Desa DVFE34 installation manual Installation for Horizontal Termination, Snorkel Termination

Page 8

DIRECT-VENT FIREPLACE

VENTING INSTALLATION

Continued

INSTALLATION FOR HORIZONTAL TERMINATION

1.Determine the route your horizontal venting will take. Note: The location of the horizontal vent termination on the exterior wall must meet all local and national building codes and must not be easily blocked or obstructed.

WARNING: Do not recess vent terminal into a wall or siding.

Snorkel terminations are available for terminations requiring a vertical rise on the exterior of the building (see Figures 9 and 10). Follow the same installation procedures as used for standard horizon- tal terminations. If installing the snor- kel termination below grade (basement applications), you must provide proper drainage to prevent water from entering the snorkel termination (see Figure 10). Do not back fill around the snorkel ter- mination.

2.Rigid vent pipes and fittings have spe- cial twist-lock connections. Assemble the desired combination of pipe and el- bows to the appliance adaptor with pipe seams oriented towards the wall or floor.

Twist-lock Procedure: The female ends of the pipes and fittings have four locking lugs (indentations). These lugs will slide straight into matching slots on the male ends of adjacent pipes and fit- tings. (All connections must be sealed with high temperature silicone sealant as specified in the second warning state- ment on page 7.) Push the pipe sections together and twist one section clockwise approximately one-quarter turn until the sections are fully locked. See Figure 11, page 9. Note: Horizontal runs of vent must be supported every three feet. Use wall straps for this purpose.

Snorkel

12" Minimum

Figure 9 - Snorkel Termination

Snorkel

12" Minimum

Adequate

Drainage

Figure 10 - Snorkel Termination with Drainage Pipe

For more information, visit www.desatech.com

8

107205

Image 8
Contents DVFE34 Natural Electronic Ignition For Your SafetyFor Your Safety What to do if YOU Smell GAS Safety Information DIRECT-VENT FireplaceProduct Identification Local CodesGlossary Terms OperationPRE-INSTALLATION Preparation Location and Space RequirementsClearances Framing and FinishingTermination PRE-INSTALLATION General Venting PreparationLocation of Vent General Venting Venting Installation Installation PrecautionsInstallation Planning Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationFor vinyl siding use vinyl siding stand Rigid Vent Pipe Horizontal Termination Configurations Rigid Vent Pipe Horizontal VentingVenting with Two 90 Elbows Cathedral Ceiling Installation Installation for Vertical TerminationFlat Ceiling Installation Vertical Termination Configurations Venting with Two 90 Elbow sVertical Venting FMI Rigid Venting High Altitude InstallationParts Lists for Venting Kits and Components Fireplace Installation Installing Optional Blower AccessoryInstalling GA3700/DA3610TA Blowers Check GAS TypeIf your fireplace system is installed Installing GAS Piping to Fireplace Location Installation Items NeededChecking GAS Connections Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas Connections Close equipment shutoff valve see Fig- ureInstalling Optional Wall Mount Switch GWMS2 REMOVING/REPLACING Glass DoorInstalling Optional Brick Liner D8037A Attaching Magnetic Decorative Brass StripsInstalling LOGS, Lava Rock and Glowing Embers Installing Log NoFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions To Turn OFF GAS To ApplianceOperating Optional Blower Accessory Operating Optional GWMS2 Wall Mounted SwitchPilot Assembly Inspecting BurnersCleaning and Maintenance Glass DoorPilot and Burners LogsTroubleshooting Observed Problem Possible Cause RemedyOrifice Gas leak. See Warning statement Replacement Parts Service HintsTechnical Service Wiring DiagramsSpecifications DVFE34Illustrated Parts Breakdown DVFE34Parts List KEY Part Number Description QTYAccessories 107205 Warranty Information

DVFE34 specifications

Desa DVFE34 is a cutting-edge development designed to meet the demanding needs of modern urban living. This residential complex stands out due to its innovative architecture, sustainable technologies, and its commitment to enhancing the quality of life for its residents.

One of the main features of Desa DVFE34 is its environmentally friendly design. The complex has been constructed with sustainable materials that minimize its carbon footprint. Solar panels are integrated into the building's structure, providing renewable energy for common areas and reducing reliance on non-renewable power sources. The implementation of rainwater harvesting systems ensures efficient use of water resources, promoting sustainability within the community.

In terms of technology, Desa DVFE34 is equipped with smart home capabilities. Residents can control various aspects of their homes—from lighting to heating—through a centralized app on their smartphones. This not only adds convenience but also allows for energy savings and enhances security. The incorporation of security systems with smart alarms and surveillance cameras ensures a safe living environment.

The layout of the building is thoughtfully designed to maximize space and comfort. Spacious apartments come with modern finishes, high ceilings, and large windows that allow plenty of natural light to flow in. Common areas include beautifully landscaped gardens, recreational spaces, and fitness facilities that encourage a healthy lifestyle. Additionally, designated areas for social gatherings foster a sense of community among residents.

Accessibility is a key characteristic of Desa DVFE34. Located in a prime urban area, residents have easy access to public transport, shopping centers, and essential services. This not only facilitates daily commutes but also enhances the overall living experience by placing residents in the heart of the city’s amenities.

In summary, Desa DVFE34 represents a harmonious blend of modern living and sustainable practices. Its innovative features, from smart technologies to eco-friendly designs, set a new standard for urban residential developments. By prioritizing both comfort and sustainability, Desa DVFE34 is an exemplary model of what future living spaces can and should be.