Empire Comfort Systems PV-28SV55-(C,G)2H(N,P)-1 Colinear Direct Vent Pitched Roof Installation

Page 26

VERTICAL EXAMPLES FOR COLINEAR DIRECT VENT

Note: Exhaust must be a minimum of 3” above air intake inlet.

EXHAUST

TERMINATION CAP

MODEL PVVTC, PTRAP

OR 2 90° ELBOWS

HEIGHT

FLASHING

REQUIRED

SINGLE FLUE

MODEL PVVK-SH

AIR INTAKE

PTRAP, 2 90° ELBOWS (SUPPLIED

3” - 24”BY INSTALLER) OR TERMINATION CAP MODEL PVVTC. PTRAP TO FACE

AWAY FROM ROOF.

HEIGHT

OPTION

12

X

CO-LINEAR

DIRECT VENT ADAPTER

MODEL PVCA

Colinear Direct Vent - Insert Installation

Figure 29

Determining Minimum Vent Height Above the Roof

ROOF PITCH

H (Min.)

Flat to 6/12

12” (305 mm)

 

 

6/12 to 7/12

15” (381 mm)

Over 7/12 to 8/12

18” (457 mm)

Over 8/12 to 16/12

24” (610 mm)

Over 16/12 to 21/12

36” (914 mm)

Colinear Direct Vent - Pitched Roof Installation

Figure 30

WARNING: Major U.S. building codes specify minimum chimney and/or vent height above the rooftop. These minimum heights are necessary in the interest of safety. These specifications are summarized in Figure 30.

Figure 31

In both vertical and horizontal colinear direct vent applications, a colinear transition plate model PVCT can be used to minimize clearances between intake and exhaust pipes.

For exhaust and intake air, cap pipes with any of the following: Vertical termination cap (model #PVVTC), PTrap, or two 90º elbows. When transi- tion plate (model PVCT) is used, two termination caps (model PVVTC) may NOT be used.

Note: If transition plate (model PVCT) is used, the measurement for center to center of the pipes will be 2.5”. If the transition plate (model PVCT) is not used, the measurement for center to center of the pipes can be 3” to 24” maximum.

Page 26

24820-1-0409

Image 26
Contents Empire Table of Contents Important Safety Information This is a Heating ApplianceSafety Information for Users of LP-GAS LP-GAS Warning OdorRequirements for Massachusetts Vent Directly BELOW. Keep Clear of ALL ObstructionsGAS Supply Installing a New Main Gas CockPressure Testing of the Gas Supply System Recommended Gas Pipe DiameterIntroduction Specifications Installation Instructions General Safety InformationClearances for Direct Vent Heater Installation for Direct VentInstallation on Rugs and Tile Locating Wall OpeningHeater Installation for Single Flue Clearances for Single FlueHeater with Pedestal and Single Flue Adaptor Specifications Heater without pedestalFireplace Insert with Mantel Surround with Slim Top Panel Fireplace Insert with Mantel Surround with Short Top Panel Clearance to Combustibles Freestanding UnitsRough Framing Dimensions Insert Into Masonry FireplaceWall Clearances LOG SET Installation Instructions Log Installation All LogsVent Examples for Single Flue Single Flue Vertical Vent Run Shroud Kit Model# Pvsh Venting for Existing Fireplace InstallationSingle Flue Venting with Shroud Installed Single Flue Vertical Vent Run With 45 degree elbows Determining Minimum Vent Height AboveRoof Determining Minimum Vent Height Above the Roof PVVK-CFA Flex Vent KITAvailable from Empire Comfort Systems, Inc PVVK-SH Horizontal Vent Adaptor KIT Horizontal Examples for Colinear Direct Vent Vertical Examples for Colinear Direct Vent Colinear Direct Vent Pitched Roof Installation Pvca Horizontal Colinear Direct Vent Adaptor Colinear adaptorPvvtc Termination CAP Vent KIT Termination CapHorizontal Application Pvct Colinear Transition Vent KITFlat Roof or Chimney Application Direct Vent System Building Exterior View Direct Vent Installation InstructionsHorizontal Venting Minimum Exterior Grade Dimension Unit Without Pedestal Minimum Exterior Grade Dimension Unit With PedestalPVVK-24H and PVVK-48H Vent KIT StepPVVK-24H and PVVK-48H Vent KIT GAS Connection Installation Instructions GAS Connection Line SupplyOperating Instructions Checklist Lighting Instructions For Your Safety Read Before Lighting FAN Operation GAS Conversion Instructions Conversion Instructions from LP Propane GAS to Natural GASConversion Instructions from Natural GAS to LP Propane GAS Automatic Humidifier Operation Installation Instruction for TMV2 Two Stage Thermostat Model Optional ControllersEconomy Display Mode Wiring Wiring DiagramGeneral Information MaintenanceOver Temperature Cut Out Paint Curing First FiringMain Burner Drawing Cleaning Main Burner Front door removal drawing Glass CleaningGlass Assembly Replacement General Glass InformationLOG Placement Unit Operating FaultsResetting the Heater Heat Exchanger Surround Installation InstructionsMain Convection FAN Pedestal Installation Instructions Optional Pedestal Assembly InstallationParts List Index Part Number DescriptionGAS Line Rear Parts View Parts View Warranty Terms Purchase Date Dealer Name/PhoneWarranty Parts HOW to Order Repair PartsParts Not Under Warranty Master Parts Distributor ListComfort Systems