Empire Comfort Systems DVP48FP7(0,1,2,3)(N,P)-1 Specifications, Fireplace Dimensions

Page 7

SPECIFICATIONS

 

DVP42

DVP48

Input Btu/hr Maximum

28,000

30,000

Btu/hr Minimum (millivolt only)

19,000

20,500

KWH (Maximum)

8.2

8.8

(Minimum)

5.5

6.0

NAT.

 

 

Orifice

#38 (.1015)

#37 (.1040) P-213

P-203

 

 

Air Shutter Opening

1/8"(3.2mm)

1/8"(3.2mm)

LP

 

 

Orifice

#52 (.0635")

1.65MM

P-213

P-250

 

Air Shutter Opening

FULL OPEN

FULL OPEN

Height without standoff

34 3/4"(3.2mm)

34 3/4"(3.2mm)

Width

43"(1092mm)

49"(1245mm)

Depth

19 7/8"(505mm)

19 7/8"(505mm)

Gas Inlet Shutoff Valve (Pipe)

1/2 NPT

1/2 NPT

NOTE: Air shutter settings are factory minimum settings. Some venting configurations may require minor air shutter adjustments for optimum performance.

Venting Options

Description

DVVK-5TS

TOP VENT KIT (HORZ.) - 4½" to 6" wall

 

thickness (114.3mm to 152mm)

DVVK-5T

top vent kit (horz.) - 8" to 12" wall thickness

 

(203mm to 305mm)

DVVK-5R

rear vent kit (horz.) - 5" to 7" wall thickness

 

(203mm to 305mm)

DVVK-5V

VERTICAL vent kit

DVVK-5F

HORIZONTAL FLEX VENT KIT (4' FLEX)

 

(1.22M)

Remote Control Options &

Description

Accessories

 

FRBC

Millivolt Batt. Remote ON/OFF

FRBTC

Millivolt Batt. Remote T-Stat

TMW

Millivolt WIRELESS Wall Thermostat

TRW

Millivolt REED SWITCH Wall Thermostat

FWS-1

Direct Ignition/Millivolt Wall Switch

FIREPLACE DIMENSIONS

RIGHT SIDE VIEW

H

J

 

DVP42

DVP48

A

43"

49"

 

1092mm

1245mm

B

40"

46"

 

1016mm

1168mm

C

25

1/16"

25

1/16"

 

636 mm

636 mm

D

37

5/8"

37

5/8"

 

956 mm

956 mm

E

34

3/4"

34

3/4"

 

883 mm

883 mm

F

19

7/8"

19

7/8"

 

505 mm

505 mm

G

26"

26"

 

660 mm

660 mm

H

7 1/8"

7 1/8"

K

181 mm

181 mm

I

26

1/2"

32

1/2"

 

826 mm

826 mm

J

13

1/4"

16

1/4"

 

337 mm

413 mm

K

12

3/4"

12

3/4"

 

