Vermont Casting DVT38 installation instructions General Venting Information Termination Location

Page 10

Chateau™

General Venting Information - Termination Location

D

V

E

L

V

B

C

V�����

������

F

V

��������

 

B

 

INSIDE

 

 

CORNER DETAIL

 

 

G

 

 

V

 

A

H

N

 

B

 

B

V

 

V

 

 

��������

�����

 

 

 

������

 

 

 

 

 

 

B

V J X

B

M

 

N

G

G

V

A

I

 

V KX

V

A

 

 

V VENT TERMINATION X AIR SUPPLY INLET

AREA WHERE TERMINAL IS NOT PERMITTED

 

CFM145a

 

 

 

 

 

 

 

Canadian Installations1

US Installations2

 

 

A =

Clearance above grade, veranda, porch,

12” (30cm)

 

12” (30cm)

 

 

deck, or balcony

 

 

 

 

 

B = Clearance to window or door that may be

6” (15cm) for appliances

6” (15cm) for appliances

 

 

opened

< 10,000Btuh (3kW), 12” (30cm)

< 10,000 Btuh (3kW), 9”

 

 

 

for appliances > 10,000 Btuh (3kW) and

(23cm) for appliances > 10,000

 

 

 

< 100,000 Btuh (30kW), 36” (91cm)

Btuh (3kW) and < 50,000 Btuh

 

 

 

for appliances > 100,000 Btuh (30kW)

(15kW), 12” (30cm) for

 

 

 

 

 

appliances > 50,000 Btuh (15kW)

 

C = Clearance to permanently closed window

12” (305mm) recommended to

12” (305mm) recommended to

 

 

 

prevent window condensation

prevent window condensation

 

D = Vertical clearance to ventilated soffit located

 

 

 

 

 

 

above the terminal within a horizontal

18” (458mm)

 

18” (458mm)

 

 

distance of 2 feet (610mm) from the center

*Clearances to soffit do not apply

to “vinyl soffits”.

 

 

line of the terminal

 

 

 

 

 

 

 

E = Clearance to unventilated soffit

12” (305mm)

 

12” (305mm)

 

F =

Clearance to outside corner

see next page

 

see next page

 

G = Clearance to inside corner (see next page)

see next page

 

see next page

 

H = Clearance to each inside of center line

3ʼ (91cm) within a height of 15ʼ

3ʼ (91cm) within a height of 15ʼ

 

 

extended above meter/regulator assembly

above the meter/regulator assembly

above the meter/regulator assy

 

I =

Clearance to service regulator vent outlet

3ʼ (91cm)

 

3ʼ (91cm)

 

J =

Clearance to nonmechanical air supply inlet

6” (15cm) for appliances < 10,000

6” (15cm) for appliances

 

 

to building or the combustion air inlet to any

Btuh (3kW), 12” (30cm) for

< 10,000 Btuh (3kW), 9”

 

 

other appliances

appliances > 10,000 Btuh (3kW) and <

(23cm) for appliances > 10,000

 

 

 

100,000 Btuh (30kW), 36” (91cm)

Btuh (3kW) and < 50,000 Btuh

 

 

 

for appliances > 100,000 Btuh (30kW)

(15kW), 12” (30cm) for

 

 

 

 

 

appliances > 50,000 Btuh (15kW)

 

K =

Clearance to a mechanical air supply inlet

6ʼ (1.83m)

 

3ʼ (91cm) above if within 10ʼ

 

 

 

 

 

(3m) horizontally

 

L =

Clearance above paved sidewalk or paved

7ʼ (2.13m)†

 

7ʼ (2.13m)†

 

 

driveway located on public property

 

 

 

 

 

M = Clearance under veranda, porch, deck or

12” (30cm)

 

12” (30cm)

 

 

balcony

 

 

 

 

N = Clearance above a roof shall extend a minimum of 24” (610mm) above the highest point when it passes through the roof surface, and any other obstruction within a horizontal distance of 18” (450mm).

1 In accordance with the current CSA-B149 Installation Codes

2 In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Codes

A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwell ings

‡ only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor: NOTE: 1. Local codes or regulations may require different clearances.

2.The special venting system used on CFM Specialty Home Products Direct Vent Fireplaces are certified as part of the appliance,

with clearances tested and approved by the listing agency.

Fig. 12 Vent termination clearances.

