Continental CDIZC - P, CDIZC - N manual Installation, Sided Backer Plate Front View

Page 5

5

INSTALLATION

Provide adequate ventilation air.

Provide adequate accessibility clearance for servicing and operating the fireplace insert.

Never obstruct the front opening of the fire- place insert.

Objects placed in front of the fireplace must be kept a minimum of 48" away from the front face of the unit.

FIGURES1a-c

3 SIDED BACKER PLATE - FRONT VIEW

Clean out ashes from the inside of the wood-burning fire- place. Make sure that the chimney and wood-burning fire- place are in a clean and sound condition and constructed of non-combustible materials. If necessary have any re- pair work done by a qualified person before installing the insert. Remove the existing fireplace damper or lock into an open position.

Using screws, attach the fireplace warning tag (W385-0199) to the inside of the firebox of the fireplace into which the insert is being installed.

WARNING: THIS FIREPLACE HAS BEEN CONVERTED FOR USE WITH A GAS FIREPLACE INSERT ONLY AND CANNOT BE USED FOR BURNING WOOD OR SOLID FUELS UNLESS ALL ORIGINAL PARTS HAVE BEEN REPLACED AND THE FIREPLACE IS RE-APPROVED BY THE AUTHORITY HAVING JURISDICTION.

ATTENTION: CE FOYER A ETE CONVERTI AFIN D'ETRE UTILISE SEULEMENT COMME FOYER ENCASTRE AU GAZ ET NE PEUT ETRE UTILSE POUR BRULER DU BOIS OU TOUT AUTRE COMBUSTIBLE SOLIDE, SANS QUE TOUTES LES PIECES ORIGINALES AIENT ETE REMPLACEES ET QUE LE FOYER SOIT APPROUVE DE NOUVEAU PAR

LES AUTORITES AYANT JURIDICTION.

W385-0199

The sheet-metal parts of the fireplace, in which the gas fireplace insert is to be installed, must not be cut.

If the wood-burning factory-built fireplace has no gas access hole(s) provided, an access hole of 1½ inch or less may be drilled through the lower sides or bottom of the fireplace in a proper workman like manner. This access hole must be plugged with non-combustible in- sulation after the gas supply line has been installed.

Ensure that existing chimney cleanouts fit properly.

The refractory, glass doors, screen rails, screen mesh and log grates may be removed from the fireplace be- fore installing the gas fireplace insert.

Smoke shelves, shields and baffles may be removed if attached by mechanical fasteners.

The ventilation openings in the fireplace may be ob- structed by the backer plates, aluminium trim etc. but these parts are not to be applied so as to have an air- tight seal.

3 & 4 SIDED BACKER PLATES - SIDE VIEWS

TOP VIEW

4 SIDED BACKER PLATE - FRONT VIEW

W415-0224 / D / 01.15.04

Image 5
Contents GAS-FIRED Direct Vent Insert Table of Contents Conditions and Limitations Care of GLASS, and Plated Parts General InstructionsGeneral Information Sided Backer Plates Side Views TOP View InstallationSided Backer Plate Front View Chimney Connection Insert Vent ConnectionFinishing Door Installation LOG PlacementLogo Placement Mantle ClearanceMaintenance Operation / MaintenanceOperating Instructions Purge the GAS Line with the Glass Door OpenReplacement Blower Installation Pilot Burner Adjustment AdjustmentsVenturi Adjustment Vent RestrictionReplacements W415-0224 / D Symptom Problem Test Solution Trouble Shooting GuideRefer to Main Burner Goes OUT Pilot Stays on Fireplace Service History