Vermont Casting DVT38 installation instructions Clearance to Combustibles, Mantels

Page 5

Chateau™

 

Clearance to Combustibles

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Appliance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top Standoffs

0” (0mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bottom

0” (0mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Side Standoffs

0” (0mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

...........................................Back Standoffs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Venting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Horizontal Termination through-a-side wall:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J

 

 

 

I

H

 

 

 

 

 

 

 

 

Vertical Sections:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mantel

 

 

 

 

 

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sides

2¹⁄” (64mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Leg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Horizontal Sections:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

..................................................Top

3¹⁄” (89mm)

 

 

 

CFM164b

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bottom

1¹⁄” (38mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LK

 

 

 

 

 

 

 

 

 

Sides

2¹⁄” (64mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

 

 

 

 

 

 

 

 

 

Vertical Vent Application:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Side of Fireplace

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sides

1¹⁄” (38mm)

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mantels

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The height that a combustible mantel is fitted above the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fireplace is dependent on the depth of the mantel. This

 

 

 

 

 

 

 

 

 

 

 

 

 

 

also applies to the distance between the mantel leg (if

 

 

 

 

 

 

Noncombustible

 

 

 

 

 

fitted) and the fireplace.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Finish Material

 

 

 

 

 

For the correct mounting height and widths refer to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figs. 4a and 4b, the following Mantel Charts.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Noncombustible mantels and legs may be installed at

 

 

 

 

 

 

 

 

 

 

 

 

 

 

any height and width around the appliance.

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM170a

When using paint or lacquer to finish the mantel, such

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

paint or lacquer must be heat resistant to prevent

 

 

 

 

 

 

Mantel

 

 

Mantel Leg from Side

discoloration.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ref.

 

Leg Depth

Ref.

 

of Comb. Opening

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

12” (305mm)

K

 

 

12” (305mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combustible

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

 

9” (229mm)

L

 

 

 

9” (229mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Framing and Fin-

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

 

 

 

 

 

 

ish Wall Above

 

 

H

 

6” (152mm)

M

 

 

 

6” (152mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standoffs

 

 

 

I

 

4” (102mm)

N

 

 

 

4” (102mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

May use combus-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J

 

3” (76mm)

O

 

 

 

3” (76mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tible facing mate-

 

 

 

 

 

 

 

 

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

rial in this area

 

Fig. 4b

Combustible mantel leg minimum installation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

 

 

 

 

 

 

 

 

 

Standoff

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hearth

 

 

 

 

 

 

 

 

 

 

 

 

Z

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

B

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A hearth is not mandatory but is recommended for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

aesthetic purposes. We recommend a noncombustible

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

hearth which projects out 12” (305mm) or more from

 

Noncombustible Finish

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the front of the fireplace. The hearth cannot exceed 1¹⁄

 

Material

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(38mm) in height from bottom of fireplace for ease of

 

(Such as Dura Rock)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM146c

 

Fireplace Front

 

 

 

 

 

 

 

 

 

 

Top of Sheet

 

 

door accessibility. (Fig. 5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Metal

 

 

Cold climate installation recommendation:

 

 

 

 

 

 

Mantel

Chart

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When installing this unit against a non-

 

 

 

Mantel Shelf

 

 

 

 

 

 

Mantel from Top

 

 

 

 

 

insulated exterior wall or chase, it is

Ref.

or Breast Plate

Ref.

 

 

 

 

of Comb. Chamber

 

 

 

 

 

 

 

 

 

 

 

 

mandatory the outer walls be insulated to

 

 

 

 

Depth

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

conform to applicable insulation codes.

 

V

 

10” (254 mm)

A

 

 

 

 

 

 

 

10” (254 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

 

9” (229 mm)

B

 

 

 

 

 

 

 

9” (229 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X

 

8” (203 mm)

C

 

 

 

8” (203 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

 

7” (178 mm)

D

 

 

 

7” (178 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Z

 

6” (152 mm)

E

 

 

 

6” (152 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 4a Combustible mantel minimum installation.

