Use pipe that is the same size as the air tank outlet. Piping that is too small will restrict the flow of air.

If piping is over 100 feet long, use the next larger size.

Bury underground lines below the frost line and avoid pockets where condensation can gather and freeze. Apply pressure before underground lines are covered to make sure all pipe joints are free of leaks.

A flexible coupling is recommended to be installed between the air discharge outlet and main air distribution line to allow for vibration.

A separate regulator is recommended to control the air pressure. Air pressure from the tank is usually to high for individual air driven tools.

AIR FLOW

FEEDER LINES SLOPE

 

WITH AIR FLOW

AIR FLOW

 

MAIN DISTRIBUTION AIR LINES Slope pipe in direction of air flow. Water condensate flows along bottom of pipe to drain legs, preventing it from entering feeder lines.

REGULATOR

LUBRICATOR

DRAIN

TRAP

MOISTURE

SEPARATOR

AND TRAP

AIR USAGE

LINES

DIRT

LEG

FILTER

FLEXIBLE

COUPLING

DRAIN

LEGS

DRAIN

TRAPS

REGULATOR

LUBRICATOR

AIR DISCHARGE

DIRTVALVE

LEG

AIR

COMPRESSOR

TYPICAL COMPRESSED

AIR DISTRIBUTION SYSTEM

DRAIN COCK

VALVE

D23766

14- ENG

Page 14
Image 14
DeWalt DeVILBISS manual Typical Compressed AIR Distribution System