324 mm

324 mm

17375-10-0706

Figure 1

Page 7

Image 7
Contents Effective Date Millivolt Standing PilotIntermittent Pilot Remote RF ModelsMain Title Important Safety Information No Odor Detected Odor Fade LP-GAS Warning OdorSome Points to Remember Vent Directly BELOW. Keep Clear of ALL Obstructions Requirements for MassachusettsIntroduction Fireplace Dimensions SpecificationsLocating Fireplace ClearancesGAS Supply Installing a New Main Gas CockChecking Manifold Pressures Converting flue take-off to rear venting Rear Vent ConversionFraming and Finishing InstallationVent Pipe Clearance Framing Figure Flush Mount Mantel Installation FigureFinishing Figures 12 VERTICAL, 90 Elbow with Horizontal Termination Flush Wall InstallationCombustible Surround Installation Vent Runs Figures 14, 15, 16, 17Model VERTICAL, 90 Elbow to Horizontal OUT the WallExample B Venting Fireplace TOPTo Use the Vent Graph Figure Example aTypical Basement Installation Below Grade InstallationCutting the Hole Figures Positioning the FireplaceExamples TOP Vent RUN Venting Fireplace Rear Dimensions in FeetExamples Rear Vent RUN Termination Clearances Vertical Sidewall InstallationsInformation on Various Venting Routes and Components Vent Clearances Vent System Identification Installing Vent Components FigureFraming and Finishing Installing Support Brackets FigureSee Horizontal Termination Page 25 and Vertical Termination Horizontal TerminationDVVK-5F Flex Vent Instructions InstallationDetermining Minimum Vent Height Above the Roof General MaintenanceInstalling the Vent System in a Chase Vertical TerminationVertical Termination Reassembly and Resealing Vent Pipe SystemLOG Placement 3 LOG SET Pilot Flame Figure Operating InstructionsMillivolt System Initial LightingTRW Standing Pilot Wiring Diagram Standing Pilot Lighting Instructions For Your SAFETY, Read Before LightingGlass soots Standing Pilot TroubleshootingFrequent pilot outage problem Pilot and main burner extinguish while in operationIntermittent Pilot Operating Instructions Intermittent Pilot Wiring DiagramElectrical Connection Figure Damage, personal injury or loss of life Intermittent Pilot Lighting InsturctionsOperation Intermittent Pilot TroubleshootingS8600H Intermittent Ignition Module Specifications CheckoutMain Burner Operation Safety LockoutIgnition System Checks Check ignition cable. Make sure ARC Length ActionIntermittent Pilot Troubleshooting RF Standing Pilot Operating Instructions Status Action RF Transmitter FunctionsRF Wiring Diagram Wiring Diagram with BlowerWhat to do if YOU Smell GAS RF Standing Pilot Lighting InstructionsMaintenance and Service Parts View Index Part Number Description DVP42 DVP48 Parts ListParts List Blower Motor FBB4 Optional Variable Speed Blower InstallationBlower Wheels Volt AC Optional Brick Liner Installation Instructions Junction BOX Wiring Installation InstructionsFBB4 AccessoriesService Notes HOW to Order Repair Parts Service Notes Service Notes 17375-10-0706

DVP42FP3(0,1,2,3)(N,P)-1, DVP42FP9(1,3)(N,P)-1, DVP48FP7(0,1,2,3)(N,P)-1, DVP48FP3(0,1,2,3)(N,P)-1, DVP48FP9(1,3)(N,P)-1 specifications

Empire Comfort Systems is a well-established name in the heating and comfort industry, and their line of direct vent gas fireplaces is a testament to their commitment to quality, efficiency, and innovative design. Among their offerings, models such as the DVP42FP9(1,3)(N,P)-1, DVP42FP7(0,1,2,3)(N,P)-1, DVP48FP9(1,3)(N,P)-1, DVP48FP7(0,1,2,3)(N,P)-1, and DVP42FP3(0,1,2,3)(N,P)-1 stand out for their remarkable features and technologies.

One of the key characteristics of these models is their direct vent technology, which allows them to draw in air from outside for combustion while venting exhaust safely outside. This feature enhances safety and efficiency, making them suitable for a variety of home environments. The models are equipped with adjustable flame control, allowing users to customize the ambiance according to their preferences, whether they seek a cozy, intimate setting or a more vibrant and warm atmosphere.

The DVP series is designed for easy installation and flexibility in placement, offering venting options that can accommodate different room layouts. The fireplaces feature easy-to-use electronic ignitions, alongside manual controls, ensuring reliability and ease of operation. Furthermore, the units are compatible with both natural gas and propane, providing versatility depending on the homeowner's fuel preferences.

Another crucial aspect of these models is their focus on energy efficiency. With advanced combustion systems, they maximize heat output while minimizing gas consumption, making them an environmentally friendly option. The fireplaces produce a significant amount of BTUs, providing adequate heating for various room sizes, while also featuring efficient heat distribution systems that ensure warmth reaches every corner.

Aesthetic appeal is not compromised with the DVP series. These fireplaces come with a variety of attractive front designs, media options such as logs or crystals, and customizable trim finishes. This versatility allows homeowners to select a unit that complements their interior décor seamlessly.

In summary, Empire Comfort Systems' DVP42FP9, DVP42FP7, DVP48FP9, DVP48FP7, and DVP42FP3 models boast advanced technologies, energy efficiency, and aesthetic versatility. Each unit embodies comfort and modernity, making them an excellent addition to any home looking to enhance its heating solution while maintaining an elegant and welcoming atmosphere. With a focus on safety, user-friendliness, and design, these direct vent gas fireplaces continue to set a standard in the heating industry.