20006081

5

Image 5
Contents What to do if YOU Smell GAS INSTALLER/CONSUMER Safety InformationTable of Contents Please Review the Following Carefully Installation & Operating InstructionsLocating Your Fireplace Fireplace Dimensions DVT38 Mantels Clearance to CombustiblesNailing flanges Framing and FinishingFinal Finishing Gas Line InstallationGas Inlet and Manifold Pressures Gas SpecificationsElectronic Gas Control Valve Remote ON/OFF SwitchElectrical Junction Box E Units Only Location of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2Quick Reference for Fresh Air Restrictor Plate / Flue Baffle USA Installations Canadian InstallationsGeneral Information Assembling Vent Pipes SK8 Venting Pipes Horizontal TerminationDVT38 only Sidewall ApplicationsDVT44 only Step Sidewall InstallationLocate vent opening on wall Always install horizontal venting on a level planeFresh Air Restrictor Plate Typical offset application Vertical Through-the-Roof InstallationMin 610mm Component Description Model Number Chimney ComponentsGlass Frame Assembly Removal Glass Information Glass CleaningRestrictor Plates Installation Operating InstructionsFresh Air Restrictor Plate Adjustment Ceramic Refractory InstallationLog, Lava Rock and Ember Placement Place log rear onto rear log bracket RN/RP & EN/EP Models Flame & Temperature AdjustmentFlame Characteristics To Turn Off Gas To Heater Lighting And Operating InstructionsLighting Instructions Lighting and Operating InstructionsTurning Off the Gas to the Appliance Valve in the on positionSIT Nova 820 Millivolt Valve Troubleshooting the Gas Control SystemSIT 822 Valve with a Honeywell Electronic Ignitor Fuel Conversion Instructions Conversion PrecautionsConversion Procedure Remove valve regulator Pilot Flame AdjustmentInjector Orifice Size Matrix Cleaning the Standing Pilot Control System MaintenanceCleaning Electronic Ignition System Battery Replacement for Ignitor ModuleDVT38, DVT44 DVT38 DVT44 DVT38, DVT44Fuel Conversion Kits Remote Controls AccessoriesFull Surround Mantel Model Functions ControlledChateau Chateau If Warranty Service is NEEDED… Product Covered by this WarrantyModel EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings

DVT38 specifications

The Vermont Casting DVT38 is a standout model in the realm of contemporary gas fireplaces, epitomizing both innovative engineering and aesthetic elegance. Designed with a focus on efficiency and style, the DVT38 offers homeowners an exceptional heating experience while enhancing the ambiance of their living spaces.

One of the main features of the Vermont Casting DVT38 is its impressive heat output. With a BTU range that ensures warmth for larger areas, the fireplace is capable of efficiently heating spaces without consuming excessive fuel. This is a critical aspect for homeowners seeking both comfort and energy savings. The fireplace integrates a dual burner system, promoting a uniform heat distribution and ensuring that every corner of the room enjoys consistent warmth.

Another notable characteristic of the DVT38 is its advanced burner technology. The unique burner design allows for a natural gas or propane option, giving consumers flexibility based on availability and preference. The adjustable flame settings enable users to customize the heat output and ambiance, perfect for both cozy winter evenings and social gatherings.

In terms of aesthetics, the Vermont Casting DVT38 boasts a sophisticated design that complements various interior styles. It features large glass viewing areas which present a captivating flame pattern, enhancing the visual appeal of the unit. The contemporary facade can be finished with a variety of trims and options, allowing homeowners to tailor the fireplace to their personal décor.

The DVT38 is also equipped with an easy-to-use electronic ignition system, further simplifying the operation. This feature ensures that lighting the fireplace is hassle-free, eliminating the need for matches or manual lighting. Additionally, many models come with a remote control option, allowing users to adjust settings from a distance, thereby enhancing convenience and usability.

Moreover, the DVT38 is built with durability in mind, incorporating high-quality materials that withstand the test of time while providing a reliable heating solution. Vermont Castings is renowned for its commitment to craftsmanship, and this model exemplifies that ethos.

In summary, the Vermont Casting DVT38 is an exquisite blend of functionality and design. With efficient heating capabilities, cutting-edge technology, and customizable aesthetics, it stands out as a premier choice for anyone looking to elevate their home heating experience. Whether for warmth or ambiance, the DVT38 is engineered to deliver satisfaction for years to come.