ADJUSTMENTS

PILOT BURNER ADJUSTMENT

Remove the pilot screw cap. Adjust the pilot screw to pro- vide properly sized flame. Turn in a clockwise direction to reduce the gas flow. Replace the pilot screw cap.

FIGURE 27

FIGURE 28

VENT RESTRICTION

Some vent configurations may display a very active flame. If this appearance is not desirable, the vent exit may be re- stricted using the restrictor plate shown in FIGURE 6b. Bend the flap up as shown to reduce the velocity of the exhaust gases, slowing down the flame pattern and creating a more traditional appearance.

VENTURI ADJUSTMENT

This unit is approved for use with a 2" liner for air intake and a 3" liner for exhaust. For best performance, however, it is recommended to use two 3" liners.

Air shutter settings will differ depending on the liner sys- tem used. Use the charts below to determine the correct air shutter setting:

 

3"/3"LINERSYSTEM

NG

1/16"

LP

3/16"

 

AIR SHUTTER SETTING

 

 

 

 

 

2"/3"LINERSYSTEM

NG

1/8"

LP

5/16"

 

AIR SHUTTER SETTING

Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports. The flame may not appear yellow immediately; allow 15 to 30 minutes for the final flame colour to be estab- lished.

Air shutter adjustment must only be done by a qualified gas installer!

FIGURE 30

HELPFUL HINT:

A mirror will let you see the opening of the air shutter without removing the burner. Scribe a line along the venturi tube and air shutter cap. Open or close according to the original opening by using the scribed line as your datum.

FIGURE 29

W415-0224 / D / 01.15.04

Image 11
Contents GAS-FIRED Direct Vent Insert Table of Contents Conditions and Limitations Care of GLASS, and Plated Parts General InstructionsGeneral Information Sided Backer Plates Side Views TOP View InstallationSided Backer Plate Front View Chimney Connection Insert Vent ConnectionFinishing Mantle Clearance LOG PlacementDoor Installation Logo PlacementPurge the GAS Line with the Glass Door Open Operation / MaintenanceMaintenance Operating InstructionsReplacement Blower Installation Vent Restriction AdjustmentsPilot Burner Adjustment Venturi AdjustmentReplacements W415-0224 / D Symptom Problem Test Solution Trouble Shooting GuideRefer to Main Burner Goes OUT Pilot Stays on Fireplace Service History