Vermont Casting DVT38 Installation & Operating Instructions, Locating Your Fireplace

Page 3

Chateau™

Installation & Operating Instructions

This gas fireplace should be installed by a qualified installer in accordance with local building codes and with current CSA- B149.1 Installation codes for Gas Burning Appliances and Equipment. For USA Installations follow local codes and/or the current National Fuel Gas Code. ANSI Z223.1/NFPA 54.

FOR SAFE INSTALLATION AND OPERATION PLEASE NOTE THE FOLLOWING:

1 . This fireplace gives off high temperatures and should be located out of high traffic areas and away from furniture and draperies.

2.

Children and adults should be alerted to the hazards of the

 

high surface temperatures of this fireplace and should stay

 

away to avoid burns or ignition of clothing.

3.

CAUTION: Due to high glass surface temperature chil-

 

dren should be carefully supervised when in the same

 

room as fireplace.

4.

Under no circumstances should this fireplace be modified.

 

Parts removed for servicing should be replaced prior to

 

operating this fireplace again.

5.

Installation and any repairs to this fireplace must be per-

 

formed by a qualified installer, service agency or gas sup-

 

plier. A professional service person should be contacted to

 

inspect the fireplace annually. More frequent cleaning may

 

be required due to excess lint and dust from carpeting, bed-

 

ding material, etc.

6.

Control compartments, burners and air passages in this fire-

 

place should be kept clean and free of dust and lint. Make

 

sure that the gas valve and pilot light are turned off before

 

you attempt to clean this fireplace.

7.

The venting system (chimney) of this fireplace should be

 

checked at least once a year and if needed your venting

 

system should be cleaned.

8.

Keep the area around your fireplace clear of combustible

 

materials, gasoline and other flammable vapor and liquids.

 

This fireplace should not be used as a drying rack for cloth-

 

ing, nor should Christmas stockings or decorations be hung

This appliance may be installed in an aftermarket permanently located, manufactured home or mobile home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

The DVT38/44 has been approved for mobile home installations.

IMPORTANT:

PLEASE REVIEW THE FOLLOWING CAREFULLY

Remove any plastic from parts before turning the fire- place ON.

It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine.

It is not unusual for your Vermont Castings, Majestic Products gas fireplace to give off some odor the first time it is burned. This is due to the curing of the paint and any undetected oil from the manufacturing pro- cess.

Please ensure that your room is well ventilated- open all windows.

It is recommended that you burn your fireplace for at least ten (10) hours the first time you use it.

Locating Your Fireplace

on or around the fireplace.

9. Under no circumstances should any solid fuels (wood, coal,

paper or cardboard etc.) be used in this fireplace.

E A

Y

B

10. The flow of combustion and ventilation air must not be ob-

structed in any way.

11. When the fireplace is installed directly on carpeting, vinyl tile

or any combustible material other than wood, this fireplace

must be installed on a metal or wood panel extending the

full width and depth of the fireplace.

12. This fireplace requires adequate ventilation and combustion

air to operate properly.

Y

C

D

F

X

B

LU584-1

13. This fireplace must not be connected to a chimney flue

serving a separate solid fuel burning fireplace.

14. When the fireplace is not in use it is recommended that the

gas control valve be left in the “OFF” position.

NOTE: This appliance uses a fast acting thermocouple and must be replaced with same.

Proposition 65 Warning: Fuels used in gas, woodburning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. California Health & Safety Code Sec. 25249.6

20006081

Fig. 1 Locate gas fireplace.

A) Flat on wall

B) Cross corner

C) **Island

D) *Room divider

E) *Flat on wall corner

F) Chase installation

Y)6” minimum

Note (Fig. 1):

** Island (C) and Room Divider (D) installation is possible as long as the horizontal portion of the vent system (X) does not exceed 20ʼ (6 m). See details in Venting Section.

* When you install your Vermont Castings, Majestic Products fireplace in (D) Room divider or (E) Flat on wall corner positions (Y), a minimum of 6” (152 mm) clearance must be maintained from the perpendicular wall and the front side edge of the fire-

place.

