Vermont Casting DVRT41 manual Operating Instructions

Page 23

DVRT41Direct Vent Gas Fireplace

Operating Instructions

Glass Information

Only glass approved by CFM Specialty Home Products should be used on this fireplace.

The use of any non-approved replacement glass will void all product warranties.

Care must be taken to avoid breakage of the glass.

Do not operate appliance with glass front removed, cracked or broken.

Replacement glass (complete with gasket) is available through your CFM Specialty Home Products dealer and should only be installed by a licensed qualified service person.

Louvre Removal

Window Frame

Assembly

Fireplace

Front

Clamps

Glass

Panel

Glass

Panel

Pull

Clamp Hook

Push

Clamp Handle

FP771

To remove louvre assembly top, pull louvre up and then lift out. The louvre assembly bottom is hinged at the bottom edge and swings down. (Fig. 45)

2.

1.Louvre

Glass Panel

FP444

Fig. 45 Remove louvre assembly top.

Fig. 46 Window frame assembly removal.

Glass Cleaning

It is necessary to clean the glass periodically. During start-up condensation, which is normal, forms on the inside of the glass and causes lint, dust and other airborne particles to cling to the glass surface. Also initial paint curing may deposit a slight film on the glass. It is therefore recommended the glass be cleaned two or three times with a non-ammonia household cleaner and warm water (gas fireplace glass cleaner is recommended). After the initial cleaning process the glass should be cleaned two or three times during each operating season depending on the environment in the house.

Window Frame Assembly Removal

1.Turn the fireplace OFF (including the pilot).

2.If the unit has been operating, allow time for the components to cool.

3.Remove louvre assembly top.

4.Open the louvre assembly bottom.

5.Release the two clamps along lower edge of the frame by pulling down on clamp handles. (Fig. 46)

6.Tilt window frame assembly out slightly at the bottom, lift the frame up and away from the fireplace.

7.To replace window frame assembly reverse proce- dure.

Clean the glass after the first two weeks of operation.

Do not clean glass when hot. Do not use abrasive cleaners. Do not strike or slam the glass.

Replacement Of

Ceramic Hearth Panels

1.Remove glass.

2.Remove two (2) screws securing grate to hearth pan. (Fig. 47)

3.Set left and right panels on hearth and bring towards front of unit.

4.Replace grate assembly.

10006740

23

Image 23
Contents Direct Vent Model DVRT41 Table of Contents Locating Your Fireplace Installation & Operating InstructionsFraming Dimensions Fireplace Dimensions Installed as Top VentFireplace Dimensions Installed as Rear Vent Hearth Mantel ChartClearance to Combustibles MantelsGas Inlet and Manifold Pressures Gas SpecificationsGas Line Installation Framing And FinishingEB-1 Electrical Box Alternate Switch LocationRemote ON/OFF Switch Installation EB-1 receptacle Optional Top Vent ApplicationLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2Flex Vent Pipes Canadian InstallationsUSA Installations General Information Assembling Vent PipesRear Wall Vent Application How to Use the Vent GraphTwist Lock Pipes Step Rear Wall Vent InstallationVertical Sidewall Application Rear Wall Vent Installations Flex Vent PipeMaximum vent run with elbows Total angular variation 270Always install horizontal venting on a level plane Vertical Sidewall Installation Twist Lock PipeStep Vertical Sidewall Installation Flex Vent PipeVertical Through-the-Roof Application Below Grade InstallationPlace firestop spacers and secure Vertical Through-the-Roof InstallationTypical Roof SupportTypical Ceiling ApplicationSupport Venting Components Operating Instructions Flame & Temperature Adjustment Installation of LogsLog Identification Chart Burner Lava Rock PlacementSIT 820 Valve Flame CharacteristicsInspecting the Venting System To Turn Off Gas To Heater Lighting and Operating InstructionsTurning Off the Gas to the Appliance Lighting & Operating InstructionsLighting Instructions Instructions for RF Comfort Control Valve Shut Off ProcedureTransmitter Operation Off Mode On Manual ModeChange Between F/C Temperature Units Delay Timer ModeAuto Mode Fan Override During Auto ModeAuto Path LED Count Service ActionOn Path Local PathWindow Frame Assembly to be Removed Before Service Work Troubleshooting Honeywell VS8421SIT Nova 820 Millivolt Valve Trouble Shooting the Gas Control SystemSIT 822 Valve with a Honeywell Electronic Igniter Troubleshooting the Gas Control SystemNova SIT820 Valve Burner and Pilot Orifice ConversionLogs may be hot Installation PrecautionsConversion Procedure Depressd and turn center plunger Burner and Burner Compartment MaintenanceCleaning the Standing Pilot Control System Logs May Be HOTDVRT41 Description DVRT41DVRT41 LP to Natural Gas Fuel Conversion Kits Natural Gas to LPHard Direct Wire Hook Up Optional Accessories AvailableFK12 Fan Assembly FK24 Fan AssemblyDecorative Frame Trim Remote ControlsCeramic Refractory Panels Decorative Bay WindowsConversion Instructions For Use in Mobile Homes Model DVRT41RMH9b.Units with Honeywell valve Limited Lifetime Warranty State % Fireplace Efficiency % Fan-OFF Fan-ON Efficiency RatingsModel EnerGuide Ratings

DVRT41 specifications

The Vermont Casting DVRT41 is a remarkable gas fireplace that harmoniously combines contemporary aesthetics with advanced heating technology. Designed to enhance any living space, the DVRT41 stands out with its impressive features and functionality, making it a popular choice for those looking to elevate their home environment.

One of the most notable features of the DVRT41 is its efficient heat output. With an impressive BTU range, this fireplace can warm spaces effectively while maintaining low emissions. This efficiency is complemented by Vermont Castings' commitment to sustainability, ensuring that the DVRT41 aligns with environmental considerations.

Aesthetically, the DVRT41 offers a customizable experience. Consumers can choose from various faceplate designs, glass door styles, and finishes to match any décor. The fireplace’s large viewing area provides an unobstructed view of the flames, creating a cozy atmosphere that’s perfect for gatherings or quiet evenings.

The DVRT41 incorporates advanced technologies aimed at maximizing user experience. The fireplace features an intuitive remote control for convenience, allowing users to adjust flame height and heat output easily. This adaptability ensures that homeowners can create the perfect ambiance at any time. The ignition system is designed for reliability and ease, ensuring that starting the fireplace is hassle-free, even in challenging conditions.

Safety is a top priority with the DVRT41. The unit includes features such as a safety shut-off system and a tempered glass front to prevent accidental burns. Additionally, the design allows for efficient venting, minimizing the risk of backdraft or buildup of harmful gases.

Maintenance is straightforward, thanks to the unit's design. The DVRT41 is constructed with durable materials that resist corrosion and wear, ensuring longevity and reduced upkeep costs. Regular cleaning is simple, ensuring that the fireplace remains functional and beautiful for years to come.

Overall, the Vermont Casting DVRT41 gas fireplace is not only a source of warmth but also a stunning focal point within any home. Its blend of efficiency, safety, and design flexibility make it a top choice for homeowners seeking an effective heating solution that doesn’t compromise on style or substance. The DVRT41 exemplifies Vermont Castings' commitment to quality, ensuring that every unit delivers exceptional performance and aesthetic appeal.