Continental CDIZC - N manual LOG Placement, Door Installation, Mantle Clearance, Logo Placement

Page 8

8

LOG PLACEMENT

Positioning the logs improperly will cause flame im- pingement and carboning.

PHAZERTM logs and glowing embers, exclusive to Continental Fireplaces, glow when exposed to direct flame and provide a unique and realistic glowing effect that is different in every installation. Take the time to carefully position the glowing embers for a maximum glowing effect. Use only certified PHAZERTM logs available from your Continental / Wolf Steel Ltd. dealer.

1.Place the rear log (#1) onto the two log supports and against the air intake pipe.

FIGURE 12

#1

DOOR INSTALLATION

Place the door into the two lower door brackets, and se- cure at the top of the unit with two #10-24 machine screws.

FIGURE 16

LOWER DOOR BRACKET

2.Position logs #2 and #3 against the grate posts and line up the studs located on the burner with the holes on the bottom of the logs. Keep slightly back of the front row of ports.

FIGURE 13

#2

#3

3.Fit the centre log (#4) into place behind log #3 and into the pocket provided on the back log.

FIGURE 14

#4

FIGURE 15

GLOWING EMBERS

MANTLE CLEARANCE

This can vary according to the mantle depth. Use the graph to help evaluate the clearance needed.

FIGURE 17

M H

A E

N I

T G

L H

E T

MANTLE WIDTH

LOGO PLACEMENT

Remove the backing of the logo supplied and place on the glass viewing door, as indicated.

4. Tear the glowing embers into pieces and place along

 

 

 

 

 

the front row of ports covering all of the burner area in front

 

 

 

 

 

of the logs. Care should be taken to shred the embers into

 

 

 

 

 

thin, small irregular pieces as only the exposed edges of

 

 

 

 

 

the fibre hairs will glow. The ember material will only glow

½”

 

 

when exposed to direct flame; however, care should be

 

 

 

taken to not block the burner ports. Blocked burner ports

 

 

 

 

 

 

 

 

 

 

can cause an incorrect flame pattern, carbon deposits and

 

 

 

 

 

delayed ignition.

 

 

 

 

 

Log colours may vary. During the initial use of the fireplace,

 

 

 

 

 

the colours will become more uniform as colour pigments

FIGURE 18

burn in during the heat activated curing process.

LOGO

½”

W415-0224 / D / 01.15.04

Image 8
Contents GAS-FIRED Direct Vent Insert Table of Contents Conditions and Limitations Care of GLASS, and Plated Parts General InstructionsGeneral Information Sided Backer Plates Side Views TOP View InstallationSided Backer Plate Front View Insert Vent Connection Chimney ConnectionFinishing LOG Placement Door InstallationLogo Placement Mantle ClearanceOperation / Maintenance MaintenanceOperating Instructions Purge the GAS Line with the Glass Door OpenReplacement Blower Installation Adjustments Pilot Burner AdjustmentVenturi Adjustment Vent RestrictionReplacements W415-0224 / D Trouble Shooting Guide Symptom Problem Test SolutionRefer to Main Burner Goes OUT Pilot Stays on Fireplace Service History