Troubleshooting the Gas Control System

SIT 822 Valve with a Honeywell Electronic Ignitor

START

Turn Gas Supply Off

Turn On/Off Switch To Call For Heat "on"

Power To Module

(24V Normal)

YES

Spark Across

Ignitor Sensor Gap

YES

Turn Gas On Pilot Burner Lights?

YES

Spark Stops When

Pilot Is Lit?

YES

Main Burner Lights?

YES

System Runs Until

On/Off Switch Is In

"Off" Position

YES

Troubleshooting

Ends

NO

Check: • Line Voltage (120vac)

 

 

• Low Voltage Transformer

 

 

 

 

(19.5 Minimum Vac)

 

 

• On/off Switch

 

 

• Wiring Connections

 

 

Unplug Ignition Lead

 

NO

 

NO

and Check Spark

 

• Replace Module

 

 

 

 

At Module

 

 

 

 

 

(24Vac Normal)

 

 

 

 

 

Spark OK?

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

Check Ignition Cable Ground Wiring, Ceramic Insulator And Gap. Correct As Necessary

Check Boot Of Ignition Cable For Signs Of Melting Or Buckling. Take Protective Action To Shield

Cable And Boot From Excessive Temperatures.

NO

• Check That All Manual Gas Valves Are Open, Supply Tubing

 

 

 

 

And Pressures Are Good, And Pilot Burner Orifice

 

 

Is Not Blocked.

 

 

• Check Electrical Connections Between Module And

 

 

Pilot Operator On Gas Control.

 

 

• Check For 24vac Across Pv-mvpv Terminals On Module If

 

 

Voltage Is Okay, Replace Gas Control If Not, Replace

 

 

Module.

NO

NOTE: If S8600B Goes Into Lockout, Reset System.

 

 

Check Continuity Of Ignition Cable And Ground Wire.

Clean Flame Rod

Check Electrical Connections Between Flame Rod & Module.

Check For Cracked Ceramic Flame Rod Insulator.

Check That Pilot Flame Covers Flame Rod And Is Steady Blue

Adjust Pilot Flame.

If Problem Persists, Replace Module.

NO

• Check For 24vac Across Mv-mvpv Terminals If No

Voltage, Replace Module.

 

 

 

 

• Check Electrical Connections Between Module And Gas

 

 

 

 

Control. If Okay, Replace Gas Control, Or Gas Control

 

 

Operator.

NO

NOTE: If S8600B Goes Into Lockout, Reset System

Check For Continuity Of Ignition Cable And Ground Wire. Note: If Ground Is Poor Or Erratic, Shutdown May Occur Occasionally Even Though Operation Is Normal At The Time Of Checkout.

Check That The Pilot Flame Covers Flame Rod And Is Steady And Blue.

If Checks Are Okay, Replace Module.

28

20006081

Image 28
Contents INSTALLER/CONSUMER Safety Information What to do if YOU Smell GASTable of Contents Locating Your Fireplace Installation & Operating InstructionsPlease Review the Following Carefully Fireplace Dimensions DVT38 Clearance to Combustibles MantelsFraming and Finishing Nailing flangesGas Line Installation Final FinishingGas Inlet and Manifold Pressures Gas SpecificationsElectrical Junction Box E Units Only Remote ON/OFF SwitchElectronic Gas Control Valve General Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationQuick Reference for Fresh Air Restrictor Plate / Flue Baffle Canadian Installations USA InstallationsGeneral Information Assembling Vent Pipes SK8 Venting Pipes Horizontal TerminationDVT44 only Sidewall ApplicationsDVT38 only Sidewall Installation StepAlways install horizontal venting on a level plane Locate vent opening on wallFresh Air Restrictor Plate Vertical Through-the-Roof Installation Typical offset applicationMin 610mm Chimney Components Component Description Model NumberGlass Information Glass Cleaning Glass Frame Assembly RemovalRestrictor Plates Installation Operating InstructionsCeramic Refractory Installation Fresh Air Restrictor Plate AdjustmentLog, Lava Rock and Ember Placement Place log rear onto rear log bracket Flame Characteristics Flame & Temperature AdjustmentRN/RP & EN/EP Models Lighting And Operating Instructions To Turn Off Gas To HeaterLighting and Operating Instructions Lighting InstructionsTurning Off the Gas to the Appliance Valve in the on positionTroubleshooting the Gas Control System SIT Nova 820 Millivolt ValveSIT 822 Valve with a Honeywell Electronic Ignitor Conversion Procedure Conversion PrecautionsFuel Conversion Instructions Pilot Flame Adjustment Remove valve regulatorInjector Orifice Size Matrix Maintenance Cleaning the Standing Pilot Control SystemCleaning Electronic Ignition System Battery Replacement for Ignitor ModuleDVT38, DVT44 DVT38, DVT44 DVT38 DVT44Fuel Conversion Kits Accessories Remote ControlsFull Surround Mantel Model Functions ControlledChateau Chateau Product Covered by this Warranty If Warranty Service is NEEDED…Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %

DVT38 specifications

The Vermont Casting DVT38 is a standout model in the realm of contemporary gas fireplaces, epitomizing both innovative engineering and aesthetic elegance. Designed with a focus on efficiency and style, the DVT38 offers homeowners an exceptional heating experience while enhancing the ambiance of their living spaces.

One of the main features of the Vermont Casting DVT38 is its impressive heat output. With a BTU range that ensures warmth for larger areas, the fireplace is capable of efficiently heating spaces without consuming excessive fuel. This is a critical aspect for homeowners seeking both comfort and energy savings. The fireplace integrates a dual burner system, promoting a uniform heat distribution and ensuring that every corner of the room enjoys consistent warmth.

Another notable characteristic of the DVT38 is its advanced burner technology. The unique burner design allows for a natural gas or propane option, giving consumers flexibility based on availability and preference. The adjustable flame settings enable users to customize the heat output and ambiance, perfect for both cozy winter evenings and social gatherings.

In terms of aesthetics, the Vermont Casting DVT38 boasts a sophisticated design that complements various interior styles. It features large glass viewing areas which present a captivating flame pattern, enhancing the visual appeal of the unit. The contemporary facade can be finished with a variety of trims and options, allowing homeowners to tailor the fireplace to their personal décor.

The DVT38 is also equipped with an easy-to-use electronic ignition system, further simplifying the operation. This feature ensures that lighting the fireplace is hassle-free, eliminating the need for matches or manual lighting. Additionally, many models come with a remote control option, allowing users to adjust settings from a distance, thereby enhancing convenience and usability.

Moreover, the DVT38 is built with durability in mind, incorporating high-quality materials that withstand the test of time while providing a reliable heating solution. Vermont Castings is renowned for its commitment to craftsmanship, and this model exemplifies that ethos.

In summary, the Vermont Casting DVT38 is an exquisite blend of functionality and design. With efficient heating capabilities, cutting-edge technology, and customizable aesthetics, it stands out as a premier choice for anyone looking to elevate their home heating experience. Whether for warmth or ambiance, the DVT38 is engineered to deliver satisfaction for years to come.