Desa CGEFP33NR Operating Fireplace, Installing Screen, Installing Battery Into Remote

Page 20

UNVENTED NATURAL GAS FIREPLACE

INSTALLATION

Continued

INSTALLING SCREEN

WARNING: You must operate this fireplace with the fireplace screen in place. Make sure fire- place screen is in place before running fireplace.

Install fireplace screen by slipping notches of fireplace screen over screws on front of fireplace (see Figure 47).

Notches

Screws for Mounting Screen

Figure 47 - Installing Fireplace Screen

INSTALLING BATTERY INTO REMOTE

1.Locate slot at bottom of remote control (see Figure 48). Firmly insert tool such as a small screwdriver, butter knife, or dime into the slot and lift up to remove cover.

2.Insert supplied battery into remote control. Positive and negative are marked inside remote control casing. Note: Remote will not function if bat- tery is not installed correctly.

3.Slide tab on cover into remote housing and snap cover back into place.

Tab

OPERATING

FIREPLACE

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.

This appliance has a pilot which lights

 

automatically when using the sup-

 

plied wall switch or remote control.

 

If you have a power outage, the pilot

 

may be lighted by hand with push-

 

button piezo ignitor. When lighting

 

the pilot, the following warnings

 

must be followed.

B. BEFORE LIGHTING smell all

 

around the appliance area for gas. Be

 

sure to smell next to the floor because

 

some gas is heavier than air and will

 

settle on the floor.

 

WHAT TO DO IF YOU SMELL

 

GAS

 

Do not try to light any appliance.

 

Do not touch any electric switch;

 

 

do not use any phone in your building.

 

• Immediately call your gas supplier

 

 

from a neighbor’s phone. Follow

 

 

the gas supplier’s instructions.

 

If you cannot reach your gas sup-

 

 

plier, call the fire department.

C. Electric Power Outage Only: Use only

 

your hand to turn the manual over-

 

ride handle on the gas control knob.

 

Never use tools. If the knob will not

 

turn by hand, don’t try to repair it,

 

call a qualified service technician or

 

gas supplier. Force or attempted re-

NORMAL LIGHTING

INSTRUCTIONS

WARNING: You must operate this heater with the fireplace screen in place. Make sure fire- place screen is in place before running heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Open damper or window to vent smell. This will only last a few hours.

1.STOP! Read the safety information, in column 1.

2.Make sure equipment shutoff valve is fully open.

3.Wait five (5) minutes to clear out any gas. Smell for gas around heater and near floor. If you smell gas, STOP! Follow “B” in the safety information on warnings plate. If you don’t smell gas, go to the next step.

A. Using Supplied Wall Switch

1. Set manual ignition bypass switch on

the control panel to the OFF position

(automatic ignition position).

2. Press ON/OFF button. Hold for 6

seconds. Gas valve will open and elec-

tronic ignition will begin sparking to

light pilot. LED will light.

Note: You may be running this

heater for the first time after connect-

ing to gas supply or at the start of

your heating season. If so, the ON/

OFF button may need to be pressed

again. This will allow air to bleed

from gas system. If several attempts

to light pilot fail, contact a qualified

Slot

Cover

pair may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately

call a qualified service technician to

inspect the appliance and to replace

any part of the control system and

any gas control which has been un-

service person or gas supplier for re-

pairs. Until repairs are made, light

and operate manually (see Manual

Lighting Instructions for Electric

Power Outage, page 21).

3. When pilot flame is lit, the thermo-

couple is heated by the flame. When

thermocouple becomes hot (5 to 15

Remote

PositiveControl

Negative

Figure 48 - Installing Battery

der water.

seconds), main burner will automati-

cally light on high flame.

For more information, visit www.desatech.com

20

107569

Image 20
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information Unvented Natural GAS FireplaceUnpacking Product IdentificationLocal Codes Product Features AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation Installation ClearancesCheck GAS Type Electrical HookupRelocating Wall Switch Installation SequenceRemoval of Fireplace Screen and Floor Assembly Lines and wiring when moving floor Installing Variable Speed Blower Accessory Mounting Wall Switch to Side of MantelInstalling Plastic Bushing for Power Cord Operating the BlowerInstalling Thermostatic Blower Accessory Lower Rear Wall Firebox BlowerInstalling Bushings Left Side Exit shown Installation Items Needed Installing GAS Piping to Fireplace LocationConnecting Fireplace to GAS Supply Conventional Fireplace Installation Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Checking GAS ConnectionsBUILT-IN Fireplace Installation Actual Framing Height 32 3/8 Front Width DepthMantel Clearances for Built-In Installation Nails or Wood ScrewsInstalling Hood Installing Logs CGEFP33NRInstalling Logs EFP33NR Middle Log #1 Shaped Cutout in Base BurnerInstalling Screen Installing Battery Into RemoteFor Your Safety Read Before Lighting Operating FireplaceManual Lighting Instructions For Electrical Power Outage Using Hand-Held Wireless Remote ControlShutting Off Heater Wall Switch Shutting Off Heater Wireless Remote ControlShutting Off Heater When Manually Lit Inspecting BurnersOptional Blower Operation Pilot Flame PatternLogs Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Troubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement Wiring Diagram Specifications Replacement PartsService Hints Technical ServiceParts Dealers Illustrated Parts Breakdown Parts List Remote Control Fireplace EFP33NR and CGEFP33NRFirebox KEY Part Number Description QTY Accessories Blower Accessory GA3750 Series and GA3650T SeriesCorner Mantel Equipment Shutoff Valve GA5010Diameter Holes This page Intentionally Left Blank 107569 Warranty Information

CGEFP33NR specifications

Desa CGEFP33NR is an innovative and efficient electrical appliance designed to cater to modern household needs. At the forefront of its offering is its exceptional energy efficiency, which allows it to provide substantial heating power while minimizing energy consumption. This model is equipped with advanced heating technologies that ensure quick and consistent warmth throughout any space it occupies.

One of the standout features of the Desa CGEFP33NR is its dual-fuel capability. This versatile appliance can operate on both natural gas and propane, making it a flexible choice for various residential settings. Users can easily switch between fuel types based on availability or preference, ensuring that they have a dependable heating source regardless of external conditions.

The unit also boasts an impressive heat output of up to 33,000 BTUs, which is suitable for heating spaces up to 1,500 square feet. This powerful heating capability is complemented by a built-in thermostat that allows for precise temperature control, ensuring that users can maintain their desired comfort level. The adjustable flame settings further enhance user control, letting individuals customize the heat output according to their specific requirements.

In terms of design, the Desa CGEFP33NR features a sleek and modern aesthetic that fits seamlessly into any home decor. Its compact size allows for easy installation, and it can be mounted on the wall or used as a freestanding unit, providing flexibility in placement. Safety is a top priority with this appliance, featuring built-in safety mechanisms such as an automatic shut-off system that activates in case of any irregularities.

The Desa CGEFP33NR is also equipped with a robust ignition system that ensures reliable start-up during operation. With its durable construction and high-quality materials, this unit is built to withstand the rigors of daily use while providing long-lasting performance.

In conclusion, the Desa CGEFP33NR is a remarkable heating solution that combines efficiency, versatility, and modern design. Its range of features, including dual-fuel capability, adjustable heat settings, and safety mechanisms, make it an ideal choice for homeowners looking to enhance their living spaces with effective and reliable heating solutions while also being energy-conscious.