INSTALLING
Continued
A.G.A.
With 1/8" NPT Tap*
Approved
Flexible
Gas Line
|
| From Gas Meter | |
3" Minimum | (5" W.C. to 10.5" W.C. | ||
| Pressure) | ||
|
| ||
|
|
| Sediment |
|
| Tee Joint | Trap |
|
|
| |
|
| Pipe Nipple |
|
Figure 16 - Gas Connection | Cap |
| |
|
|
*Purchase the optional A.G.A.
CONNECTING FIREPLACE TO GAS SUPPLY
Installation Items Needed
•5/16" hex socket wrench or
•Phillips screwdriver
•sealant (resistant to propane gas, not provided)
1.Remove fireplace screen. Remove two screws that hold fireplace screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove.
2.Remove access door from rear or side of fireplace. See Product Identification, page 4, for access door locations.
3.Remove screws that attach log base assembly to fireplace (see Figure 17). Carefully lift up log base assembly and remove from fireplace (see Figure 17).
CAUTION
WARNING ICON | G 001 |
Do not pick up log base assembly by burners. This could damage burners. Only handle base by grates.
Continued
Figure 17 - Removing Log Base Assembly From Fireplace | 17 |
101742