Empire Comfort Systems PV-28SV55-(C,G)2H(N,P)-1 LOG SET Installation Instructions

Page 18

LOG SET INSTALLATION INSTRUCTIONS

Log Installation

All Logs

The gas log set (front left log, front right log, center log and rear

The positioning of the logs is critical to the safe and clean opera-

log) is pre-set and installed in the factory. Only the top left log and

tion of this heater. Sooting and other problems may result if the

top right log are packaged separately inside the firebox for instal-

logs are not properly and firmly positioned in the appliance.

lation by the installer.

6. Prior to positioning of top left log and top right log, inspect

1. To access the log set parcel, lift off top panel.

 

front burner and rear burner for particles or dust accumula-

2. Pivot left and right panels open.

 

tion on top of burners. If any particles or dust is visible on top

 

of front or rear burners, remove particles before placing top

3. Unlatch main door latches located on right and left hand side

 

 

left log and top right log into position.

of the heater, remove door.

 

7.

Position top left log into locating pin on rear log and rest on

4. Carefully remove top left log and top right log from firebox

 

center log. See Figure 15.

and remove cardboard protection from center log and middle

 

8.

Position top right log into locating slot on rear log. See Fig-

log and all packaging materials.

 

ure 15.

Note: Positions of front left log, front right log, center log,

 

9.

After top left log and top right log have been placed in posi-

and rear log have been preset at the factory and their loca-

 

tion and safety check has been carried out, install door and

tions should not be changed. Check that logs have not been

 

 

latch securely with latches located on right and left side of

damaged in transit.

 

 

heater.

5. Carefully remove wrapping from top left log and top right

 

 

 

log.

 

 

Note: Before you begin: Do not handle these logs with your bare

 

 

hands! Always wear gloves to prevent skin irritation. After

 

 

handling logs, wash your hands gently with soap and wa-

 

 

ter.

TOP LEFT LOG

REAR LOG

TOP RIGHT LOG

CENTER LOG

 

FRONT RIGHT LOG

 

 

 

FRONT LEFT LOG Figure 15

 

 

 

LOG SET DIAGRAM - A

1 - REAR LOG

 

 

4 - TOP LEFT LOG

3 - TOP RIGHT LOG

The Gas Log Kit contains the following:

 

 

 

 

1)Rear Log

2) Center Log

3)Top Right Log

4)Top Left Log

5)Front Left Log

6) Front Right Log

5 - FRONT LEFT LOG

6 - FRONT RIGHT LOG

Figure 16

2 - CENTER LOG

 

Page 18

24820-1-0409

Image 18
Contents Empire Table of Contents Important Safety Information This is a Heating ApplianceSafety Information for Users of LP-GAS LP-GAS Warning OdorRequirements for Massachusetts Vent Directly BELOW. Keep Clear of ALL ObstructionsGAS Supply Installing a New Main Gas CockPressure Testing of the Gas Supply System Recommended Gas Pipe DiameterIntroduction Specifications Installation Instructions General Safety InformationClearances for Direct Vent Heater Installation for Direct VentInstallation on Rugs and Tile Locating Wall OpeningHeater Installation for Single Flue Clearances for Single FlueHeater with Pedestal and Single Flue Adaptor Specifications Heater without pedestalFireplace Insert with Mantel Surround with Slim Top Panel Fireplace Insert with Mantel Surround with Short Top Panel Clearance to Combustibles Freestanding UnitsRough Framing Dimensions Insert Into Masonry FireplaceWall Clearances LOG SET Installation Instructions Log Installation All LogsVent Examples for Single Flue Venting for Existing Fireplace Installation Single Flue Venting with Shroud InstalledSingle Flue Vertical Vent Run Shroud Kit Model# Pvsh Determining Minimum Vent Height Above RoofSingle Flue Vertical Vent Run With 45 degree elbows PVVK-CFA Flex Vent KIT Available from Empire Comfort Systems, IncDetermining Minimum Vent Height Above the Roof PVVK-SH Horizontal Vent Adaptor KIT Horizontal Examples for Colinear Direct Vent Vertical Examples for Colinear Direct Vent Colinear Direct Vent Pitched Roof Installation Pvca Horizontal Colinear Direct Vent Adaptor Colinear adaptorPvvtc Termination CAP Vent KIT Termination CapPvct Colinear Transition Vent KIT Flat Roof or Chimney ApplicationHorizontal Application Direct Vent Installation Instructions Horizontal VentingDirect Vent System Building Exterior View Minimum Exterior Grade Dimension Unit Without Pedestal Minimum Exterior Grade Dimension Unit With PedestalPVVK-24H and PVVK-48H Vent KIT StepPVVK-24H and PVVK-48H Vent KIT GAS Connection Installation Instructions GAS Connection Line SupplyOperating Instructions Checklist Lighting Instructions For Your Safety Read Before Lighting FAN Operation GAS Conversion Instructions Conversion Instructions from LP Propane GAS to Natural GASConversion Instructions from Natural GAS to LP Propane GAS Automatic Humidifier Operation Installation Instruction for TMV2 Two Stage Thermostat Model Optional ControllersEconomy Display Mode Wiring Wiring DiagramGeneral Information MaintenanceOver Temperature Cut Out Paint Curing First FiringMain Burner Drawing Cleaning Main Burner Front door removal drawing Glass CleaningGlass Assembly Replacement General Glass InformationUnit Operating Faults Resetting the HeaterLOG Placement Surround Installation Instructions Main Convection FANHeat Exchanger Pedestal Installation Instructions Optional Pedestal Assembly InstallationParts List Index Part Number DescriptionGAS Line Rear Parts View Parts View Warranty Terms Purchase Date Dealer Name/PhoneWarranty Parts HOW to Order Repair PartsParts Not Under Warranty Master Parts Distributor ListComfort Systems