Desa K36EN, K36EP Troubleshooting, Observed Problem, Possible Cause, Remedy, ment Parts, page

Page 27
TROUBLESHOOTING

TROUBLESHOOTING

27

TROUBLESHOOTING

Note: For additional help, visit DESA’s technical service web site at www.desatech.com.

Note: Before troubleshooting the system, make sure the gas shutoff valve is ON.

WARNING: Turn off heater

 

CAUTION: Never use a wire,

and let cool before servicing. Only

 

needle, or similar object to

a qualified service person should

 

clean pilot. This can damage

service and repair heater.

 

pilot unit.

 

 

 

The two most common causes of a malfunctioning gas appliance are:

1.Loose wiring connections

2.Construction debris clogging the pilot and/or gas control valve filter

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Ignitor will not spark or pilot will not light

1.

No gas supply, or shutoff valve is OFF

1.

Check to see if you have gas supply and

 

 

 

 

that equipment shutoff valve is opened

 

2.

Air in gas line

2.

Repeat lighting procedure several times

 

 

 

 

to purge all air out of lines. If after re-

 

 

 

 

peated attempts appliance does not light,

 

 

 

 

call for qualified service and repair.

 

3.

Construction debris clogging pilot orifice

3.

Remove debris and dirt, inspect and

 

 

 

 

clean any other possible obstructions

 

4.

Low gas pressure

4.

Contact your gas supplier to check

 

 

 

 

pressure

 

5.

Kinked pilot line

5.

Have a qualified technician replace pi-

 

 

 

 

lot line

 

6.

Control valve knob is not opening

6.

Replace control valve (Refer to Replace-

 

 

 

 

ment Parts, page 29)

 

7.

No power to unit or the ignition module

7.

Check that main power is on and that all

 

 

or power transformer is bad

 

wire connections are made correctly to

 

 

 

 

the ignition model (see Wiring Diagram,

 

 

 

 

page 23). Check for 24 VAC at the sec-

 

 

 

 

ondary side of the transformer. If 24

 

 

 

 

VAC is present, and the module does not

 

 

 

 

oporate, have the module replaced oth-

 

 

 

 

erwise have the transformer replaced.

 

8.

Vent damper not fully open

8.

Open vent damper until fully locked in

 

 

 

 

OPEN position

 

 

 

 

 

Pilot will not stay lit

1.

Loose wiring on ignitor wire to ignition

 

 

module and/or poor ground to ignition

 

 

module

 

2.

Pilot flame too low to sense

1.Check wiring connection. Refer to wir- ing diagram (see Wiring Diagram, page

23)and/or check ground wire to igni- tion module

2.Clean and adjust pilot burner and check gas supply and inlet pressure to unit

Note: Have a qualified technician replace pilot assembly if broken or corroded

No gas to burner, although wall switch and

1.

Wall switch wires defective or too long

1.

Check electrical connections

valve are set to the ON position

 

 

 

 

 

 

 

 

 

Frequent pilot outage

1.

Pilot flame may be too low, causing

1.

Clean and adjust pilot flame for maximum

 

 

safety pilot to “drop out”

 

flame impingement on thermopile

 

2.

Improper venting or excessive blockage

2.

Have the vent system inspected, includ-

 

 

 

 

ing the termination cap. Remove any

 

 

 

 

restriction or obstruction

OBSERVED PROBLEMFor morePOSSIBLE CAUSEREMEDYment Parts, page 29)visit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

111924-01A

Image 27
Contents DIRECT-VENTFIREPLACE OWNER’S OPERATION AND INSTALLATION MANUALNATURAL GAS MODELS VK36EN SERIES PROPANE/LP GAS MODELS VK36EP SERIESSAFETY INFORMATION TABLE OF CONTENTSSAFETY INFORMATION PRODUCT IDENTIFICATIONLOCAL CODES ContinuedPRODUCT FEATURES PRE-INSTALLATION PREPARATIONLOCATION AND SPACE REQUIREMENTS FRAMING AND FINISHING PRE-INSTALLATION PREPARATIONContinued CLEARANCESLOCATION OF TERMINATION CAP LOCATION OF TERMINATION CAPD E B L V G V AINSTALLATION PRECAUTIONS VENTING INSTALLATION INSTRUCTIONSContinued VENTING INSTALLATION INSTRUCTIONSINSTALLATION PLANNING Horizontal Termination InstallationExterior VENTING INSTALLATION INSTRUCTIONSVENTING INSTALLATION INSTRUCTIONS ContinuedContinued VENTING INSTALLATION INSTRUCTIONSHorizontal Termination Configurations VENTING INSTALLATION INSTRUCTIONSVENTING INSTALLATION INSTRUCTIONS ContinuedRecommended Applications Venting with Two 90 Elbows VENTING INSTALLATION INSTRUCTIONSContinued Venting with Two 90 ElbowsContinued VENTING INSTALLATION INSTRUCTIONSINSTALLATION FOR VERTICAL TERMINATION Flat Ceiling InstallationVenting with Two 90 Elbows VENTING INSTALLATION INSTRUCTIONSVertical Termination Configurations ContinuedVertical Venting VENTING INSTALLATION INSTRUCTIONSHIGH ALTITUDE INSTALLATION ContinuedModel BK Installation FIREPLACE INSTALLATIONVENTING INSTALLATION INSTRUCTIONS PARTS LISTS FOR VENTING KITS AND COMPONENTSFIREPLACE INSTALLATION Model BKT InstallationContinued Continued FIREPLACE INSTALLATIONINSTALLING GAS PIPING TO FIREPLACE LOCATION Blower Wiring DiagramContinued FIREPLACE INSTALLATIONInstallation Items Needed Pressure Testing Gas Supply Piping SystemRemoving Louver Panels FIREPLACE INSTALLATIONPressure Testing Fireplace Gas Connections ContinuedContinued FIREPLACE INSTALLATIONCleaning Glass Door See Cleaning and Maintenance on pageContinued FIREPLACE INSTALLATIONINSTALLING LOGS, LAVA ROCK AND GLOWING EMBERS WALL SWITCH INSTALLATIONContinued WIRING DIAGRAMFIREPLACE INSTALLATION OPTIONAL REMOTE CONTROL INSTALLATION Model WRCTO TURN OFF GAS TO APPLIANCE OPERATING FIREPLACEFOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONSOPERATING FIREPLACE INSPECTING BURNERSOPERATING OPTIONAL BLOWER ACCESSORY PILOT ASSEMBLYLOGS CLEANING AND MAINTENANCEGLASS DOOR PILOT AND BURNERSREMEDY TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEPOSSIBLE CAUSE TROUBLESHOOTINGOBSERVED PROBLEM ContinuedSPECIFICATIONS REPLACEMENT PARTSSERVICE HINTS TECHNICAL SERVICEILLUSTRATED PARTS BREAKDOWN MODELS VK36EN, VK36ENH, VK36EP, VK36EPHILLUSTRATED PARTS BREAKDOWN PARTS LIST PARTS LISTILLUSTRATED PARTS BREAKDOWN PARTS LIST PARTS LIST111957-01 ACCESSORIES OWNERS REGISTRATION FORM Postage Required TAPETAPE Page WARRANTY INFORMATION LIMITED WARRANTY DIRECT-VENTFIREPLACENOT A UPC