Desa K36EN, K36EP Venting Installation Instructions, Continued, High Altitude Installation

Page 15
Vertical Venting

VENTING INSTALLATION INSTRUCTIONS

Continued

Vertical Venting

V = 40' max.

Note: Install restrictor into inner collar of fireplace as shown.

45° Elbow

VENTING INSTALLATION INSTRUCTIONS

15

Installation for Vertical Termination (Cont.)

High Altitude Installation

 

 

 

HIGH ALTITUDE INSTALLATION

Your DESA direct-vent fireplace has been tested and approved for elevations from 0-2000 feet (USA) and elevations from 0-4500 feet (Canada) .

When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification.

When installing this fireplace at an elevation above 4500 feet (in Canada), check with local authorities.

Consult your local gas company to help determine the proper orifice for your location.

For assistance with any high altitude installation contact DESA’s Customer Service Department at 1-866-672-6040.

Figure 24 - Vertical Venting Configuration With No Horizontal

Run (Vertical Round High Wind Termination Shown)

HIGH ALTITUDE INSTALLATIONFor moreManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

111924-01A

Image 15
Contents DIRECT-VENTFIREPLACE OWNER’S OPERATION AND INSTALLATION MANUALNATURAL GAS MODELS VK36EN SERIES PROPANE/LP GAS MODELS VK36EP SERIESSAFETY INFORMATION TABLE OF CONTENTSSAFETY INFORMATION PRODUCT IDENTIFICATIONLOCAL CODES ContinuedPRODUCT FEATURES PRE-INSTALLATION PREPARATIONLOCATION AND SPACE REQUIREMENTS FRAMING AND FINISHING PRE-INSTALLATION PREPARATIONContinued CLEARANCESLOCATION OF TERMINATION CAP LOCATION OF TERMINATION CAPD E B L V G V AINSTALLATION PRECAUTIONS VENTING INSTALLATION INSTRUCTIONSContinued VENTING INSTALLATION INSTRUCTIONSINSTALLATION PLANNING Horizontal Termination InstallationExterior VENTING INSTALLATION INSTRUCTIONSVENTING INSTALLATION INSTRUCTIONS ContinuedContinued VENTING INSTALLATION INSTRUCTIONSHorizontal Termination Configurations VENTING INSTALLATION INSTRUCTIONSVENTING INSTALLATION INSTRUCTIONS ContinuedRecommended Applications Venting with Two 90 Elbows VENTING INSTALLATION INSTRUCTIONSContinued Venting with Two 90 ElbowsContinued VENTING INSTALLATION INSTRUCTIONSINSTALLATION FOR VERTICAL TERMINATION Flat Ceiling InstallationVenting with Two 90 Elbows VENTING INSTALLATION INSTRUCTIONSVertical Termination Configurations ContinuedVertical Venting VENTING INSTALLATION INSTRUCTIONSHIGH ALTITUDE INSTALLATION ContinuedModel BK Installation FIREPLACE INSTALLATIONVENTING INSTALLATION INSTRUCTIONS PARTS LISTS FOR VENTING KITS AND COMPONENTSFIREPLACE INSTALLATION Model BKT InstallationContinued Continued FIREPLACE INSTALLATIONINSTALLING GAS PIPING TO FIREPLACE LOCATION Blower Wiring DiagramContinued FIREPLACE INSTALLATIONInstallation Items Needed Pressure Testing Gas Supply Piping SystemRemoving Louver Panels FIREPLACE INSTALLATIONPressure Testing Fireplace Gas Connections ContinuedContinued FIREPLACE INSTALLATIONCleaning Glass Door See Cleaning and Maintenance on pageContinued FIREPLACE INSTALLATIONINSTALLING LOGS, LAVA ROCK AND GLOWING EMBERS WALL SWITCH INSTALLATIONContinued WIRING DIAGRAMFIREPLACE INSTALLATION OPTIONAL REMOTE CONTROL INSTALLATION Model WRCTO TURN OFF GAS TO APPLIANCE OPERATING FIREPLACEFOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONSOPERATING FIREPLACE INSPECTING BURNERSOPERATING OPTIONAL BLOWER ACCESSORY PILOT ASSEMBLYLOGS CLEANING AND MAINTENANCEGLASS DOOR PILOT AND BURNERSREMEDY TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEPOSSIBLE CAUSE TROUBLESHOOTINGOBSERVED PROBLEM ContinuedSPECIFICATIONS REPLACEMENT PARTSSERVICE HINTS TECHNICAL SERVICEILLUSTRATED PARTS BREAKDOWN MODELS VK36EN, VK36ENH, VK36EP, VK36EPHILLUSTRATED PARTS BREAKDOWN PARTS LIST PARTS LISTILLUSTRATED PARTS BREAKDOWN PARTS LIST PARTS LIST111957-01 ACCESSORIES OWNERS REGISTRATION FORM Postage Required TAPETAPE Page WARRANTY INFORMATION LIMITED WARRANTY DIRECT-VENTFIREPLACENOT A UPC