Image 10
Contents INSTALLER/CONSUMER Safety Information What to do if YOU Smell GASTable of Contents Locating Your Fireplace Installation & Operating InstructionsPlease Review the Following Carefully Fireplace Dimensions DVT38 Clearance to Combustibles MantelsFraming and Finishing Nailing flangesGas Inlet and Manifold Pressures Gas Line InstallationFinal Finishing Gas SpecificationsElectrical Junction Box E Units Only Remote ON/OFF SwitchElectronic Gas Control Valve General Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationQuick Reference for Fresh Air Restrictor Plate / Flue Baffle General Information Assembling Vent Pipes SK8 Venting Pipes Canadian InstallationsUSA Installations Horizontal TerminationDVT44 only Sidewall ApplicationsDVT38 only Sidewall Installation StepAlways install horizontal venting on a level plane Locate vent opening on wallFresh Air Restrictor Plate Vertical Through-the-Roof Installation Typical offset applicationMin 610mm Chimney Components Component Description Model NumberRestrictor Plates Installation Glass Information Glass CleaningGlass Frame Assembly Removal Operating InstructionsCeramic Refractory Installation Fresh Air Restrictor Plate AdjustmentLog, Lava Rock and Ember Placement Place log rear onto rear log bracket Flame Characteristics Flame & Temperature AdjustmentRN/RP & EN/EP Models Lighting And Operating Instructions To Turn Off Gas To HeaterTurning Off the Gas to the Appliance Lighting and Operating InstructionsLighting Instructions Valve in the on positionTroubleshooting the Gas Control System SIT Nova 820 Millivolt ValveSIT 822 Valve with a Honeywell Electronic Ignitor Conversion Procedure Conversion PrecautionsFuel Conversion Instructions Pilot Flame Adjustment Remove valve regulatorInjector Orifice Size Matrix Cleaning Electronic Ignition System MaintenanceCleaning the Standing Pilot Control System Battery Replacement for Ignitor ModuleDVT38, DVT44 DVT38, DVT44 DVT38 DVT44Fuel Conversion Kits Full Surround Mantel AccessoriesRemote Controls Model Functions ControlledChateau Chateau Product Covered by this Warranty If Warranty Service is NEEDED…Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %

DVT38 specifications

The Vermont Casting DVT38 is a standout model in the realm of contemporary gas fireplaces, epitomizing both innovative engineering and aesthetic elegance. Designed with a focus on efficiency and style, the DVT38 offers homeowners an exceptional heating experience while enhancing the ambiance of their living spaces.

One of the main features of the Vermont Casting DVT38 is its impressive heat output. With a BTU range that ensures warmth for larger areas, the fireplace is capable of efficiently heating spaces without consuming excessive fuel. This is a critical aspect for homeowners seeking both comfort and energy savings. The fireplace integrates a dual burner system, promoting a uniform heat distribution and ensuring that every corner of the room enjoys consistent warmth.

Another notable characteristic of the DVT38 is its advanced burner technology. The unique burner design allows for a natural gas or propane option, giving consumers flexibility based on availability and preference. The adjustable flame settings enable users to customize the heat output and ambiance, perfect for both cozy winter evenings and social gatherings.

In terms of aesthetics, the Vermont Casting DVT38 boasts a sophisticated design that complements various interior styles. It features large glass viewing areas which present a captivating flame pattern, enhancing the visual appeal of the unit. The contemporary facade can be finished with a variety of trims and options, allowing homeowners to tailor the fireplace to their personal décor.

The DVT38 is also equipped with an easy-to-use electronic ignition system, further simplifying the operation. This feature ensures that lighting the fireplace is hassle-free, eliminating the need for matches or manual lighting. Additionally, many models come with a remote control option, allowing users to adjust settings from a distance, thereby enhancing convenience and usability.

Moreover, the DVT38 is built with durability in mind, incorporating high-quality materials that withstand the test of time while providing a reliable heating solution. Vermont Castings is renowned for its commitment to craftsmanship, and this model exemplifies that ethos.

In summary, the Vermont Casting DVT38 is an exquisite blend of functionality and design. With efficient heating capabilities, cutting-edge technology, and customizable aesthetics, it stands out as a premier choice for anyone looking to elevate their home heating experience. Whether for warmth or ambiance, the DVT38 is engineered to deliver satisfaction for years to come.