Desa DVFE34 REMOVING/REPLACING Glass Door, Installing Optional Wall Mount Switch GWMS2

Page 21

OWNER’S MANUAL

FIREPLACE INSTALLATION

Continued

REMOVING/REPLACING GLASS DOOR

You must remove glass door to install optional brickliners,logs,lavarock,andembermaterial.

CAUTION: Do not operate this fireplace with a broken glass door panel. Do not operate this fire- place without the glass door panel securely in place. For replace- ment part information see Re- placement Parts, page 30.

1.Remove the upper louver panel by lift- ing upward and out (see Figure 39).

2.Remove the screws from the three tabs at the top of the glass door while hold- ing door securely keeping it from fall- ing forward.

3.Grasp door by both sides and ease it upward off of the lower bracket (see Figure 40).

4.To replace glass door, follow the above instructions in reverse.

Top Louver

Panel

Glass Door

Assembly

Screw

Lower Bracket for Glass Door Assembly

Figure 40 -Removing/ReplacingGlassDoor

INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2

NOTICE: The GWMS2 includes 25' of wire for installation. Your fireplace includes 15' of wire for accessory installation. Choose the length that best fits your needs when installing this accessory.

The installation of a wall switch allows you to activate the gas control valve and turn the fireplace on and off. The wall switch is to be connected to the incoming 120 volt regular household wiring that supplies electricity to the fireplace. Refer to wiring diagram on page 30.

2.Activate the remote handset battery by removing the insulating tab on the back of the handset (see Figure 42). The bat- tery is included pre-installed.

3.Once the battery is activated the unit is ready to use.

Junction

Remote

Box

 

Control

 

Receiver

Extension

 

Cord

Ignition

 

Module Plug

Figure 41 - Installing the WRC Remote Receiver

Battery Cover

12 Volt Battery

Back of Handset

Figure 39 - Removing Top Louver Panel

OPTIONAL REMOTE CONTROL INSTALLATION (Model WRC)

Note: If using optional wireless hand-held remote control, the wall switch must be in the ON position to be operational. The re- mote control then becomes the switching mechanism for fireplace operation.

1.The WRC model receiver does not re- quire a battery. The receiver can be in- stalled by first plugging the short ex- tension cord into the fireplace junction box. Then plug the receiver unit into the extension cord. Finally plug the ig- nition module plug into the receiver unit (see Figure 41).

Pull to Remove

Insulation Tab

Figure 42 - Installing Battery into Back of Handset

Continued

107205

21

For more information, visit www.desatech.com

Image 21
Contents For Your Safety For Your Safety What to do if YOU Smell GASDVFE34 Natural Electronic Ignition DIRECT-VENT Fireplace Safety InformationLocal Codes Product IdentificationGlossary Terms OperationLocation and Space Requirements PRE-INSTALLATION PreparationClearances Framing and FinishingPRE-INSTALLATION General Venting Preparation Location of VentTermination General Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseSnorkel Termination Installation for Horizontal TerminationFor vinyl siding use vinyl siding stand Rigid Vent Pipe Horizontal Venting Rigid Vent Pipe Horizontal Termination ConfigurationsVenting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Venting with Two 90 Elbow s Vertical Termination ConfigurationsVertical Venting High Altitude Installation Parts Lists for Venting Kits and ComponentsFMI Rigid Venting Installing Optional Blower Accessory Fireplace InstallationInstalling GA3700/DA3610TA Blowers Check GAS TypeIf your fireplace system is installed Installation Items Needed Installing GAS Piping to Fireplace LocationConnecting Fireplace to GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections Close equipment shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsREMOVING/REPLACING Glass Door Installing Optional Wall Mount Switch GWMS2Attaching Magnetic Decorative Brass Strips Installing Optional Brick Liner D8037AInstalling Log No Installing LOGS, Lava Rock and Glowing EmbersOperating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To ApplianceOperating Optional GWMS2 Wall Mounted Switch Operating Optional Blower AccessoryPilot Assembly Inspecting BurnersGlass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause Remedy TroubleshootingOrifice Gas leak. See Warning statement Service Hints Replacement PartsTechnical Service Wiring DiagramsDVFE34 SpecificationsDVFE34 Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListAccessories 107205 Warranty Information

DVFE34 specifications

Desa DVFE34 is a cutting-edge development designed to meet the demanding needs of modern urban living. This residential complex stands out due to its innovative architecture, sustainable technologies, and its commitment to enhancing the quality of life for its residents.

One of the main features of Desa DVFE34 is its environmentally friendly design. The complex has been constructed with sustainable materials that minimize its carbon footprint. Solar panels are integrated into the building's structure, providing renewable energy for common areas and reducing reliance on non-renewable power sources. The implementation of rainwater harvesting systems ensures efficient use of water resources, promoting sustainability within the community.

In terms of technology, Desa DVFE34 is equipped with smart home capabilities. Residents can control various aspects of their homes—from lighting to heating—through a centralized app on their smartphones. This not only adds convenience but also allows for energy savings and enhances security. The incorporation of security systems with smart alarms and surveillance cameras ensures a safe living environment.

The layout of the building is thoughtfully designed to maximize space and comfort. Spacious apartments come with modern finishes, high ceilings, and large windows that allow plenty of natural light to flow in. Common areas include beautifully landscaped gardens, recreational spaces, and fitness facilities that encourage a healthy lifestyle. Additionally, designated areas for social gatherings foster a sense of community among residents.

Accessibility is a key characteristic of Desa DVFE34. Located in a prime urban area, residents have easy access to public transport, shopping centers, and essential services. This not only facilitates daily commutes but also enhances the overall living experience by placing residents in the heart of the city’s amenities.

In summary, Desa DVFE34 represents a harmonious blend of modern living and sustainable practices. Its innovative features, from smart technologies to eco-friendly designs, set a new standard for urban residential developments. By prioritizing both comfort and sustainability, Desa DVFE34 is an exemplary model of what future living spaces can and should be.