VENT SYSTEM IDENTIFICATION

Installing Vent Components (Figure 36)

Begin the vent system installation by installing the first Simpson Duravent component, 90° elbow to the starting collars or straight pipe on the top of the appliance, then the straight pipe length and then horizontal or vertical termination kit.

NOTE:Allouterconnectionjointsmustbesealedwithaluminum tape, screws or silicone sealant rated above 300°F/149°C. The inner flue joints do not require any sealant.

Simpson Duravent vent system components lock into place by

sliding the concentric pipe section with four (4) equally spaced interior beads onto the appliance collar or previously installed component end with four (4) equally spaced indented sections. When the internal beads of each starting outer pipe line up, rotate pipe section clockwise 90° (approximately 3 inches). The vent pipe is now locked together.

Continue adding components per the pre-planned vent system configuration. Be certain that each succeeding vent component is securely fitted and locked into the preceding component in the vent system.

WALL THIMBLE

(MAXIMUM OF THREE 90 ELBOWS)

(MAXIMUM OF TWO 90 ELBOWS)

Special DV Vent Kits - Simpson Duravent and Empire Comfort Systems, Inc.

Can be purchased from Empire Comfort Systems, Inc.

DVVK-5R

Direct-Vent Fireplace Vent Kit for Rear Vent, 6 to 12 inch wall

 

thickness, Includes SD-1208, SD-1247, and SD-2184

DVVK-5T

Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 4

 

to 6 inch wall thickness, Includes SD-1290, SD-1284, SD-1208

 

and SD-1247

DVVK-5V

Direct Vent Fireplace Vent Kit - Vertical, Includes SD-1291,

 

SD-1253, and SD-1243

 

Figure 36

Special Venting Components

Simpson Dura-Vent

Can be purchased from Simpson Duravent or from

Empire Comfort Systems, Inc.

Part Number

Description

SD-1208

6" Pipe Length

SD-1207

9" Pipe Length

SD-1206

12" Pipe Length

SD-1204

24" Pipe Length

SD-1203

36" Pipe Length

SD-1202

48" Pipe Length

SD-1211

Adjustable Pipe Length 11 - 14 5/8"

