Continental CDIZC - N, CDIZC - P manual Replacement Blower Installation

Page 10

10

REPLACEMENT BLOWER INSTALLATION

The Napoleon gas fireplace insert comes standard with a blower, a heat sensor, variable on/off speed control and a power cord. Because the blower is thermally activated, when turned on, it will automatically start approximately 15 minutes after lighting the fireplace and will run for approxi- mately 30 minutes after the fireplace has been turned off. Use of the fan increases the output of heat. Air, drawn in through the lower slot, is driven up the back of the firebox, and exhausted as hot air through the upper slot.

black

red

 

white

THERMODISC

 

B R A C K E T

BLOWER

ASSEMBLY

WIRES

 

FIGURE 24

4.Disconnect the two blower wires. Remove the blower bracket secured with one wing nut and lock washer.

For thermodisc replacement: Remove the "Z" shaped mounting bracket secured to the firebox wall to the left of the blower. Remove the thermodisc from the bracket and replace.

FIGURE 21

1.Turn off the electrical power and the gas supply to the fireplace insert.

2.Remove the fire viewing door. Remove the logs.

FIGURE 22

B

A

FIGURE 25

C

FIGURE 26

3.Detach the two screws from the back of the firebox and remove the panel, as illustrated.

BLOWER ACCESS DOOR

5.Replace the blower using the existing bracket. Slide the vibration reducing pad (A) into the clip (C) and up against the threaded stud (B) at the other end. The blower must be able to be positioned entirely onto the pad.

Slide the blower into the clip (C). Secure to the threaded stud using the existing lock washer and wing nut. Ensure that the blower does not touch the fireplace base or the firebox.

6.Reconnect the two wires. Holding the replacement gas- ket in place, reattach the blower access door and panel. Replace the logs. Re-install the fire viewing door.

7.Turn the gas supply and electricity back on.

Drywall dust will penetrate into the blower bearings caus- ing irreparable damage and must be prevented from coming into contact with the blower or its compartment. Any damage resulting from this condition is not cov- ered by the warranty policy.

FIGURE 23

4.Remove the blower access door held on with the re- maining 8 screws. Replace the blower access door gas- ket when changing the blower.

W415-0224 / D / 01.15.04

Image 10
Contents GAS-FIRED Direct Vent Insert Table of Contents Conditions and Limitations General Information General InstructionsCare of GLASS, and Plated Parts Sided Backer Plate Front View InstallationSided Backer Plates Side Views TOP View Insert Vent Connection Chimney ConnectionFinishing Logo Placement LOG PlacementDoor Installation Mantle ClearanceOperating Instructions Operation / MaintenanceMaintenance Purge the GAS Line with the Glass Door OpenReplacement Blower Installation Venturi Adjustment AdjustmentsPilot Burner Adjustment Vent RestrictionReplacements W415-0224 / D Trouble Shooting Guide Symptom Problem Test SolutionRefer to Main Burner Goes OUT Pilot Stays on Fireplace Service History