OPERATING FIREPLACE

24

OPERATING FIREPLACE

For Your Safety Read Before Lighting

 

Lighting Instructions

 

To Turn Off Gas To Appliance

 

Optional Remote Operation

 

 

OPERATING FIREPLACE

FOR YOUR SAFETY

READ BEFORE LIGHTING

FOR YOUR SAFETY WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

NOTICE: During initial operation of new heater, burn- ing logs will give off a paper-burning smell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

1.STOP! Read the safety information, above.

2.Turn off all electric power to the appliance.

3.Turn wall switch to the OFF position.

4.Open lower louver panel.

5. Turn equipment shutoff valve clockwise ClockwiseLIGHTING to the OFF position (see Figure 47). Do not force.

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information above. If you don’t smell gas, go to the next step.

7.Turn equipment shutoff valve counterclockwise TO TURN OFF GASC-clockwiseto the ON position. Do not force.

8.Close lower louver panel.

9.Turn on all electric power to the appliance.

10.Turn the wall switch to the ON position.

11.Visually locate the pilot. The ignitor should begin to spark and the main burner should ignite once flame appears at pilot.

If lighting the appliance for the first time each season, it may take several attempts before the supply gas can reach the pilot and main burners.

If the appliance will not stay lit after several attempts, follow the instructions To Turn Off Gas To Appliance, be- low, and call your service technician or gas supplier.

Equipment Shutoff Valve

Adjustment

Screw

Figure 47 - Turning Equipment Shutoff Valve to the OFF Position

TO TURN OFF GAS

TO APPLIANCE

1.Turn off the wall switch.

2.Turn off all electric power to the appliance if service is to be performed.

3.Open lower louver panel.

4.Remove front hearth brick and control access panel.

5. Turn equipment shutoff valve clockwise ClockwiseOPTIONAL REMOTE to OFF.

Do not force.

6.Close lower louver panel.

Manual background Sensing Rod

Pilot Burner

Ignitor

Figure 48 - Pilot

OPTIONAL REMOTE

OPERATION

Note: The WRC receiver and hand-held remote control kit must be purchased separately (see Accessories, page 34). Follow installation instructions on page 23.

1.Turn equipment shutoff valve to ON position.You can now turn the burner on and off with the hand-held remote control unit. IMPORTANT: Be sure to press the ON/OFF buttons on the hand-held remote control unit for up to 3 seconds to assure proper operation.

2.Press the ON/OFF button to turn the burner on and off.

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

111924-01A

Image 24
Contents OWNER’S OPERATION AND INSTALLATION MANUAL NATURAL GAS MODELS VK36EN SERIES PROPANE/LP GASMODELS VK36EP SERIES DIRECT-VENTFIREPLACETABLE OF CONTENTS SAFETY INFORMATIONPRODUCT IDENTIFICATION LOCAL CODESContinued SAFETY INFORMATIONPRODUCT FEATURES PRE-INSTALLATION PREPARATIONLOCATION AND SPACE REQUIREMENTS PRE-INSTALLATION PREPARATION ContinuedCLEARANCES FRAMING AND FINISHINGLOCATION OF TERMINATION CAP D E B LV G V A LOCATION OF TERMINATION CAPVENTING INSTALLATION INSTRUCTIONS INSTALLATION PRECAUTIONSVENTING INSTALLATION INSTRUCTIONS INSTALLATION PLANNINGHorizontal Termination Installation ContinuedVENTING INSTALLATION INSTRUCTIONS VENTING INSTALLATION INSTRUCTIONSContinued ExteriorVENTING INSTALLATION INSTRUCTIONS Horizontal Termination ConfigurationsVENTING INSTALLATION INSTRUCTIONS ContinuedVENTING INSTALLATION INSTRUCTIONS ContinuedRecommended Applications VENTING INSTALLATION INSTRUCTIONS ContinuedVenting with Two 90 Elbows Venting with Two 90 ElbowsVENTING INSTALLATION INSTRUCTIONS INSTALLATION FOR VERTICAL TERMINATIONFlat Ceiling Installation ContinuedVENTING INSTALLATION INSTRUCTIONS Vertical Termination ConfigurationsContinued Venting with Two 90 ElbowsVENTING INSTALLATION INSTRUCTIONS HIGH ALTITUDE INSTALLATIONContinued Vertical VentingFIREPLACE INSTALLATION VENTING INSTALLATION INSTRUCTIONSPARTS LISTS FOR VENTING KITS AND COMPONENTS Model BK InstallationFIREPLACE INSTALLATION Model BKT InstallationContinued FIREPLACE INSTALLATION INSTALLING GAS PIPING TO FIREPLACE LOCATIONBlower Wiring Diagram ContinuedFIREPLACE INSTALLATION Installation Items NeededPressure Testing Gas Supply Piping System ContinuedFIREPLACE INSTALLATION Pressure Testing Fireplace Gas ConnectionsContinued Removing Louver PanelsFIREPLACE INSTALLATION Cleaning Glass DoorSee Cleaning and Maintenance on page ContinuedFIREPLACE INSTALLATION INSTALLING LOGS, LAVA ROCK AND GLOWING EMBERSWALL SWITCH INSTALLATION ContinuedWIRING DIAGRAM FIREPLACE INSTALLATIONOPTIONAL REMOTE CONTROL INSTALLATION Model WRC ContinuedOPERATING FIREPLACE FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCEINSPECTING BURNERS OPERATING OPTIONAL BLOWER ACCESSORYPILOT ASSEMBLY OPERATING FIREPLACECLEANING AND MAINTENANCE GLASS DOORPILOT AND BURNERS LOGSTROUBLESHOOTING OBSERVED PROBLEMPOSSIBLE CAUSE REMEDYTROUBLESHOOTING OBSERVED PROBLEMContinued POSSIBLE CAUSEREPLACEMENT PARTS SERVICE HINTSTECHNICAL SERVICE SPECIFICATIONSILLUSTRATED PARTS BREAKDOWN MODELS VK36EN, VK36ENH, VK36EP, VK36EPHILLUSTRATED PARTS BREAKDOWN PARTS LIST PARTS LISTILLUSTRATED PARTS BREAKDOWN PARTS LIST PARTS LIST111957-01 ACCESSORIES OWNERS REGISTRATION FORM Postage Required TAPETAPE Page WARRANTY INFORMATION LIMITED WARRANTY DIRECT-VENTFIREPLACENOT A UPC