Vermont Casting DVT38 installation instructions Framing and Finishing, Nailing flanges

Page 6

Chateau™

Framing and Finishing

NOTE: The valve box assembly must be installed in the same room as the fireplace.

1.Choose the unit location.

2.The unit is shipped with four (4) nailing flanges mounted to the sides near the front corners. (Fig. 5)

3.Frame the fireplace with a header across the top of the standoff. (Fig. 6) It is very important to allow for the finished wall face along with marble, tiles or any

Bend

 

Line

 

3"

3"

(76mm) Min.

(76mm) Min.

 

1¹⁄₂"

 

(38mm)

 

Max. Hearth Height

FP1357

 

Fig. 5 Nailing flanges.

3" (76mm)

3"

FP1358

(76mm)

Fig. 6 Fireplace framing.

other noncombustible face finish material desired when setting the depth of the framing.

4.Attach the fireplace nailing flanges to the frame as shown in Figure 5.

5.The gas components are located in the control panel assembly attached to the right side of the unit. Choose the desired location on the wall or mantel for the valve box assembly. The conduit length is 5ʼ (1524mm). (Fig. 7) The framing dimensions for the box are 12¹⁄”L x 9¹⁄”W x 5⁵⁄”D (311mm x 235mm x 143mm). When the framing for the box is complete, remove the screws securing the valve box to the outer casing. Carefully remove the valve box and, without stressing the conduit, slide the box into the framed opening. Replace the screws removed from the side of the outer casing.

45" (1143mm)

Fig. 7 Valve box assembly location.

6.To secure the valve box assembly to the framing members, open the box door, remove extension knob(s). For units with two piece cover plates, re- move the front cover plate by removing the screws holding the front plate to the second plate. Discon- nect the wires for the pilot indicator and remove the second plate located at the top of the box.

For units with a one piece cover plate, remove the valve cover by removing the two (2) screws securing the valve cover to the box, hold the cover plate with one hand and disconnect the wires to the switch and pilot indicator (R models only). NOTE: Do not allow the valve cover plate to hang from the pilot indicator wires as this could damage the wires.

Secure the box to the framing through the two (2) holes at the top and one (1) on each side using sheet rock screws. (Fig. 8) After framing the box, replace the wires, the valve cover, the extension knob(s) in reverse order.

NOTE: The pilot indicator body is labelled +/-, make sure the positive wire on the pilot indicator goes to ground and the negative goes to the plug between the valve and the thermocouple.

6

20006081

Image 6
Contents INSTALLER/CONSUMER Safety Information What to do if YOU Smell GASTable of Contents Installation & Operating Instructions Locating Your FireplacePlease Review the Following Carefully Fireplace Dimensions DVT38 Clearance to Combustibles MantelsFraming and Finishing Nailing flangesGas Inlet and Manifold Pressures Gas Line InstallationFinal Finishing Gas SpecificationsRemote ON/OFF Switch Electrical Junction Box E Units OnlyElectronic Gas Control Valve General Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationQuick Reference for Fresh Air Restrictor Plate / Flue Baffle General Information Assembling Vent Pipes SK8 Venting Pipes Canadian InstallationsUSA Installations Horizontal TerminationSidewall Applications DVT44 onlyDVT38 only Sidewall Installation StepAlways install horizontal venting on a level plane Locate vent opening on wallFresh Air Restrictor Plate Vertical Through-the-Roof Installation Typical offset applicationMin 610mm Chimney Components Component Description Model NumberRestrictor Plates Installation Glass Information Glass CleaningGlass Frame Assembly Removal Operating InstructionsCeramic Refractory Installation Fresh Air Restrictor Plate AdjustmentLog, Lava Rock and Ember Placement Place log rear onto rear log bracket Flame & Temperature Adjustment Flame CharacteristicsRN/RP & EN/EP Models Lighting And Operating Instructions To Turn Off Gas To HeaterTurning Off the Gas to the Appliance Lighting and Operating InstructionsLighting Instructions Valve in the on positionTroubleshooting the Gas Control System SIT Nova 820 Millivolt ValveSIT 822 Valve with a Honeywell Electronic Ignitor Conversion Precautions Conversion ProcedureFuel Conversion Instructions Pilot Flame Adjustment Remove valve regulatorInjector Orifice Size Matrix Cleaning Electronic Ignition System MaintenanceCleaning the Standing Pilot Control System Battery Replacement for Ignitor ModuleDVT38, DVT44 DVT38, DVT44 DVT38 DVT44Fuel Conversion Kits Full Surround Mantel AccessoriesRemote Controls Model Functions ControlledChateau Chateau Product Covered by this Warranty If Warranty Service is NEEDED…Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %

DVT38 specifications

The Vermont Casting DVT38 is a standout model in the realm of contemporary gas fireplaces, epitomizing both innovative engineering and aesthetic elegance. Designed with a focus on efficiency and style, the DVT38 offers homeowners an exceptional heating experience while enhancing the ambiance of their living spaces.

One of the main features of the Vermont Casting DVT38 is its impressive heat output. With a BTU range that ensures warmth for larger areas, the fireplace is capable of efficiently heating spaces without consuming excessive fuel. This is a critical aspect for homeowners seeking both comfort and energy savings. The fireplace integrates a dual burner system, promoting a uniform heat distribution and ensuring that every corner of the room enjoys consistent warmth.

Another notable characteristic of the DVT38 is its advanced burner technology. The unique burner design allows for a natural gas or propane option, giving consumers flexibility based on availability and preference. The adjustable flame settings enable users to customize the heat output and ambiance, perfect for both cozy winter evenings and social gatherings.

In terms of aesthetics, the Vermont Casting DVT38 boasts a sophisticated design that complements various interior styles. It features large glass viewing areas which present a captivating flame pattern, enhancing the visual appeal of the unit. The contemporary facade can be finished with a variety of trims and options, allowing homeowners to tailor the fireplace to their personal décor.

The DVT38 is also equipped with an easy-to-use electronic ignition system, further simplifying the operation. This feature ensures that lighting the fireplace is hassle-free, eliminating the need for matches or manual lighting. Additionally, many models come with a remote control option, allowing users to adjust settings from a distance, thereby enhancing convenience and usability.

Moreover, the DVT38 is built with durability in mind, incorporating high-quality materials that withstand the test of time while providing a reliable heating solution. Vermont Castings is renowned for its commitment to craftsmanship, and this model exemplifies that ethos.

In summary, the Vermont Casting DVT38 is an exquisite blend of functionality and design. With efficient heating capabilities, cutting-edge technology, and customizable aesthetics, it stands out as a premier choice for anyone looking to elevate their home heating experience. Whether for warmth or ambiance, the DVT38 is engineered to deliver satisfaction for years to come.