Desa UNVENTED (VENT-FREE) NATURAL GAS FIREPLACE Trouble- Shooting, Continued, Cleaning and Mainte

Page 27
TROUBLE- SHOOTING

TROUBLE- SHOOTING

OBSERVED

POSSIBLE

 

PROBLEM

CAUSE

REMEDY

 

 

 

Continued

When ignitor button is pressed, there is spark at ODS/pilot but no ignition

1.Gas supply turned off or manual shutoff valve closed

2.Control knob not in PILOT position

3.Control knob not pressed in while in PILOT position

4.Air in gas lines when installed

5.ODS/pilot is clogged

6.Gas regulator setting is not correct

1.Turn on gas supply or open manual shutoff valve

2.Turn control knob to PILOT position

3.Press in control knob while in PILOT position

4.Continue holding down control knob. Repeat igniting operation until air is removed

5.Clean ODS/pilot (see Cleaning and Mainte- nance, page 26) or replace ODS/pilot assembly

6.Replace gas regulator

ODS/pilot lights but

1.

Control knob not fully

1.

Press in control knob

flame goes out when

 

pressed in

 

fully

control knob is

2.

Control knob not

2.

After ODS/pilot lights,

released

 

pressed in long enough

 

keep control knob

 

 

 

 

pressed in 30 seconds

 

3.

Safety interlock system

3.

Wait one minute for

 

 

has been triggered

 

safety interlock system

 

 

 

 

to reset. Repeat ignition

 

 

 

 

operation

 

4.

Manual shutoff valve

4.

Fully open manual shut-

 

 

not fully open

 

off valve

 

5.

Thermocouple connec-

5.

Hand tighten until snug,

 

 

tion loose at control

 

then tighten 1/4 turn

 

 

valve

 

more

 

6.

Pilot flame not touching

6.

A) Contact local natural

 

 

thermocouple, which

 

gas company

 

 

allows thermocouple to

 

 

 

 

cool, causing pilot flame

 

B) Clean ODS/pilot (see

 

 

to go out. This problem

 

Cleaning and Mainte-

 

 

could be caused by one

 

nance, page 26) or

 

 

or both of the following:

 

replace ODS/pilot

 

 

A) Low gas pressure

 

assembly

 

 

B) Dirty or partially

 

 

 

 

clogged ODS/pilot

 

 

 

7.

Thermocouple damaged

7.

Replace thermocouple

 

8.

Control valve damaged

8.

Replace control valve

Continued

101742

27

Image 27
Contents OWNER’S OPERATION AND INSTALLATION MANUAL Save this manual for future referenceUNVENTED VENT-FREENATURAL GAS FIREPLACE Safety Information continues on next page CONTENTS SAFETY INFORMATIONWARNINGS DANGERSAFETY INFORMATIONContinued PRODUCT IDENTIFICATION Figure 1 - Log Base AssemblyFigure 2 - Fireplace Piezo Ignition System LOCAL CODES UNPACKING PRODUCT FEATURESSafety Device OperationPROVIDING ADEQUATE VENTILATION AIR FOR COMBUSTION AND VENTILATIONContinued AIR FORVENTILATION COMBUSTIONVentilation Air from Inside Building AIR FOR COMBUSTION AND VENTILATIONContinued VENTILATION AIRINSTALLING NOTICEContinued INSTALLING ContinuedASSEMBLING AND ATTACHING BRASS TRIM CONVENTIONAL FIREPLACE INSTALLATION INSTALLINGINSTALLATION CLEARANCES ContinuedINSTALLING Continuedheads and putty over Continued INSTALLINGBUILT-INFIREPLACE INSTALLATION Continued39 3/8 27 7/8 35 1/2 55 5/8 INSTALLINGFigure 13 - Attaching Nailing Flange Accessory ContinuedContinued INSTALLINGMantel Clearances for Built-InInstallation ContinuedNOTICE INSTALLINGINSTALLING GAS PIPING TO FIREPLACE LOCATION Installation Items NeededContinued INSTALLINGCONNECTING FIREPLACE TO GAS SUPPLY Installation Items NeededContinued G 001WARNINGINSTALLING NOTICEContinued INSTALLINGPressure Testing Fireplace Gas Connections ContinuedFigure 22 - Installing Front Log INSTALLINGINSTALLING LOGS Figure 21 - Installing Rear LogContinued INSTALLINGFigure 23 - Installing Crossover Log ContinuedContinued FOR YOUR SAFETY READ BEFORE LIGHTINGOPERATING FIREPLACE INSTALLINGLIGHTING INSTRUCTIONS OPERATINGFIREPLACE NOTICEOPERATING FIREPLACE MANUAL LIGHTING PROCEDURETO TURN OFF GAS TO APPLIANCE VARIABLE OUTPUT CONTROL OPERATIONPILOT FLAME PATTERN INSPECTINGBURNERS NOTICECLEANING AND MAINTENANCE TROUBLE SHOOTING ODS/PILOT AND BURNERSLOGS Continued TROUBLE- SHOOTINGCleaning and Mainte ContinuedCleaning and Mainte TROUBLE SHOOTINGCleaning and Mainte Cleaning and Mainteleaks see Checking Gas TROUBLESHOOTING ContinuedWhen gas quality is bad TECHNICAL SERVICE SERVICE HINTSREPLACEMENT PARTS SPECIFICATIONS When gas pressure is too lowHEARTH BASE GC3333F- Walnut Finished ACCESSORIESCABINET MANTEL GMC11F - Walnut Finished GMC12U - UnfinishedBREAKDOWN Log Base AssemblyILLUSTRATED PARTSDESCRIPTION PARTS LISTLog Base Assembly PART NUMBERBREAKDOWN FireplaceILLUSTRATED PARTSDESCRIPTION PARTS LISTFireplace PART NUMBERWARRANTY INFORMATION LIMITED WARRANTY VENT-FREENATURAL GAS FIREPLACEKEEP THIS WARRANTY