WALL SWITCH / THERMOSTAT

For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient location. Route 2-strand solid core millivolt wire from the gas fireplace insert to the wall switch / millivolt ther- mostat. The recommended maximum lead length de- pends on the wire size:

7

GAS INSTALLATION

Install suitable supply piping connection to the 3/8" flex connector supplied (as per local gas codes).

FIGURE 6

WIRE SIZE

MAX. LENGTH

14gauge

100 feet

16gauge

60 feet

18gauge

40 feet

Do not connect either the wall switch, thermo- stat or gas valve to electricity (110 VOLTS).

The insert may now be pushed into its final posi- tion inside the wood-burn- ing fireplace. Secure the in- sert to the fireplace using perforated strapping at- tached to the two securing holes on either side of the unit as shown. We recom- mend that the trim be in- stalled before the unit is placed into its final position.

S E C U R I N G

HOLES

FIGURE 7

FINISHING

In order to close off the fireplace opening or if the opening is larger than the 3- or 4-sided aluminium extrusion trim kits, it is recommended to reduce the opening using a non- combustible material such as ceramic tile, marble, etc or the GIZBP6-3or GIZBP6-4backer plate kits. The outside edge of the backer plate is finished off with gold trim in- cluded in each kit. A deluxe flashing kit complete with mar- quis trim may also be used to complete the installation. These flashing and trim combinations are available in 6 and 9 inch widths as well as many finishes to accent any room decor. Mounting brackets, GIZBRKT, are required to install the deluxe flashing. Detailed installation instructions are included with each kit.

If this unit is being installed into an existing wood burning, zero clearance fireplace, then be aware of this precaution:

Any circulation air opening may be covered (with non- combustible material) but not sealed!

ALUMINIUM EXTRUSION TRIM KIT

INSTALLATION

The insert can be equipped with either a 3- or 4-sided trim kit to finish off the fire- place opening. Slide the trim assembly over the keyholes (2 per side) and drop into place. If installing the op- tional 3- or 4-sided backer plate (GIZBP6-3or GIZBP6- 4), it must be hung prior to the trim kit installation us-

ing the same keyholes.

FIGURE 9

FIRE VIEWING DOOR

VALVE

CONTROL

DOOR

 

FIGURE 8

FIGURE 10

SLIDE TO FIGURE 11

 

 

ADJUST

 

LOOSEN

 

SCREWS

To adjust the trim: If the mitre is out of alignment, open each side and loosen the two screws at either side trim hinge. Slide the trim up or down to adjust and re-tighten screws. There is also a very slight in/out adjustment that can be made.

Note: Since the side panels open and close, to access the controls, a gap is necessary at the mitre joint.

The top trim piece has an adjustable securing bracket which enables the trim to be secured to the firebox shell.

W415-0224 / D / 01.15.04

Image 7
Contents GAS-FIRED Direct Vent Insert Table of Contents Conditions and Limitations General Information General InstructionsCare of GLASS, and Plated Parts Sided Backer Plate Front View InstallationSided Backer Plates Side Views TOP View Chimney Connection Insert Vent ConnectionFinishing Mantle Clearance LOG PlacementDoor Installation Logo PlacementPurge the GAS Line with the Glass Door Open Operation / MaintenanceMaintenance Operating InstructionsReplacement Blower Installation Vent Restriction AdjustmentsPilot Burner Adjustment Venturi AdjustmentReplacements W415-0224 / D Symptom Problem Test Solution Trouble Shooting GuideRefer to Main Burner Goes OUT Pilot Stays on Fireplace Service History