYSTEM
DRAIN COCK
VALVE
D23766 | 14- ENG |