SD-1284

Horizontal Square Termination Cap

SD-1250

Vinyl Siding Standoff

SD-1245

45° Elbow

SD-1290

90° Elbow

SD-1249

Wall Firestop

SD-1263

Ceiling Firestop

SD-1243

Roof Flashing - 0/12 to 6/12 Roof Pitch

SD-1253

Storm Collar

SD-91291

High Wind Vertical Top

SD-1281

36" Snorkel

SD-1282

14" Firestop Snorkel

SD-1247

Wall Thimble Firestop

17375-10-0706

Page 23

Image 23
Contents Effective Date Millivolt Standing PilotIntermittent Pilot Remote RF ModelsMain Title Important Safety Information Some Points to Remember LP-GAS Warning OdorNo Odor Detected Odor Fade Vent Directly BELOW. Keep Clear of ALL Obstructions Requirements for MassachusettsIntroduction Fireplace Dimensions SpecificationsLocating Fireplace ClearancesChecking Manifold Pressures Installing a New Main Gas CockGAS Supply Converting flue take-off to rear venting Rear Vent ConversionVent Pipe Clearance InstallationFraming and Finishing Finishing Figures 12 Flush Mount Mantel Installation FigureFraming Figure VERTICAL, 90 Elbow with Horizontal Termination Flush Wall InstallationCombustible Surround Installation Vent Runs Figures 14, 15, 16, 17Model VERTICAL, 90 Elbow to Horizontal OUT the WallExample B Venting Fireplace TOPTo Use the Vent Graph Figure Example aTypical Basement Installation Below Grade InstallationCutting the Hole Figures Positioning the FireplaceExamples TOP Vent RUN Venting Fireplace Rear Dimensions in FeetExamples Rear Vent RUN Information on Various Venting Routes and Components Vertical Sidewall InstallationsTermination Clearances Vent Clearances Vent System Identification Installing Vent Components FigureFraming and Finishing Installing Support Brackets FigureSee Horizontal Termination Page 25 and Vertical Termination Horizontal TerminationDVVK-5F Flex Vent Instructions InstallationDetermining Minimum Vent Height Above the Roof General MaintenanceInstalling the Vent System in a Chase Vertical TerminationVertical Termination Reassembly and Resealing Vent Pipe SystemLOG Placement 3 LOG SET Pilot Flame Figure Operating InstructionsMillivolt System Initial LightingTRW Standing Pilot Wiring Diagram Standing Pilot Lighting Instructions For Your SAFETY, Read Before LightingGlass soots Standing Pilot TroubleshootingFrequent pilot outage problem Pilot and main burner extinguish while in operationElectrical Connection Figure Intermittent Pilot Wiring DiagramIntermittent Pilot Operating Instructions Damage, personal injury or loss of life Intermittent Pilot Lighting InsturctionsOperation Intermittent Pilot TroubleshootingS8600H Intermittent Ignition Module Specifications CheckoutMain Burner Operation Safety LockoutIgnition System Checks Check ignition cable. Make sure ARC Length ActionIntermittent Pilot Troubleshooting RF Standing Pilot Operating Instructions Status Action RF Transmitter FunctionsRF Wiring Diagram Wiring Diagram with BlowerWhat to do if YOU Smell GAS RF Standing Pilot Lighting InstructionsMaintenance and Service Parts View Index Part Number Description DVP42 DVP48 Parts ListParts List Blower Wheels FBB4 Optional Variable Speed Blower InstallationBlower Motor Volt AC Optional Brick Liner Installation Instructions Junction BOX Wiring Installation InstructionsFBB4 AccessoriesService Notes HOW to Order Repair Parts Service Notes Service Notes 17375-10-0706

DVP42FP3(0,1,2,3)(N,P)-1, DVP42FP9(1,3)(N,P)-1, DVP48FP7(0,1,2,3)(N,P)-1, DVP48FP3(0,1,2,3)(N,P)-1, DVP48FP9(1,3)(N,P)-1 specifications

Empire Comfort Systems is a well-established name in the heating and comfort industry, and their line of direct vent gas fireplaces is a testament to their commitment to quality, efficiency, and innovative design. Among their offerings, models such as the DVP42FP9(1,3)(N,P)-1, DVP42FP7(0,1,2,3)(N,P)-1, DVP48FP9(1,3)(N,P)-1, DVP48FP7(0,1,2,3)(N,P)-1, and DVP42FP3(0,1,2,3)(N,P)-1 stand out for their remarkable features and technologies.

One of the key characteristics of these models is their direct vent technology, which allows them to draw in air from outside for combustion while venting exhaust safely outside. This feature enhances safety and efficiency, making them suitable for a variety of home environments. The models are equipped with adjustable flame control, allowing users to customize the ambiance according to their preferences, whether they seek a cozy, intimate setting or a more vibrant and warm atmosphere.

The DVP series is designed for easy installation and flexibility in placement, offering venting options that can accommodate different room layouts. The fireplaces feature easy-to-use electronic ignitions, alongside manual controls, ensuring reliability and ease of operation. Furthermore, the units are compatible with both natural gas and propane, providing versatility depending on the homeowner's fuel preferences.

Another crucial aspect of these models is their focus on energy efficiency. With advanced combustion systems, they maximize heat output while minimizing gas consumption, making them an environmentally friendly option. The fireplaces produce a significant amount of BTUs, providing adequate heating for various room sizes, while also featuring efficient heat distribution systems that ensure warmth reaches every corner.

Aesthetic appeal is not compromised with the DVP series. These fireplaces come with a variety of attractive front designs, media options such as logs or crystals, and customizable trim finishes. This versatility allows homeowners to select a unit that complements their interior décor seamlessly.

In summary, Empire Comfort Systems' DVP42FP9, DVP42FP7, DVP48FP9, DVP48FP7, and DVP42FP3 models boast advanced technologies, energy efficiency, and aesthetic versatility. Each unit embodies comfort and modernity, making them an excellent addition to any home looking to enhance its heating solution while maintaining an elegant and welcoming atmosphere. With a focus on safety, user-friendliness, and design, these direct vent gas fireplaces continue to set a standard in the heating industry.