3

 

Image 3
Contents What to do if YOU Smell GAS INSTALLER/CONSUMER Safety InformationTable of Contents Installation & Operating Instructions Locating Your FireplacePlease Review the Following Carefully Fireplace Dimensions DVT38 Mantels Clearance to CombustiblesNailing flanges Framing and FinishingGas Specifications Gas Line InstallationFinal Finishing Gas Inlet and Manifold PressuresRemote ON/OFF Switch Electrical Junction Box E Units OnlyElectronic Gas Control Valve Location of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2Quick Reference for Fresh Air Restrictor Plate / Flue Baffle Horizontal Termination Canadian InstallationsUSA Installations General Information Assembling Vent Pipes SK8 Venting PipesSidewall Applications DVT44 onlyDVT38 only Step Sidewall InstallationLocate vent opening on wall Always install horizontal venting on a level planeFresh Air Restrictor Plate Typical offset application Vertical Through-the-Roof InstallationMin 610mm Component Description Model Number Chimney ComponentsOperating Instructions Glass Information Glass CleaningGlass Frame Assembly Removal Restrictor Plates InstallationFresh Air Restrictor Plate Adjustment Ceramic Refractory InstallationLog, Lava Rock and Ember Placement Place log rear onto rear log bracket Flame & Temperature Adjustment Flame CharacteristicsRN/RP & EN/EP Models To Turn Off Gas To Heater Lighting And Operating InstructionsValve in the on position Lighting and Operating InstructionsLighting Instructions Turning Off the Gas to the ApplianceSIT Nova 820 Millivolt Valve Troubleshooting the Gas Control SystemSIT 822 Valve with a Honeywell Electronic Ignitor Conversion Precautions Conversion ProcedureFuel Conversion Instructions Remove valve regulator Pilot Flame AdjustmentInjector Orifice Size Matrix Battery Replacement for Ignitor Module MaintenanceCleaning the Standing Pilot Control System Cleaning Electronic Ignition SystemDVT38, DVT44 DVT38 DVT44 DVT38, DVT44Fuel Conversion Kits Model Functions Controlled AccessoriesRemote Controls Full Surround MantelChateau Chateau If Warranty Service is NEEDED… Product Covered by this WarrantyModel EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings

DVT38 specifications

The Vermont Casting DVT38 is a standout model in the realm of contemporary gas fireplaces, epitomizing both innovative engineering and aesthetic elegance. Designed with a focus on efficiency and style, the DVT38 offers homeowners an exceptional heating experience while enhancing the ambiance of their living spaces.

One of the main features of the Vermont Casting DVT38 is its impressive heat output. With a BTU range that ensures warmth for larger areas, the fireplace is capable of efficiently heating spaces without consuming excessive fuel. This is a critical aspect for homeowners seeking both comfort and energy savings. The fireplace integrates a dual burner system, promoting a uniform heat distribution and ensuring that every corner of the room enjoys consistent warmth.

Another notable characteristic of the DVT38 is its advanced burner technology. The unique burner design allows for a natural gas or propane option, giving consumers flexibility based on availability and preference. The adjustable flame settings enable users to customize the heat output and ambiance, perfect for both cozy winter evenings and social gatherings.

In terms of aesthetics, the Vermont Casting DVT38 boasts a sophisticated design that complements various interior styles. It features large glass viewing areas which present a captivating flame pattern, enhancing the visual appeal of the unit. The contemporary facade can be finished with a variety of trims and options, allowing homeowners to tailor the fireplace to their personal décor.

The DVT38 is also equipped with an easy-to-use electronic ignition system, further simplifying the operation. This feature ensures that lighting the fireplace is hassle-free, eliminating the need for matches or manual lighting. Additionally, many models come with a remote control option, allowing users to adjust settings from a distance, thereby enhancing convenience and usability.

Moreover, the DVT38 is built with durability in mind, incorporating high-quality materials that withstand the test of time while providing a reliable heating solution. Vermont Castings is renowned for its commitment to craftsmanship, and this model exemplifies that ethos.

In summary, the Vermont Casting DVT38 is an exquisite blend of functionality and design. With efficient heating capabilities, cutting-edge technology, and customizable aesthetics, it stands out as a premier choice for anyone looking to elevate their home heating experience. Whether for warmth or ambiance, the DVT38 is engineered to deliver satisfaction for years to come.