1/2” Gas Supply

1/2” NPT x 3/8” Flare Shut-off

Valve

3/8” Flex Line (from valve)

FP297a

Fig. 6 Typical gas supply installation.

Always check for gas leaks with a mild soap and water solution applied with a brush no larger than 1” (25mm). Never apply soap and water solution with a spray bottle. Do not use an open flame for leak testing.

The fireplace valve must not be sub- jected to any test pressures exceeding 1/2 psi. Isolate or disconnect this or any other gas appliance control from the gas line when pressure testing.

The gas control is equipped with a captured screw type pressure test point, therefore it is not necessary to provide a 1/8" test point up stream of the control.

When using copper or flex connector use only ap- proved fittings. Always provide a union when using black iron pipe so that the gas line can be easily disconnected for burner or fan servicing. (Fig. 6) See the gas specifications for pressure details and ratings.

 

Remote

 

ON/OFF

 

Switch

 

TPTH

 

TP

 

TH

 

FP1218

Fig. 7

Remote switch wiring diagram for R models.

Alternate Switch Location

The remote switch can be installed on either side of the access door. Mount the switch to the switch bracket provided. Screw the bracket on either side of the frame, line up the screws with the prepunched holes. (Fig. 8)

 

FP1024

Fig. 8

Alternate switch location.

Remote ON/OFF Switch Installation

Do not wire the remote ON/OFF wall switch for this gas appliance into a 120v power supply.

1.Thread wire through the electrical knockout located on either side of the unit. Take care not to cut the wire or insulation on metal edges. Ensure the wire is secured and protected from possible damage. Run one end of the gas control valve and the other end to the conveniently located wall switch.

2.Attach the wire to the ON/OFF switch and install switch into receptacle box. Attach cover plate to switch.

3.Connect wiring to gas valve. (Fig. 7)

EB-1 Electrical Box

The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code.

For USA installations, follow the local codes and the national Electrical Code ANSI/NFPA No. 70.

It is strongly suggested that the wiring of the EB-1 Electrical Junction Box be carried out by a licensed electrician.

Ensure that the power to the supply line has been disconnected before commenc- ing this procedure.

8

10006740

Image 8
Contents Direct Vent Model DVRT41 Table of Contents Installation & Operating Instructions Locating Your FireplaceFireplace Dimensions Installed as Top Vent Framing DimensionsFireplace Dimensions Installed as Rear Vent Mantel Chart Clearance to CombustiblesMantels HearthGas Specifications Gas Line InstallationFraming And Finishing Gas Inlet and Manifold PressuresEB-1 Electrical Box Alternate Switch LocationRemote ON/OFF Switch Installation Optional Top Vent Application EB-1 receptacleGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationCanadian Installations USA InstallationsGeneral Information Assembling Vent Pipes Flex Vent PipesRear Wall Vent Application How to Use the Vent GraphTwist Lock Pipes Rear Wall Vent Installation StepRear Wall Vent Installations Flex Vent Pipe Vertical Sidewall ApplicationTotal angular variation 270 Maximum vent run with elbowsVertical Sidewall Installation Twist Lock Pipe Always install horizontal venting on a level planeVertical Sidewall Installation Flex Vent Pipe StepBelow Grade Installation Vertical Through-the-Roof ApplicationVertical Through-the-Roof Installation Place firestop spacers and secureTypical Roof SupportTypical Ceiling ApplicationSupport Venting Components Operating Instructions Installation of Logs Log Identification ChartBurner Lava Rock Placement Flame & Temperature AdjustmentSIT 820 Valve Flame CharacteristicsInspecting the Venting System Lighting and Operating Instructions To Turn Off Gas To HeaterTurning Off the Gas to the Appliance Lighting & Operating InstructionsLighting Instructions Shut Off Procedure Transmitter Operation Off ModeOn Manual Mode Instructions for RF Comfort Control ValveDelay Timer Mode Auto ModeFan Override During Auto Mode Change Between F/C Temperature UnitsLED Count Service Action Auto PathLocal Path On PathTroubleshooting Honeywell VS8421 Window Frame Assembly to be Removed Before Service WorkTrouble Shooting the Gas Control System SIT Nova 820 Millivolt ValveTroubleshooting the Gas Control System SIT 822 Valve with a Honeywell Electronic IgniterBurner and Pilot Orifice Conversion Nova SIT820 ValveLogs may be hot Installation PrecautionsConversion Procedure Depressd and turn center plunger Maintenance Cleaning the Standing Pilot Control SystemLogs May Be HOT Burner and Burner CompartmentDVRT41 DVRT41 DescriptionDVRT41 Fuel Conversion Kits Natural Gas to LP LP to Natural GasOptional Accessories Available FK12 Fan AssemblyFK24 Fan Assembly Hard Direct Wire Hook UpRemote Controls Ceramic Refractory PanelsDecorative Bay Windows Decorative Frame TrimFor Use in Mobile Homes Model DVRT41RMH Conversion Instructions9b.Units with Honeywell valve Limited Lifetime Warranty State % Fireplace Efficiency % Fan-OFF Fan-ON Efficiency RatingsModel EnerGuide Ratings

DVRT41 specifications

The Vermont Casting DVRT41 is a remarkable gas fireplace that harmoniously combines contemporary aesthetics with advanced heating technology. Designed to enhance any living space, the DVRT41 stands out with its impressive features and functionality, making it a popular choice for those looking to elevate their home environment.

One of the most notable features of the DVRT41 is its efficient heat output. With an impressive BTU range, this fireplace can warm spaces effectively while maintaining low emissions. This efficiency is complemented by Vermont Castings' commitment to sustainability, ensuring that the DVRT41 aligns with environmental considerations.

Aesthetically, the DVRT41 offers a customizable experience. Consumers can choose from various faceplate designs, glass door styles, and finishes to match any décor. The fireplace’s large viewing area provides an unobstructed view of the flames, creating a cozy atmosphere that’s perfect for gatherings or quiet evenings.

The DVRT41 incorporates advanced technologies aimed at maximizing user experience. The fireplace features an intuitive remote control for convenience, allowing users to adjust flame height and heat output easily. This adaptability ensures that homeowners can create the perfect ambiance at any time. The ignition system is designed for reliability and ease, ensuring that starting the fireplace is hassle-free, even in challenging conditions.

Safety is a top priority with the DVRT41. The unit includes features such as a safety shut-off system and a tempered glass front to prevent accidental burns. Additionally, the design allows for efficient venting, minimizing the risk of backdraft or buildup of harmful gases.

Maintenance is straightforward, thanks to the unit's design. The DVRT41 is constructed with durable materials that resist corrosion and wear, ensuring longevity and reduced upkeep costs. Regular cleaning is simple, ensuring that the fireplace remains functional and beautiful for years to come.

Overall, the Vermont Casting DVRT41 gas fireplace is not only a source of warmth but also a stunning focal point within any home. Its blend of efficiency, safety, and design flexibility make it a top choice for homeowners seeking an effective heating solution that doesn’t compromise on style or substance. The DVRT41 exemplifies Vermont Castings' commitment to quality, ensuring that every unit delivers exceptional performance and aesthetic appeal.