Desa K36EN, K36EP Product Identification, Local Codes, Continued, Safety Information

Page 3
Continued

SAFETY INFORMATION PRODUCT IDENTIFICATION LOCAL CODES

3

SAFETY INFORMATION

Continued

5.This fireplace reaches high temperatures. Keep children and adults away from hot surfaces to avoid burns or clothing igni- tion. Fireplace will remain hot for a time after shutdown. Al- low surfaces to cool before touching.

6.Carefully supervise young children when they are in the room with fireplace.

7.Do not modify this fireplace under any circumstances. Any parts removed for servicing must be replaced prior to operat- ing fireplace.

8.Turn fireplace off and let cool before servicing, installing, or repairing. Only a qualified service person should install, ser- vice, or repair this fireplace. Have fireplace inspected annu- ally by a qualified service person.

9.You must keep control compartments, burners, and circulat- ing air passages clean. More frequent cleaning may be needed due to excessive lint and dust from carpeting, bedding mate- rial, etc. Turn off the gas valve and pilot light before cleaning fireplace.

10.Have venting system inspected annually by a qualified service person. If needed, have venting system cleaned or repaired. See Cleaning and Maintenance, page 26.

11.Keep the area around your fireplace clear of combustible ma- terials, gasoline, and other flammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around fireplace.

12.Do not use this fireplace to cook food or burn paper or other objects.

13.Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fireplace nameplate.

14.This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Ca- nadian Electrical Code, CSA C22.1.

15.Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service person to arrange for replacement of the unit.

16.Do not operate fireplace if any log is broken.

17.Do not use a blower insert, heat exchanger insert, or other ac- cessory not approved for use with this fireplace.

18.Do not operate fireplace with glass door removed, cracked, or broken.

19.Provide adequate clearances around air openings.

PRODUCT IDENTIFICATION

Upper Louver

 

Panel

Flue Collar

 

Nailing

 

 

Flange

 

 

Glass

 

Log

 

Set

Door

 

 

 

Assembly

 

 

 

 

Lava

 

 

Rock

Lower

 

 

Louver

 

 

Panel

 

 

Control

Glowing

 

Valve with

 

Embers

 

Piezo Ignitor

Burner

 

Assembly

Switch Bracket for

 

 

Optional Remote and

 

Blower

Figure 1 - Direct-Vent Fireplace with Electronic Ignition

LOCAL CODES

Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANSI Z223.1/NFPA 54* (USA) or the current CSA-B149.1 Instal- lation Code (Canada).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

PRODUCT IDENTIFICATIONFor moreLOCAL CODESFor morevisit www..comManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

111924-01A

Image 3
Contents DIRECT-VENTFIREPLACE OWNER’S OPERATION AND INSTALLATION MANUALNATURAL GAS MODELS VK36EN SERIES PROPANE/LP GAS MODELS VK36EP SERIESSAFETY INFORMATION TABLE OF CONTENTSSAFETY INFORMATION PRODUCT IDENTIFICATIONLOCAL CODES ContinuedPRODUCT FEATURES PRE-INSTALLATION PREPARATIONLOCATION AND SPACE REQUIREMENTS FRAMING AND FINISHING PRE-INSTALLATION PREPARATIONContinued CLEARANCESLOCATION OF TERMINATION CAP LOCATION OF TERMINATION CAPD E B L V G V AINSTALLATION PRECAUTIONS VENTING INSTALLATION INSTRUCTIONSContinued VENTING INSTALLATION INSTRUCTIONSINSTALLATION PLANNING Horizontal Termination InstallationExterior VENTING INSTALLATION INSTRUCTIONSVENTING INSTALLATION INSTRUCTIONS ContinuedContinued VENTING INSTALLATION INSTRUCTIONSHorizontal Termination Configurations VENTING INSTALLATION INSTRUCTIONSVENTING INSTALLATION INSTRUCTIONS ContinuedRecommended Applications Venting with Two 90 Elbows VENTING INSTALLATION INSTRUCTIONSContinued Venting with Two 90 ElbowsContinued VENTING INSTALLATION INSTRUCTIONSINSTALLATION FOR VERTICAL TERMINATION Flat Ceiling InstallationVenting with Two 90 Elbows VENTING INSTALLATION INSTRUCTIONSVertical Termination Configurations ContinuedVertical Venting VENTING INSTALLATION INSTRUCTIONSHIGH ALTITUDE INSTALLATION ContinuedModel BK Installation FIREPLACE INSTALLATIONVENTING INSTALLATION INSTRUCTIONS PARTS LISTS FOR VENTING KITS AND COMPONENTSFIREPLACE INSTALLATION Model BKT InstallationContinued Continued FIREPLACE INSTALLATIONINSTALLING GAS PIPING TO FIREPLACE LOCATION Blower Wiring DiagramContinued FIREPLACE INSTALLATIONInstallation Items Needed Pressure Testing Gas Supply Piping SystemRemoving Louver Panels FIREPLACE INSTALLATIONPressure Testing Fireplace Gas Connections ContinuedContinued FIREPLACE INSTALLATIONCleaning Glass Door See Cleaning and Maintenance on pageContinued FIREPLACE INSTALLATIONINSTALLING LOGS, LAVA ROCK AND GLOWING EMBERS WALL SWITCH INSTALLATIONContinued WIRING DIAGRAMFIREPLACE INSTALLATION OPTIONAL REMOTE CONTROL INSTALLATION Model WRCTO TURN OFF GAS TO APPLIANCE OPERATING FIREPLACEFOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONSOPERATING FIREPLACE INSPECTING BURNERSOPERATING OPTIONAL BLOWER ACCESSORY PILOT ASSEMBLYLOGS CLEANING AND MAINTENANCEGLASS DOOR PILOT AND BURNERSREMEDY TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEPOSSIBLE CAUSE TROUBLESHOOTINGOBSERVED PROBLEM ContinuedSPECIFICATIONS REPLACEMENT PARTSSERVICE HINTS TECHNICAL SERVICEILLUSTRATED PARTS BREAKDOWN MODELS VK36EN, VK36ENH, VK36EP, VK36EPHILLUSTRATED PARTS BREAKDOWN PARTS LIST PARTS LISTILLUSTRATED PARTS BREAKDOWN PARTS LIST PARTS LIST111957-01 ACCESSORIES OWNERS REGISTRATION FORM Postage Required TAPETAPE Page WARRANTY INFORMATION LIMITED WARRANTY DIRECT-VENTFIREPLACENOT A UPC