Empire Comfort Systems DVP48FP3(0,1,2,3)(N,P)-1 Intermittent Pilot Lighting Insturctions

Page 36

INTERMITTENT PILOT LIGHTING INSTURCTIONS

FOR YOUR SAFETY, READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property

damage, personal injury or loss of life.

A. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

B.Before lighting smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

What To Do If You Smell Gas

Do not try to light any appliance.

Do not touch any electrical switch;

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire depart- ment.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.Stop! Read the safety information above. 2.Set the thermostat to lowest setting. 3.Turn off all electric power to the appliance.

4.This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

GAS CONTROL KNOB

SHOWN IN "OFF” POSITION.

OFF

ON

HONEYWELL

5.Lower louver front assembly.

6. Turn gas control knob clockwise to "OFF."

7.Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.

8.Turn gas control knob counterclockwise to "ON".

9.Close louver front assembly.

10.Turn on all electric power to the appliance.

11.Set thermostat to desired setting.

12.If the appliance will not operate, follow the instructions "TO TURN OFF GAS TO APPLIANCE" and call your service technician or gas supplier.

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to lowest setting. (if applicable.)

2.Turn off all electric power to the appliance if service is to be performed.

3.Open bottom louver assembly.

4.Turn gas control knob clockwiseto "OFF". Do not force.

5.Close bottom louver assembly.

Page 36

17375-10-0706

Image 36
Contents Millivolt Standing Pilot Intermittent PilotRemote RF Models Effective DateMain Title Important Safety Information LP-GAS Warning Odor No Odor Detected Odor FadeSome Points to Remember Requirements for Massachusetts Vent Directly BELOW. Keep Clear of ALL ObstructionsIntroduction Specifications Fireplace DimensionsClearances Locating FireplaceInstalling a New Main Gas Cock GAS SupplyChecking Manifold Pressures Rear Vent Conversion Converting flue take-off to rear ventingInstallation Framing and FinishingVent Pipe Clearance Flush Mount Mantel Installation Figure Framing FigureFinishing Figures 12 Flush Wall Installation Combustible Surround InstallationVent Runs Figures 14, 15, 16, 17 VERTICAL, 90 Elbow with Horizontal TerminationVERTICAL, 90 Elbow to Horizontal OUT the Wall ModelVenting Fireplace TOP To Use the Vent Graph FigureExample a Example BBelow Grade Installation Typical Basement InstallationPositioning the Fireplace Cutting the Hole FiguresExamples TOP Vent RUN Dimensions in Feet Venting Fireplace RearExamples Rear Vent RUN Vertical Sidewall Installations Termination ClearancesInformation on Various Venting Routes and Components Vent Clearances Installing Vent Components Figure Vent System IdentificationInstalling Support Brackets Figure Framing and FinishingHorizontal Termination See Horizontal Termination Page 25 and Vertical TerminationInstallation DVVK-5F Flex Vent InstructionsGeneral Maintenance Installing the Vent System in a ChaseVertical Termination Determining Minimum Vent Height Above the RoofReassembly and Resealing Vent Pipe System Vertical TerminationLOG Placement 3 LOG SET Operating Instructions Millivolt SystemInitial Lighting Pilot Flame FigureTRW Standing Pilot Wiring Diagram For Your SAFETY, Read Before Lighting Standing Pilot Lighting InstructionsStanding Pilot Troubleshooting Frequent pilot outage problemPilot and main burner extinguish while in operation Glass sootsIntermittent Pilot Wiring Diagram Intermittent Pilot Operating InstructionsElectrical Connection Figure Intermittent Pilot Lighting Insturctions Damage, personal injury or loss of lifeIntermittent Pilot Troubleshooting S8600H Intermittent Ignition Module SpecificationsCheckout OperationSafety Lockout Main Burner OperationARC Length Action Ignition System Checks Check ignition cable. Make sureIntermittent Pilot Troubleshooting RF Standing Pilot Operating Instructions RF Transmitter Functions Status ActionWiring Diagram with Blower RF Wiring DiagramRF Standing Pilot Lighting Instructions What to do if YOU Smell GASMaintenance and Service Parts View Parts List Index Part Number Description DVP42 DVP48Parts List FBB4 Optional Variable Speed Blower Installation Blower MotorBlower Wheels Volt AC Junction BOX Wiring Installation Instructions Optional Brick Liner Installation InstructionsAccessories FBB4Service Notes HOW to Order Repair Parts Service Notes Service Notes 17375-10-0706

DVP42FP3(0,1,2,3)(N,P)-1, DVP42FP9(1,3)(N,P)-1, DVP48FP7(0,1,2,3)(N,P)-1, DVP48FP3(0,1,2,3)(N,P)-1, DVP48FP9(1,3)(N,P)-1 specifications

Empire Comfort Systems is a well-established name in the heating and comfort industry, and their line of direct vent gas fireplaces is a testament to their commitment to quality, efficiency, and innovative design. Among their offerings, models such as the DVP42FP9(1,3)(N,P)-1, DVP42FP7(0,1,2,3)(N,P)-1, DVP48FP9(1,3)(N,P)-1, DVP48FP7(0,1,2,3)(N,P)-1, and DVP42FP3(0,1,2,3)(N,P)-1 stand out for their remarkable features and technologies.

One of the key characteristics of these models is their direct vent technology, which allows them to draw in air from outside for combustion while venting exhaust safely outside. This feature enhances safety and efficiency, making them suitable for a variety of home environments. The models are equipped with adjustable flame control, allowing users to customize the ambiance according to their preferences, whether they seek a cozy, intimate setting or a more vibrant and warm atmosphere.

The DVP series is designed for easy installation and flexibility in placement, offering venting options that can accommodate different room layouts. The fireplaces feature easy-to-use electronic ignitions, alongside manual controls, ensuring reliability and ease of operation. Furthermore, the units are compatible with both natural gas and propane, providing versatility depending on the homeowner's fuel preferences.

Another crucial aspect of these models is their focus on energy efficiency. With advanced combustion systems, they maximize heat output while minimizing gas consumption, making them an environmentally friendly option. The fireplaces produce a significant amount of BTUs, providing adequate heating for various room sizes, while also featuring efficient heat distribution systems that ensure warmth reaches every corner.

Aesthetic appeal is not compromised with the DVP series. These fireplaces come with a variety of attractive front designs, media options such as logs or crystals, and customizable trim finishes. This versatility allows homeowners to select a unit that complements their interior décor seamlessly.

In summary, Empire Comfort Systems' DVP42FP9, DVP42FP7, DVP48FP9, DVP48FP7, and DVP42FP3 models boast advanced technologies, energy efficiency, and aesthetic versatility. Each unit embodies comfort and modernity, making them an excellent addition to any home looking to enhance its heating solution while maintaining an elegant and welcoming atmosphere. With a focus on safety, user-friendliness, and design, these direct vent gas fireplaces continue to set a standard in the heating industry.